Siemens SIMATIC NET RUGGEDCOM RX1512 Installation Manual

Siemens SIMATIC NET RUGGEDCOM RX1512 Installation Manual

Rugged multi service platforms
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RX1512:

Quick Links

Installation Manual
SIMATIC NET
Rugged Multi Service Platforms
RUGGEDCOM RX1512
Edition
04/2021
https://www.siemens.com
Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET RUGGEDCOM RX1512

  • Page 1 Installation Manual SIMATIC NET Rugged Multi Service Platforms RUGGEDCOM RX1512 Edition 04/2021 https://www.siemens.com...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Multi Service Platforms RUGGEDCOM RX1512 Modules Technical Specifications Installation Manual Certification 04/2021 C79000-G8976-1057-20...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing Documentation ....................... v Registered Trademarks ......................v Warranty ..........................vi Training ..........................vi Customer Support ........................vi Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................1 Description ......................1 Required Tools and Materials ................. 3 Decommissioning and Disposal ................3 Cabling Recommendations ..................
  • Page 5 Table of Contents Power Supply Specifications ................33 Failsafe Relay Specifications ................33 Operating Environment ..................33 Mechanical Specifications ..................34 Dimension Drawings ................... 34 Certification ......................... 37 Approvals ......................37 6.1.1 TÜV SÜD ......................37 6.1.2 European Union (EU) ..................37 6.1.3 FCC ........................
  • Page 6: Preface

    Siemens Customer Support. Registered Trademarks RUGGEDCOM®, ROS®, RCDP®, and RUGGEDCOM Discovery Protocol® are registered trademarks of Siemens Canada Ltd. Linux® is the registered trademark of Linus Torvalds in the United States and other countries. The registered trademark Linux® is used pursuant to a sublicense from LMI, the exclusive licensee of Linus Torvalds, owner of the mark on a world-wide basis.
  • Page 7: Warranty

    Preface Warranty Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 8: Contacting Siemens

    Call a local hotline center to submit a Support Request (SR). To locate a local hotline center, visit https://w3.siemens.com/aspa_app/?lang=en. Mobile App Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: •...
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM RX1512 Installation Manual, 04/2021, C79000-G8976-1057-20...
  • Page 10: Introduction

    Introduction The RUGGEDCOM RX1512 is a cost-efficient, rugged Layer 3 switch and router. The RUGGEDCOM RX1512’s modular and field replaceable platform can be equipped with WAN, serial, and Ethernet options, making it ideally suited for electric power utilities, the industrial plant floor, and traffic control systems. The appliance’s compact form factor makes it ideal for pole mount applications or installation in restricted spaces.
  • Page 11 Introduction 1.2 Description Utility USB Port RS232 Serial Console Port (RJ45) Lamp Test/Alarm Cut-Off (LT/ACO) Button Management Port Compact Flash Card Port Alarm Indicator LED Power Status LEDs Port Status LEDs Figure 1.1 RUGGEDCOM RX1512 Management Port This 10/100Base-T Ethernet port is used for system management that is out-of-band from the switch fabric.
  • Page 12: Required Tools And Materials

    Recycling and disposal must be done in accordance with local regulations. Cabling Recommendations Siemens recommends using SIMATIC NET industrial Ethernet shielded cables for all Ethernet ports. RUGGEDCOM RX1512 Installation Manual, 04/2021, C79000-G8976-1057-20...
  • Page 13: 1.5.1 Protection On Twisted-Pair Data Ports

    Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 14: Installing The Device

    Installing the Device This chapter describes how to install the device, including mounting the device, connecting power, and connecting the device to the network. DANGER Electrocution hazard – risk of serious personal injury and/or damage to equipment. Before performing any maintenance tasks, make sure all power to the device has been disconnected and wait approximately two minutes for any remaining energy to dissipate.
  • Page 15: General Procedure

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 16: Mounting The Device

    2.3 Mounting the Device Verify all items are included. Note If any item is missing or damaged, contact Siemens for assistance. Mounting the Device The RUGGEDCOM RX1512 is designed for maximum mounting and display flexibility. It can be equipped with connectors that allow it to be installed in a 35 mm (1.4 in) DIN rail, or directly on a panel.
  • Page 17: 2.3.2 Mounting The Device To A Panel

    Installing the Device 2.3.2 Mounting the Device to a Panel To mount the device to a DIN rail, do the following: Align the adapters with the DIN rails and slide the device into place. Panel/DIN Rail Adapter DIN Rail Screw Figure 2.1 DIN Rail Mounting Install one of the supplied screws on either side of the device to secure the adapters to the DIN rails.
  • Page 18: Connecting The Failsafe Alarm Relay

    Installing the Device 2.4 Connecting the Failsafe Alarm Relay To mount the device to a panel, do the following: Place the device against the panel and mark the mounting holes on the panel. Screw Panel/DIN Rail Adapter Figure 2.2 Panel Mounting Prepare the mounting holes Align the device with the mounting holes and secure it to the panel.
  • Page 19: Connecting Power

    Installing the Device 2.5 Connecting Power Normally Closed Common Normally Open Figure 2.3 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RX1512 supports a single low DC power source. DANGER Electrocution hazard – risk of serious personal injury or death Make sure all power sources are off before servicing the power module terminals. Make sure the power source is off before servicing the power terminal.
  • Page 20: Connecting Low Dc Power

    Installing the Device 2.5.1 Connecting Low DC Power 2.5.1 Connecting Low DC Power To connect a low DC power supply to the device, do the following: NOTICE Electrical hazard – risk of damage to equipment Do not connect AC power cables to a 12, 24 or 48 VDC power supply terminal block. Damage to the power supply may occur.
  • Page 21 Installing the Device 2.5.1 Connecting Low DC Power Connect the power supply terminal block to the device. Surge Ground Terminal Positive (+) Terminal Chassis Ground Terminal Negative (-) Terminal Jumper Chassis Ground Connection Figure 2.4 DC Terminal Block Wiring for Positive VDC Power Supplies Surge Ground Terminal Positive (+) Terminal Chassis Ground Terminal...
  • Page 22 Installing the Device 2.5.1 Connecting Low DC Power Note For secure, reliable connections under severe shock or vibration, use M3.5 ring lugs with a maximum outer diameter of 7 mm (0.28 in). Make sure no bare metal is exposed beyond the safety cover. Connect the positive wire from the power source to the positive (+) terminal on the terminal block.
  • Page 23: Testing Dielectric Strength

    Installing the Device 2.5.2 Testing Dielectric Strength 2.5.2 Testing Dielectric Strength Before performing any dielectric strength or HIPOT (High Potential) testing on the RUGGEDCOM RX1512 in the field, do the following: NOTICE Electrical hazard – risk of damage to equipment Before testing the dielectric strength (HIPOT), remove the metal jumper. Damage to equipment may occur.
  • Page 24: Device Management

    It may cause damage to the contact pins of the RJ45 ports. For a permanent solution, use Siemens 6XV1870-3Qxxx certified cables (manufactured December 2019 or after) or equivalent. Siemens recommends using Siemens certified cables and connectors for Siemens RUGGEDCOM products.
  • Page 25 Device Management 3.1 Connecting to the Device Serial Console and Management Ports Connect a workstation directly to the serial console or management ports to access the boot-time control and RUGGEDCOM RX1512 interfaces. The serial console port provides access to RUGGEDCOM RX1512 's console interface, while the management port provides access to RUGGEDCOM RX1512's console and Web interfaces.
  • Page 26: Configuring The Device

    The following will void the warranty and potentially result in configuration data corruption/loss: • Using a CF card not approved by Siemens for use with this device • Removing the CF card in any scenario other than those described in this section...
  • Page 27 Device Management 3.3 Accessing the CompactFlash Card Inserting the CF card To insert the CF card into the device, do the following: NOTICE The device should only be powered on when the CF card is present. Make sure the device is powered down. Remove the CF card access panel.
  • Page 28 Device Management 3.3 Accessing the CompactFlash Card Remove the CF card access panel. Ejector Button CompactFlash Card Access Panel Figure 3.4 Removing the CF Card Press the ejector button to the left of the CF card and then pull the card out. Secure the CF card access panel to the chassis.
  • Page 29 Device Management 3.3 Accessing the CompactFlash Card RUGGEDCOM RX1512 Installation Manual, 04/2021, C79000-G8976-1057-20...
  • Page 30: Modules

    Modules The RUGGEDCOM RX1512 features slots for up to two field-replaceable line modules, which can be used to expand and customize the capabilities of the device to suit specific applications. A variety of modules are available, each featuring a specific type of communication port: copper Ethernet, fiber optic Ethernet, SFP, WAN, cellular modem and DDS.
  • Page 31: Available Modules

    Available Modules The following is a list of all power and line modules available for use in the RUGGEDCOM RX1512. For more information about individual modules, refer to the RUGGEDCOM RX1500 Series Modules Catalog [https://support.industry.siemens.com/ cs/ca/en/view/109747072]. Copper Ethernet Modules RUGGEDCOM RX1500PN LM CG01...
  • Page 32 Modules 4.2 Available Modules RUGGEDCOM RX1500PN LM 4TX03 Specifications Article Numbers Ports: 4 6GK6015-0AL20-0PC0 (Standard) Speed: 100 Mbps 6GK6015-0AL20-0PC1 Interface: TX (Conformal Coated) Port Type: M12 (4-Pin, A-Coded) Distance: 100 m (328 ft) RUGGEDCOM RX1500PN LM 4TX03B Specifications Article Numbers Ports: 4 6GK6015-0AL20-0PF0 (Standard) Speed: 100 Mbps...
  • Page 33 Modules 4.2 Available Modules Ports: 4 Port Type: LC Distance: 2 km (1.2 mi) RUGGEDCOM RX1500PN LM FL01 Specifications Article Numbers Mode: MM 6GK6015-0AL20-0BD0 (Standard) Speed: 10/100 Mbps 6GK6015-0AL20-0BD1 Interface: FL/SX (Conformal Coated) Wavelength: 820 nm Ports: 3 Port Type: ST Distance: 2 km (1.2 mi) RUGGEDCOM RX1500PN LM FG03 Specifications...
  • Page 34 Modules 4.2 Available Modules Ports: 2 Port Type: LC Distance: 2 km (1.2 mi) RUGGEDCOM RX1500PN LM 6FX50 Specifications Article Numbers SFP Sockets: 6 6GK6015-0AL20-0JD0 (Standard) Speed: 100 Mbps 6GK6015-0AL20-0JD1 (Conformal Coated) RUGGEDCOM RX1500PN LM 6FX51 Specifications Article Numbers Mode: MM 6GK6015-0AL20-0BK0 (Standard) Speed: 100 Mbps...
  • Page 35 Modules 4.2 Available Modules Speed: 56 kbps (Master/ 6GK6015-0AL20-0LB0 Slave) or 64 kbps (Standard) (Slave) 6GK6015-0AL20-0LB1 Ports: 1 (Conformal Coated) Port Type: RJ48S Cellular Modem Modules RUGGEDCOM RX1500PN LM W11 Specifications Article Numbers Services: GSM/EDGE/ 6GK6015-0AL20-0WB0 HSPA+ (Standard) Region: North America 6GK6015-0AL20-0WB1 (AT&T) (Conformal Coated)
  • Page 36 Modules 4.2 Available Modules Antennas: 2 x EVDO Rev A, 2 x Receive Diversity (Secondary) SIM: Dual Mini-SIM (2FF) RUGGEDCOM RX1500PN LM W32 Specifications Article Numbers Services: EVDO Rev A 6GK6015-0AL20-0WF0 (Standard) Region: North America (Verizon) 6GK6015-0AL20-0WF1 (Conformal Coated) Port Type: 50 Ω SMA Antennas: 1 x GSM/ EDGE/HSPA+, 1 x EVDO Rev A, 2 x Receive...
  • Page 37 Modules 4.2 Available Modules SIM: Dual Mini-SIM (2FF) RUGGEDCOM RX1500PN LM W81 Specifications Article Numbers Services: 4G LTE/HSPA+/ 6GK60150AL200WK0 EDGE/GPRS/GSM/UMTS/ (Standard) GNSS 6GK60150AL200WK1 Region: Asia-Pacific (Conformal Coated) Port Type: 50 Ω SMA Antennas: 1 x LTE Main, 1 x LTE MIMO, 1 x GPS SIM: Dual Mini-SIM (2FF) RUGGEDCOM APE Modules...
  • Page 38 Modules 4.2 Available Modules RUGGEDCOM RX1500PN LM APE1404 Specifications Article Numbers (Obsolete) Operating System: 6GK6015-0AL20-0GD0 Debian Linux® (Standard) Processor: Intel Atom 6GK6015-0AL20-0GD1 E660T 1.3 GHz, 512 KB (Conformal Coated) L2 Cache RAM: 2 GB DDR2, 800 MHz, 32-bit Disk: 16 GB SATA, Solid State Networking: Realtek RTL8111, RJ45 Gigabit...
  • Page 39: Installing/Removing Line Modules

    Modules 4.3 Installing/Removing Line Modules Video: Intel 4108 Graphics Processor, DVI- RUGGEDCOM RX1500PN LM APE1404CKP Specifications Article Numbers (Obsolete) Operating System: 6GK6015-0AL20-0GF0 Check Point GAiA™ OS (Standard) Processor: Intel Atom 6GK6015-0AL20-0GF1 E660T 1.3 GHz, 512 KB (Conformal Coated) L2 Cache RAM: 2 GB DDR2, 800 MHz, 32-bit Disk: 16 GB SATA, Solid State...
  • Page 40 Modules 4.3 Installing/Removing Line Modules NOTICE Electrical hazard – risk of power failure Do not install more than one RUGGEDCOM APE module. Installing more than one of this type of module can lead to power fluctuations and irregular shut downs. NOTICE Contamination hazard –...
  • Page 41 Modules 4.3 Installing/Removing Line Modules Installing a Module To install a line module, do the following: [Optional] If the device is installed in a rack, remove it from the rack. Remove the current module from the slot. Insert the new module into the slot. Module Chassis Screw...
  • Page 42: Technical Specifications

    Technical Specifications This section provides important technical specifications related to the device. Power Supply Specifications Note When determining cable lengths, make sure the minimum input voltage for the power supply is provided at the power source. Power Input Range Internal Maximum Power Supply Type Fuse Rating...
  • Page 43: Mechanical Specifications

    Technical Specifications 5.4 Mechanical Specifications Ambient Relative Humidity 5% to 95% Maximum Altitude 2000 m (6562 ft) Measured from a 30 cm (12 in) radius surrounding the center of the enclosure. Operating temperature may vary based on the limitations of installed SFPs. Refer to the RUGGEDCOM SFP Transceivers Catalog for SFP temperature ratings.
  • Page 44 Technical Specifications 5.5 Dimension Drawings 111.8 Figure 5.1 Overall Dimensions RUGGEDCOM RX1512 Installation Manual, 04/2021, C79000-G8976-1057-20...
  • Page 45 Technical Specifications 5.5 Dimension Drawings 160.5 152.4 150.4 78.2 Figure 5.2 Panel and Din Rail Mount Dimensions 162.5 151.4 19.7 Figure 5.3 Line Module Dimensions 162.5 151.8 40.6 Figure 5.4 Power Module Dimensions RUGGEDCOM RX1512 Installation Manual, 04/2021, C79000-G8976-1057-20...
  • Page 46: Certification

    UL 62368-1 Information Technology Equipment – Safety – Part 1: General Requirements 6.1.2 European Union (EU) This device is declared by Siemens AG to comply with essential requirements and other relevant provisions of the following EU directives: • Directive 2014/30/EU...
  • Page 47 The device is marked with a CE marking and notified body number, and can be used throughout the European community. 0680 A copy of the CE Declaration of Conformity is available from Siemens AG. For contact information, refer to "Contacting Siemens (Page vii)".
  • Page 48: Fcc

    Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiological Health 6.1.5 ISED This device is declared by Siemens AG to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) 6.1.6...
  • Page 49: 6.1.8 Other Approvals

    China RoHS 2 Administrative Measure on the Control of Pollution Caused by Electronic Information Products A copy of the Material Declaration is available online at https:// support.industry.siemens.com/cs/ww/en/view/109738831. 6.1.8 Other Approvals This device meets the requirements of the following additional standards: •...
  • Page 50 Signal ports 5 kV (Failsafe Relay output) DC Power Ports 5 kV Siemens-specified severity levels. EMC Immunity Type Tests for IEEE 1613 Note The RUGGEDCOM RX1512 meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Class 1 allows for temporary communication loss, while Class 2 requires error-free and interrupted communications.
  • Page 51 Certification 6.2 EMC and Environmental Type Tests Environmental Type Tests Test Description Test Levels Severity Levels IEC 60068-2-1 Cold Temperature Test Ad -40 °C (-40 °F), 16 Hours   IEC 60068-2-2 Dry Heat Test Bd 85 °C (185 °F), 16 Hours  ...
  • Page 52 Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...

This manual is also suitable for:

Ruggedcom rx1512Simatic net

Table of Contents