Honeywell Youjie HH660 User Manual

Honeywell Youjie HH660 User Manual

Area-imaging scanner
Hide thumbs Also See for Youjie HH660:
Table of Contents
Youjie HH660
Area-Imaging Scanner
User's Guide
Table of Contents
loading

Summary of Contents for Honeywell Youjie HH660

  • Page 1 Youjie HH660 Area-Imaging Scanner User’s Guide...
  • Page 2 Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made.
  • Page 3: Table Of Contents

    ® Verifone Ruby Terminal Default Settings................2-5 ® Gilbarco Terminal Default Settings ..................2-5 Honeywell Bioptic Aux Port Configuration ................2-5 © Datalogic™ Magellan Bioptic Aux Port Configuration............2-6 NCR Bioptic Aux Port Configuration ..................2-6 Wincor Nixdorf Terminal Default Settings ................2-6 Wincor Nixdorf Beetle™ Terminal Default Settings .............2-7 Wincor Nixdorf RS232 Mode A ....................2-7...
  • Page 4 Keyboard Modifiers......................2-17 RS232 Modifiers ........................ 2-18 RS232 Baud Rate......................2-18 RS232 Word Length: Data Bits, Stop Bits, and Parity ..........2-19 RS232 Receiver Time-Out................... 2-20 RS232 Handshaking....................2-20 RS232 Timeout......................2-21 XON/XOFF ........................2-21 ACK/NAK ........................2-22 Scanner to Bioptic Communication ................... 2-22 Scanner-Bioptic Packet Mode ..................
  • Page 5 Character Activation Mode ....................3-11 Activation Character ....................3-12 End Character Activation After Good Read ..............3-12 Character Activation Timeout ..................3-12 Character Deactivation Mode .................... 3-12 Deactivation Character ....................3-13 Aimer Delay ........................3-13 User-Specified Aimer Delay..................3-13 Aimer Mode ........................3-13 Centering ...........................
  • Page 6 Code 39 ..........................6-4 Code 32 Pharmaceutical (PARAF) ................6-5 Full ASCII........................6-6 Code 39 Code Page ...................... 6-6 Interleaved 2 of 5......................... 6-7 NEC 2 of 5 ........................... 6-8 Code 93 ..........................6-9 Code 93 Code Page ....................6-10 Straight 2 of 5 Industrial (three-bar start/stop)..............
  • Page 7 Trigger Commands......................8-3 Resetting the Custom Defaults.................... 8-3 Menu Commands ........................ 8-3 Chapter 9 - Product Specifications Youjie HH660 Scanner Product Specifications ..............9-1 Standard Cable Pinouts....................... 9-2 USB ..........................9-2 Chapter 10 - Maintenance and Troubleshooting Repairs ..........................10-1 Maintenance ........................
  • Page 8 Appendix A - Reference Charts Symbology Charts .......................A-1 Linear Symbologies .......................A-1 2D Symbologies......................A-2 Postal Symbologies .......................A-2 ASCII Conversion Chart (Code Page 1252)................A-3 Lower ASCII Reference Table.....................A-4 ISO 2022/ISO 646 Character Replacements ..............A-7 Unicode Key Maps ......................A-9 Sample Symbols Programming Chart...
  • Page 9: Customer Support

    For our latest contact information, see www.honeywellaidc.com/locations. Product Service and Repair Honeywell International Inc. provides service for all of its products through service centers throughout the world. To obtain warranty or non-warranty service, please visit www.honeywellaidc.com and select the Support tab to see your region's instructions on how to obtain a Return Material Authorization number (RMA #).
  • Page 10 viii...
  • Page 11: Chapter 1 - Getting Started

    Honeywell bar code scanners are factory programmed for the most common terminal and communications settings. If you need to change these settings, programming is accomplished by scanning the bar codes in this guide.
  • Page 12: Connecting With Keyboard Wedge

    Connecting with Keyboard Wedge A scanner can be connected between the keyboard and PC as a “keyboard wedge,” where the scanner provides data out- put that is similar to keyboard entries. The following is an example of a keyboard wedge connection: 1.
  • Page 13: Connecting With Rs485

    4. Once the scanner has been fully connected, power up the computer. This interface programs 115,200 baud, 8 data bits, no parity, and 1 stop bit. Connecting with RS485 A scanner can be connected for an IBM POS terminal interface. 1.
  • Page 14: Reading Techniques

    Menu Bar Code Security Settings Honeywell scanners are programmed by scanning menu bar codes or by sending serial commands to the scanner. If you want to restrict the ability to scan menu codes, you can use the Menu Bar Code Security settings. Please contact the nearest techni-...
  • Page 15: Resetting The Custom Defaults

    Resetting the Custom Defaults If you want the custom default settings restored to your scanner, scan the Activate Custom Defaults bar code below. This is the recommended default bar code for most users. It resets the scanner to the custom default settings. If there are no custom defaults, it will reset the scanner to the factory default settings.
  • Page 16 1 - 6...
  • Page 17: Chapter 2 - Programming The Interface

    Programming the Interface Introduction This chapter describes how to program your system for the desired interface. Programming the Interface - Plug and Play Plug and Play bar codes provide instant scanner set up for commonly used interfaces. Note: After you scan one of the codes, power cycle the host terminal to have the interface in effect. Keyboard Wedge If you want your system programmed for an IBM PC AT and compatibles keyboard wedge interface with a USA keyboard, scan the bar code below.
  • Page 18: Rs485

    RS485 Scan one of the following “Plug and Play” codes to program the scanner for an IBM POS terminal interface. Note: After scanning one of these codes, you must power cycle the cash register. IBM Port 5B Interface IBM Port 9B HHBCR-1 Interface IBM Port 17 Interface IBM Port 9B...
  • Page 19: Usb Ibm Surepos

    RS485 Packet Length If you are using Packet mode, you can specify the size of the data “packet” that is sent to the host. Scan the Packet Length bar code, then then the packet size (from 20 - 256) from the Programming Chart inside the back cover of this manual, then Save.
  • Page 20: Usb Hid

    Scan the following code to program the scanner to emulate a regular RS232-based COM Port. If you are using a Microsoft® Windows® PC, you will need to download a driver from the Honeywell website (www.honeywellaidc.com). The driver will use the next available COM Port number. Apple® Macintosh computers recognize the scanner as a USB CDC class device and automatically uses a class driver.
  • Page 21: Verifone ® Ruby Terminal Default Settings

    Honeywell Bioptic Aux Port Configuration Scan the following Plug and Play code to program the scanner for a Honeywell bioptic scanner auxiliary port configuration. This bar code sets the baud rate to 38400 bps and the data format to 8 data bits, no parity, 1 stop bit.
  • Page 22: Datalogic™ Magellan © Bioptic Aux Port Configuration

    © Datalogic™ Magellan Bioptic Aux Port Configuration Scan the following Plug and Play code to program the scanner for a Datalogic Magellan bioptic scanner auxiliary port configura- tion. This bar code sets the baud rate to 9600 bps and the data format to 8 data bits, no parity, 1 stop bit. Datalogic Magellan Bioptic Settings NCR Bioptic Aux Port Configuration Scan the following Plug and Play code to program the scanner for an NCR bioptic scanner auxiliary port configuration.
  • Page 23: Wincor Nixdorf Beetle™ Terminal Default Settings

    Wincor Nixdorf Beetle™ Terminal Default Settings Scan the following Plug and Play code to program the scanner for a Wincor Nixdorf Beetle terminal. This bar code sets the baud rate to 115200 bps and the data format to 8 data bits, no parity, 1 stop bit. The following prefixes are programmed for each symbology: Symbology Prefix...
  • Page 24: Keyboard Country Layout

    Keyboard Country Layout If your interface is USB Keyboard or Keyboard Wedge, your keyboard layout default is a US keyboard. To change this layout, refer to the chart below for your keyboard country. Scan the appropriate bar code below to change the layout. By default, national character replacements are used for the following characters: #$@[\]^‘{|}~ See ISO 2022/ISO 646 Character Replacements...
  • Page 25 Keyboard Countries (Continued) Bulgaria (Latin) Canada (French legacy) Canada (French) Canada (Multilingual) Croatia Czech Czech (Programmers) Czech (QWERTY) Czech (QWERTZ) Denmark Dutch (Netherlands) 2 - 9...
  • Page 26 Keyboard Countries (Continued) Estonia Faroese Finland France Gaelic Germany Greek Greek (220 Latin) Greek (220) Greek (319 Latin) Greek (319) 2 - 10...
  • Page 27 Keyboard Countries (Continued) Greek (Latin) Greek (MS) Greek (Polytonic) Hebrew Hungarian (101 key) Hungary Iceland Irish Italian (142) Italy Japan ASCII 2 - 11...
  • Page 28 Keyboard Countries (Continued) Kazakh Kyrgyz (Cyrillic) Latin America Latvia Latvia (QWERTY) Lithuania Lithuania (IBM) Macedonia Malta Mongolian (Cyrillic) Norway 2 - 12...
  • Page 29 Keyboard Countries (Continued) Poland Polish (214) Polish (Programmers) Portugal Romania Russia Russian (MS) Russian (Typewriter) Serbia (Cyrillic) Serbia (Latin) 2 - 13...
  • Page 30 Keyboard Countries (Continued) Slovakia Slovakia (QWERTY) Slovakia (QWERTZ) Slovenia Spain Spanish variation Sweden Switzerland (French) Switzerland (German) Tatar Turkey F 2 - 14...
  • Page 31: Keyboard Style

    Keyboard Countries (Continued) Turkey Q Ukrainian United Kingdom United States (Dvorak) United States (Dvorak left) United Stated (Dvorak right) United States (International) Uzbek (Cyrillic) Keyboard Style This programs keyboard styles, such as Caps Lock and Shift Lock. If you have used Keyboard Conversion settings, they will override any of the following Keyboard Style settings.
  • Page 32: Keyboard Conversion

    Shift Lock is used when you normally have the Shift Lock key on (not common to U.S. keyboards). Shift Lock Automatic Caps Lock is used if you change the Caps Lock key on and off. The software tracks and reflects if you have Caps Lock on or off .
  • Page 33: Control Character Output

    Control Character Output This selection sends a text string instead of a control character. For example, when the control character for a carriage return is expected, the output would display [CR] instead of the ASCII code of 0D. Refer to ASCII Conversion Chart (Code Page 1252) on page A-3.
  • Page 34: Rs232 Modifiers

    Turbo Mode: The scanner sends characters to a terminal faster. If the terminal drops characters, do not use Turbo Mode. Default = Off. Turbo Mode On * Turbo Mode Off Numeric Keypad Mode: Sends numeric characters as if entered from a numeric keypad. Default = Off. Numeric Keypad Mode On * Numeric Keypad Mode Off Automatic Direct Connect Mode: This selection can be used if you have an IBM AT style terminal and the system is dropping...
  • Page 35: Rs232 Word Length: Data Bits, Stop Bits, And Parity

    1200 2400 4800 9600 19200 38400 57,600 * 115,200 RS232 Word Length: Data Bits, Stop Bits, and Parity Data Bits sets the word length at 7 or 8 bits of data per character. If an application requires only ASCII Hex characters 0 through 7F decimal (text, digits, and punctuation), select 7 data bits.
  • Page 36: Rs232 Receiver Time-Out

    7 Data, 1 Stop, Parity None 7 Data, 1 Stop, Parity Odd 7 Data, 2 Stop, Parity Even 7 Data, 2 Stop Parity None 7 Data, 2 Stop, Parity Odd 8 Data, 1 Stop, Parity Even * 8 Data, 1 Stop, Parity None 8 Data, 1 Stop, Parity Odd RS232 Receiver Time-Out The unit stays awake to receive data until the RS232 Receiver Time-Out expires.
  • Page 37: Rs232 Timeout

    Two-Direction Flow Control: The scanner asserts RTS when it is OK for the host to transmit. The host asserts CTS when it is OK for the device to transmit. Flow Control with Timeout: The scanner asserts RTS when it has data to send and waits for a delay (see RS232 Timeout on page 2-21) for CTS to be asserted by the host.
  • Page 38: Ack/Nak

    Scanner to Bioptic Communication The following settings are used to set up communication between Honeywell scanners and bioptic scanners. Note: The scanner’s baud rate must be set to 38400 and the RS232 timeout must be set to 3000 in order to communicate with a bioptic scanner.
  • Page 39: Scanner-Bioptic Ack/Nak Timeout

    Scanner-Bioptic ACK/NAK Timeout This allows you to set the length (in milliseconds) for a timeout for a bioptic scanner’s ACK/NAK response. Scan the bar code below, then set the timeout (from 1-30,000 milliseconds) by scanning digits from the inside back cover, then scanning Save.
  • Page 40 2 - 24...
  • Page 41: Chapter 3 - Input/Output Settings

    Input/Output Settings Power Up Beeper The scanner can be programmed to beep when it’s powered up. Scan the Off bar code(s) if you don’t want a power up beep. Default = Power Up Beeper On - Scanner. Power Up Beeper Off - Scanner * Power Up Beeper On - Scanner...
  • Page 42: Good Read And Error Indicators

    Good Read and Error Indicators Beeper – Good Read The beeper may be programmed On or Off in response to a good read. Turning this option off, only turns off the beeper response to a good read indication. All error and menu beeps are still audible. Default = Beeper - Good Read On. Beeper - Good Read Off * Beeper - Good Read On Beeper Volume –...
  • Page 43: Beeper Pitch - Error

    High (4200 Hz) Beeper Pitch – Error The beeper pitch codes modify the pitch (frequency) of the sound the scanner emits when there is a bad read or error. Default = Razz. * Razz (250 Hz) Medium (3250 Hz) High (4200 Hz) Beeper Duration –...
  • Page 44: Number Of Beeps - Good Read

    Number of Beeps – Good Read The number of beeps of a good read can be programmed from 1 - 9. The same number of beeps will be applied to the beeper and LED in response to a good read. For example, if you program this option to have five beeps, there will be five beeps and five LED flashes in response to a good read.
  • Page 45: Manual Trigger Mode

    Manual Trigger Mode When in manual trigger mode, the scanner scans until a bar code is read, or until the trigger is released. Default = Manual Trig- ger-Normal. * Manual Trigger - Normal LED Illumination - Manual Trigger If you wish to set the illumination LED brightness, scan one of the bar codes below. This sets the LED illumination for the scanner when the trigger is pressed.
  • Page 46: Idle Illumination - Presentation Mode

    Scan the following bar code to program your scanner for Presentation Mode. Presentation Mode Idle Illumination - Presentation Mode Scan one of the bar codes below to set the LED illumination for the scanner when it is in an idle state in Presentation Mode. Default = High.
  • Page 47 In the example below, the white box is the centering window. The centering window has been set to 20% left, 30% right, 8% top, and 25% bottom. Since Bar Code 1 passes through the centering window, it will be read. Bar Code 2 does not pass through the centering window, so it will not be read.
  • Page 48: In-Stand Sensor Mode

    Left of Presentation Centering Window Right of Presentation Centering Window In-Stand Sensor Mode This feature senses when the scanner is removed from the stand and tells it to begin manual triggering. When Sensor On is enabled, the scanner defaults to Presentation Mode when it is in the stand, and to Manual Trigger Mode when it is removed from the stand.
  • Page 49: Poor Quality Pdf Codes

    Poor Quality PDF Codes This setting improves the scanner’s ability to read damaged or badly printed PDF codes by combining information from mul- tiple images. When Poor Quality PDF On is scanned, poor quality PDF code reading is improved, but the scanner’s snap- piness is decreased, making it less aggressive when reading good quality bar codes.
  • Page 50: Hands Free Time-Out

    Hands Free Time-Out The Scan Stand and Presentation Modes are referred to as “hands free” modes. If the scanner’s trigger is pressed when using a hands free mode, the scanner changes to manual trigger mode. You can set the time the scanner should remain in manual trigger mode by setting the Hands Free Time-Out.
  • Page 51: 2D Reread Delay

    2D Reread Delay Sometimes 2D bar codes can take longer to read than other bar codes. If you wish to set a separate Reread Delay for 2D bar codes, scan one of the programming codes that follows. 2D Reread Delay Off indicates that the time set for Reread Delay is used for both 1D and 2D bar codes.
  • Page 52: Activation Character

    Activation Character This sets the character used to trigger scanning when using Character Activation Mode. On the ASCII Conversion Chart (Code Page 1252), page A-3, find the hex value that represents the character you want to use to trigger scanning. Scan the following bar code, then use the Programming Chart to read the alphanumeric combination that represents that ASCII...
  • Page 53: Deactivation Character

    Deactivation Character This sets the character used to terminate scanning when using Character Deactivation Mode. On the ASCII Conversion Chart (Code Page 1252), page A-3, find the hex value that represents the character you want to use to terminate scanning. Scan the following bar code, then use the Programming Chart to read the alphanumeric combination that represents that...
  • Page 54: Centering

    Centering Use Centering to narrow the scanner’s field of view to make sure that when the scanner is hand-held, it reads only those bar codes intended by the user. For instance, if multiple codes are placed closely together, centering will insure that only the desired codes are read.
  • Page 55: No Read

    Top of Centering Window Bottom of Centering Window Left of Centering Window Right of Centering Window No Read With No Read turned On, the scanner notifies you if a code cannot be read. If using an EZConfig-Scanning Tool Scan Data Window (see page 7-2), an “NR”...
  • Page 56: Working Orientation

    Video Reverse and Standard Bar Codes * Video Reverse Off Working Orientation Some bar codes are direction-sensitive. For example, KIX codes and OCR can misread when scanned sideways or upside down. Use the working orientation settings if your direction-sensitive codes will not usually be presented upright to the scanner. Default = Upright.
  • Page 57 Vertical, Top to Bottom 3 - 17...
  • Page 58 3 - 18...
  • Page 59: Chapter 4 - Data Editing

    Data Editing Prefix/Suffix Overview When a bar code is scanned, additional information is sent to the host computer along with the bar code data. This group of bar code data and additional, user-defined data is called a “message string.” The selections in this section are used to build the user-defined data into the message string.
  • Page 60: To Clear One Or All Prefixes Or Suffixes

    Example: Add a Tab Suffix to All Symbologies Step 1. Scan Add Suffix. Step 2. Scan 9, 9 from the Programming Chart inside the back cover of this manual to apply this suffix to all symbologies. Step 3. Scan 0, 9 from the Programming Chart inside the back cover of this manual.
  • Page 61: Function Code Transmit

    Clear One Suffix Clear All Suffixes Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. Charts of these function codes are provided in Reference Charts starting on page...
  • Page 62: Interfunction Delay

    Next, scan the Character to Trigger Delay bar code, then the 2-digit hex value for a printable character to trigger the delay (see Lower ASCII Reference Table on page A-4). Delay Length Character to Trigger Delay To remove this delay, scan the Delay Length bar code, and set the number of delays to 0. Scan the Save bar code using Programming Chart inside the back cover of this manual.
  • Page 63: Chapter 5 - Data Formatting

    Data Formatting Data Format Editor Introduction You may use the Data Format Editor to change the scanner’s output. For example, you can use the Data Format Editor to insert characters at certain points in bar code data as it is scanned. The selections in the following pages are used only if you wish to alter the output.
  • Page 64: Other Programming Selections

    from the Programming Chart inside the back cover of this manual. (Note: 50 characters is entered as 0050. 9999 is a universal number, indicating all lengths.) Step 6. Editor Commands Refer to Data Format Editor Commands (page 5-3). Scan the symbols that represent the command you want to enter. Step 7.
  • Page 65: Terminal Id Table

    Terminal ID Table Terminal Model(s) Terminal ID PC keyboard (HID) Mac Keyboard PC Keyboard (Japanese) Serial (COM driver required) HID POS USB SurePOS Handheld USB SurePOS Tabletop Serial RS232 TTL RS232 True Keyboard PS2 compatibles Data Format Editor Commands Send Commands Send all characters F1 Include in the output message all of the characters from the input message, starting from current cursor position, followed by an insert character.
  • Page 66: Move Commands

    The data is output as: 1234567890 ABCDEFGHIJ Send all characters up to a particular character F3 Include in the output message all characters from the input message, starting with the character at the current cursor position and continuing to, but not including, the search character “ss,” followed by an insert character. The cursor is moved forward to the “ss”...
  • Page 67: Search Commands

    F5 Example: Move the cursor forward and send the data Move the cursor forward 3 characters, then send the rest of the bar code data from the bar code above. End with a carriage return. Command string: F503F10D F5 is the “Move the cursor forward a number of characters” command 03 is the number of characters to move the cursor F1 is the “Send all characters”...
  • Page 68 F8 Example: Send bar code data that starts after a particular character Search for the letter “D” in bar codes and send all the data that follows, including the “D.” Using the bar code above: Command string: F844F10D F8 is the “Search forward for a character” command 44 is the hex value for “D”...
  • Page 69: Miscellaneous Commands

    Miscellaneous Commands Suppress characters FB Suppress all occurrences of up to 15 different characters, starting at the current cursor position, as the cursor is advanced by other commands. When the FC command is encountered, the suppress function is terminated. The cursor is not moved by the FB command.
  • Page 70 The data is output as: 1234 5678 Stop replacing characters E5 Terminates character replacement. Syntax = E5. Compare characters FE Compare the character in the current cursor position to the character “xx.” If characters are equal, move the cursor forward one position.
  • Page 71: Data Formatter

    Insert a delay EF Inserts a delay of up to 49,995 milliseconds (in multiples of 5), starting from the current cursor position. Syntax = EFnnnn where nnnn stands for the delay in 5ms increments, up to 9999. This command can only be used with keyboard emulation.
  • Page 72 Data Format 3 5 - 10...
  • Page 73: All Symbologies

    Symbologies This programming section contains the following menu selections. Refer to Chapter 8 for settings and defaults. • All Symbologies • Interleaved 2 of 5 • Aztec Code • Korea Post • China Post (Hong Kong 2 of 5) • Matrix 2 of 5 •...
  • Page 74: Codabar

    EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the bar codes included in the explanation of the symbology, then scan the digit value of the message length and Save bar codes on the Programming Chart inside the back...
  • Page 75: Codabar Concatenation

    When Check Character is set to Validate, but Don’t Transmit, the unit will only read Codabar bar codes printed with a check character, but will not transmit the check character with the scanned data. * No Check Character Validate Modulo 16, but Don’t Transmit Validate Modulo 16 and Transmit...
  • Page 76: Code 39

    Maximum Message Length Code 39 < Default All Code 39 Settings > Code 39 On/Off * On Code 39 Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/ Stop characters.
  • Page 77: Code 32 Pharmaceutical (Paraf)

    Validate, but Don’t Transmit Validate and Transmit Code 39 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 0-48. Minimum Default = 0, Maximum Default = 48. Minimum Message Length Maximum Message Length Code 39 Append...
  • Page 78: Code 39 Code Page

    Full ASCII If Full ASCII Code 39 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #. Default = Off.
  • Page 79: Interleaved 2 Of 5

    Interleaved 2 of 5 < Default All Interleaved 2 of 5 Settings > Interleaved 2 of 5 On/Off * On Check Digit No Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit. When Check Digit is set to Validate, but Don’t Transmit, the unit only reads Interleaved 2 of 5 bar codes printed with a check digit, but will not transmit the check digit with the scanned data.
  • Page 80 Maximum Message Length NEC 2 of 5 < Default All NEC 2 of 5 Settings > NEC 2 of 5 On/Off * On Check Digit No Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit. When Check Digit is set to Validate, but Don’t Transmit, the unit only reads NEC 2 of 5 bar codes printed with a check digit, but will not transmit the check digit with the scanned data.
  • Page 81: Code 93

    NEC 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80. Minimum Message Length Maximum Message Length Code 93...
  • Page 82: Code 93 Code Page

    Code 93 Append This function allows the scanner to append the data from several Code 93 bar codes together before transmitting them to the host computer. When this function is enabled, the scanner stores those Code 93 bar codes that start with a space (excluding the start and stop symbols), and does not immediately transmit the data.
  • Page 83: Straight 2 Of 5 Industrial (Three-Bar Start/Stop)

    Straight 2 of 5 Industrial (three-bar start/stop) Straight 2 of 5 Industrial On/Off * Off Straight 2 of 5 Industrial Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information.
  • Page 84: Straight 2 Of 5 Iata (Two-Bar Start/Stop)

    Straight 2 of 5 IATA (two-bar start/stop) Straight 2 of 5 IATA On/Off * Off Straight 2 of 5 IATA Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information.
  • Page 85: Matrix 2 Of 5

    Matrix 2 of 5 Matrix 2 of 5 On/Off * Off Matrix 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information.
  • Page 86 Code 11 Code 11 On/Off * Off Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 bar codes. Default = Two Check Digits. One Check Digit * Two Check Digits Code 11 Message Length Scan the bar codes below to change the message length.
  • Page 87: Code 11

    Code 128 Code 128 On/Off * On ISBT 128 Concatenation In 1994 the International Society of Blood Transfusion (ISBT) ratified a standard for communicating critical blood informa- tion in a uniform manner. The use of ISBT formats requires a paid license. The ISBT 128 Application Specification describes 1) the critical data elements for labeling blood products, 2) the current recommendation to use Code 128 due to its high degree of security and its space-efficient design, 3) a variation of Code 128 that supports concatenation of neigh- boring symbols, and 4) the standard layout for bar codes on a blood product label.
  • Page 88: Code 128 Code Page

    Code 128 Append This function allows the scanner to append the data from several Code 128 bar codes together before transmitting them to the host computer. When the scanner encounters a Code 128 bar code with the append trigger character(s), it buffers Code 128 bar codes until it reads a Code 128 bar code that does not have the append trigger.
  • Page 89: Gs1-128

    GS1-128 GS1-128 On/Off * On GS1-128 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 1, Maximum Default = 80. Minimum Message Length Maximum Message Length UPC-A...
  • Page 90 UPC-A Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On UPC-A Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it.
  • Page 91: Upc-A/Ean-13 With Extended Coupon Code

    UPC-A Addenda Required When Required is scanned, the scanner will only read UPC-A bar codes that have addenda. You must then turn on a 2 or 5 digit addenda listed on page 6-18. Default = Not Required. Required * Not Required UPC-A Addenda Separator When this feature is on, there is a space between the data from the bar code and the data from the addenda.
  • Page 92: Coupon Gs1 Databar Output

    Coupon GS1 DataBar Output If you scan coupons that have both UPC and GS1 DataBar codes, you may wish to scan and output only the data from the GS1 DataBar code. Scan the GS1 Output On code below to scan and output only the GS1 DataBar code data. Default = GS1 Out- put Off.
  • Page 93 UPC-E0 Addenda Required When Required is scanned, the scanner will only read UPC-E bar codes that have addenda. Default = Not Required. Required * Not Required UPC-E0 Addenda Separator When this feature is On, there is a space between the data from the bar code and the data from the addenda. When turned Off, there is no space.
  • Page 94: Upc-E1

    UPC-E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC-E data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off UPC-E1 Most U.P.C.
  • Page 95: Ean/Jan-13

    EAN/JAN-13 EAN/JAN-13 On/Off * On Convert UPC-A to EAN-13 When UPC-A Converted to EAN-13 is selected, UPC-A bar codes are converted to 13 digit EAN-13 codes by adding a zero to the front. When Do not Convert UPC-A is selected, UPC-A codes are read as UPC-A. UPC-A Converted to EAN-13 * Do not Convert UPC-A EAN/JAN-13 Check Digit...
  • Page 96 EAN/JAN-13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13 data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off EAN/JAN-13 Addenda Required When Required is scanned, the scanner will only read EAN/JAN-13 bar codes that have addenda.
  • Page 97: Isbn Translate

    ISBN Translate When On is scanned, EAN-13 Bookland symbols are translated into their equivalent ISBN number format. Default = Off. * Off EAN/JAN-8 EAN/JAN-8 On/Off * On EAN/JAN-8 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On.
  • Page 98 EAN/JAN-8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-8 data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off EAN/JAN-8 Addenda Required When Required is scanned, the scanner will only read EAN/JAN-8 bar codes that have addenda.
  • Page 99: Msi

    MSI On/Off * Off MSI Check Character Different types of check characters are used with MSI bar codes. You can program the scanner to read MSI bar codes with Type 10 check characters. Default = Validate Type 10, but Don’t Transmit. When Check Character is set to Validate Type 10/11 and Transmit, the scanner will only read MSI bar codes printed with the specified type check character(s), and will transmit the character(s) at the end of the scanned data.
  • Page 100 Validate Type 11 then Type 10 Character and Transmit Disable MSI Check Characters MSI Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 4-48. Minimum Default = 4, Maximum Default = 48. Minimum Message Length Maximum Message Length 6 - 28...
  • Page 101: Gs1 Databar Omnidirectional

    GS1 DataBar Omnidirectional < Default All GS1 DataBar Omnidirectional Settings > GS1 DataBar Omnidirectional On/Off * On GS1 DataBar Limited < Default All GS1 DataBar Limited Settings > GS1 DataBar Limited On/Off * On 6 - 29...
  • Page 102: Gs1 Databar Expanded

    GS1 DataBar Expanded < Default All GS1 DataBar Expanded Settings > GS1 DataBar Expanded On/Off * On GS1 DataBar Expanded Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information.
  • Page 103: Codablock F

    Codablock A Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 1-600. Minimum Default = 1, Maximum Default = 600. Minimum Message Length Maximum Message Length Codablock F ...
  • Page 104: Pdf417

    PDF417 < Default All PDF417 Settings > PDF417 On/Off * On PDF417 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 1-2750. Minimum Default = 1, Maximum Default = 2750. Minimum Message Length Maximum Message Length MacroPDF417...
  • Page 105: Micropdf417

    MicroPDF417 < Default All MicroPDF417 Settings > MicroPDF417 On/Off * Off MicroPDF417 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 1-366. Minimum Default = 1, Maximum Default = 366. Minimum Message Length Maximum Message Length GS1 Composite Codes...
  • Page 106: Upc/Ean Version

    UPC/EAN Version Scan the UPC/EAN Version On bar code to decode GS1 Composite symbols that have a U.P.C. or an EAN linear compo- nent. (This does not affect GS1 Composite symbols with a GS1-128 or GS1 linear component.) Default = UPC/EAN Ver- sion Off.
  • Page 107: Tcif Linked Code 39 (Tlc39)

    GS1 DataBar Emulation GS1 Code Expansion Off EAN8 to EAN13 Conversion * GS1 Emulation Off TCIF Linked Code 39 (TLC39) This code is a composite code since it has a Code 39 linear component and a MicroPDF417 stacked code component. All bar code readers are capable of reading the Code 39 linear component.
  • Page 108: Qr Code Page

    QR Code Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 1-7089. Minimum Default = 1, Maximum Default = 7089. Minimum Message Length Maximum Message Length QR Code Append This function allows the scanner to append the data from several QR Code bar codes together before transmitting them to...
  • Page 109: Data Matrix

    Data Matrix < Default All Data Matrix Settings > Data Matrix On/Off * On Data Matrix Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 1-3116. Minimum Default = 1, Maximum Default = 3116. Minimum Message Length Maximum Message Length Data Matrix Append...
  • Page 110: Maxicode

    codes were created (see ISO 2022/ISO 646 Character Replacements on page A-7), and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual. The data characters should then appear properly.
  • Page 111: Aztec Code

    Aztec Code < Default All Aztec Code Settings > Aztec Code On/Off * On Aztec Code Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 1-3832. Minimum Default = 1, Maximum Default = 3832. Minimum Message Length Maximum Message Length Aztec Append...
  • Page 112: Chinese Sensible (Han Xin) Code

    codes were created (see ISO 2022/ISO 646 Character Replacements on page A-7), and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual. The data characters should then appear properly.
  • Page 113: Postal Codes - 2D

    Postal Codes - 2D The following lists the possible 2D postal codes, and 2D postal code combinations that are allowed. Only one 2D postal code selection can be active at a time. If you scan a second 2D postal code selection, the first selection is overwritten. Default = 2D Postal Codes Off.
  • Page 114: Combination 2D Postal Codes

    Postnet On Also see Postnet Check Digit, page 6-44. Postnet with B and B’ Fields On InfoMail On Combination 2D Postal Codes: InfoMail and British Post On Intelligent Mail Bar Code and Postnet with B and B’ Fields On Postnet and Postal-4i On Postnet and Intelligent Mail Bar Code On...
  • Page 115 Planet Code and Postnet with B and B’ Fields On Planet Code and Postal-4i On Planet Code and Intelligent Mail Bar Code On Planet Code, Postnet, and Postal-4i On Planet Code, Postnet, and Intelligent Mail Bar Code On Planet Code, Postal-4i, and Intelligent Mail Bar Code On Postnet,...
  • Page 116 Planet Code, Postal-4i, Intelligent Mail Bar Code, and Postnet On Planet Code, Postal-4i, Intelligent Mail Bar Code, and Postnet with B and B’ Fields On Planet Code Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of Planet Code data. Default = Don’t Transmit.
  • Page 117: Postal Codes - Linear

    Combination C and N Tables causes the field to be interpreted using either the C or N Tables. * Bar Output Numeric N Table Alphanumeric C Table Combination C and N Tables Postal Codes - Linear The following lists linear postal codes. Any combination of linear postal code selections can be active at a time. China Post (Hong Kong 2 of 5) ...
  • Page 118: Korea Post

    Maximum Message Length Korea Post Korea Post * Off Korea Post Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for addi- tional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 48. Minimum Message Length Maximum Message Length Korea Post Check Digit...
  • Page 119: Chapter 7 - Utilities

    Utilities To Add a Test Code I.D. Prefix to All Symbologies This selection allows you to turn on transmission of a Code I.D. before the decoded symbology. (See the Symbology Charts, beginning on page A-1) for the single character code that identifies each symbology.) This action first clears all current prefixes, then programs a Code I.D.
  • Page 120: Test Menu

    Note: EZConfig-Scanning requires .NET software. If .NET is not installed on your PC, you will be prompted to install it during the EZConfig-Scanning installation. 1. Access the Honeywell web site at www.honeywellaidc.com 2. Click on the Products tab. Under Software, select Device Management.
  • Page 121: Resetting The Factory Defaults

    7. Using Explorer, go to the c:\windows\temp file. 8. Double click on the Setup.exe file. Follow the screen prompts to install the EZConfig-Scanning program. 9. If you’ve selected the defaults during installation, you can click on Start Menu-All Programs-Honeywell-EZConfig- Scanning and select EZConfig for your browser.
  • Page 122 7 - 4...
  • Page 123: Chapter 8 - Serial Programming Commands

    Serial Programming Commands The serial programming commands can be used in place of the programming bar codes. Both the serial commands and the programming bar codes will program the scanner. For complete descriptions and examples of each serial programming com- mand, refer to the corresponding programming bar code in this manual.
  • Page 124: Responses

    Data Field Usage When a query is used in place of the Data field, the query applies only to the specific command identified by the Tag and SubTag fields. Concatenation of Multiple Commands Multiple commands can be issued within one Prefix/Storage sequence. Only the Tag, SubTag, and Data fields must be repeated for each command in the sequence.
  • Page 125: Trigger Commands

    the Minimum Message Length (MIN) is set to 2 characters; the Maximum Message Length (MAX) is set to 60 characters; and the Default setting (DFT) has no value. Trigger Commands You can activate and deactivate the scanner with serial trigger commands. First, the scanner must be put in Manual Trigger Mode by scanning a Manual Trigger Mode bar code (page 3-5), or by sending a serial menu command for triggering...
  • Page 126 ReM Off REMIFC0 *ReM On REMIFC1 Plug and Play Codes Verifone Ruby Terminal PAPRBY Gilbarco Terminal PAPGLB Honeywell Bioptic Aux Port PAPBIO Datalogic Magellan Bioptic Aux Port PAPMAG NCR Bioptic Aux Port PAPNCR Wincor Nixdorf Terminal PAPWNX Wincor Nixdorf Beetle...
  • Page 127 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Finland KBDCTY2 2-10 France KBDCTY3 2-10 Gaelic KBDCTY84 2-10 Germany KBDCTY4 2-10 Greek KBDCTY17 2-10 Greek (220 Latin) KBDCTY64 2-10 Greek (220) KBDCTY61 2-10 Greek (319 Latin) KBDCTY65 2-10 Greek (319)
  • Page 128 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Slovakia (QWERTY) KBDCTY49 2-14 Slovakia (QWERTZ) KBDCTY48 2-14 Slovenia KBDCTY31 2-14 Spain KBDCTY10 2-14 Spanish variation KBDCTY51 2-14 Sweden KBDCTY23 2-14 Switzerland (French) KBDCTY29 2-14 Switzerland (German) KBDCTY6 2-14 Tatar...
  • Page 129 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry 4800 BPS 232BAD4 2-19 9600 BPS 232BAD5 2-19 19200 BPS 232BAD6 2-19 38400 BPS 232BAD7 2-19 57600 BPS 232BAD8 2-19 *115200 BPS 232BAD9 2-19 Word Length: Data Bits, Stop Bits, 7 Data, 1 Stop, Parity Even 2-19 232WRD3...
  • Page 130 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Medium BEPLVL2 *High BEPLVL3 Beeper Pitch - Good Read Low (1600) (min 400Hz) BEPFQ11600 (Frequency) *Medium (2400) BEPFQ12400 High (4200) (max 9000Hz) BEPFQ14200 Beeper Pitch - Error (Frequency) *Razz (250) (min 200Hz) BEPFQ2800 Medium (3250)
  • Page 131 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Poor Quality Codes Poor Quality 1D Reading On DECLDI1 *Poor Quality 1D Reading Off DECLDI0 Poor Quality PDF Reading On PDFXPR1 *Poor Quality PDF Reading Off PDFXPR0 CodeGate *CodeGate Off Out-of-Stand AOSCGD0.
  • Page 132 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry No Read SHWNRD1 3-15 *Off SHWNRD0 3-15 Video Reverse Video Reverse Only VIDREV1 3-15 Video Reverse and Standard Bar Codes VIDREV2 3-16 *Video Reverse Off VIDREV0 3-16 Working Orientation *Upright ROTATN0...
  • Page 133 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Codabar Default All Codabar CBRDFT Settings CBRENA0 CBRENA1 Codabar Start/Stop Char. *Don’t Transmit CBRSSX0 Transmit CBRSSX1 Codabar Check Char. *No Check Char. CBRCK20 Validate, But Don’t Transmit CBRCK21 Validate, and Transmit CBRCK22...
  • Page 134 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Validate, But Don’t I25CK21 Transmit Validate, and Transmit I25CK22 Interleaved 2 of 5 Message Length Minimum (2 - 80) *4 I25MIN## Maximum (2 - 80) *80 I25MAX## NEC 2 of 5 Default All NEC N25DFT...
  • Page 135 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry *Off C11ENA0 6-14 C11ENA1 6-14 Code 11 Check Digits Required 1 Check Digit C11CK20 6-14 *2 Check Digits C11CK21 6-14 Code 11 Message Length Minimum (1 - 80) *4 C11MIN## 6-14 Maximum (1 - 80) *80...
  • Page 136 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry UPC-E0 Default All UPC-E UPEDFT 6-20 Settings UPEEN00 6-20 UPEEN01 6-20 UPC-E0 Expand *Off UPEEXP0 6-20 UPEEXP1 6-20 UPC-E0 Addenda Required Required UPEARQ1 6-21 *Not Required UPEARQ0 6-21 UPC-E0 Addenda Separator UPEADS1...
  • Page 137 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry 2 Digit Addenda On EA8AD21 6-26 *5 Digit Addenda Off EA8AD50 6-26 5 Digit Addenda On EA8AD51 6-26 EAN/JAN-8 Addenda Required *Not Required EA8ARQ0 6-26 Required EA8ARQ1 6-26 EAN/JAN-8 Addenda EA8ADS0...
  • Page 138 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Codablock F Msg. Length Minimum (1 - 2048) *1 CBFMIN#### 6-31 Maximum (1 - 2048) *2048 CBFMAX#### 6-31 PDF417 Default All PDF417 Settings PDFDFT 6-32 PDFENA1 6-32 PDFENA0 6-32 PDF417 Msg.
  • Page 139 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry MaxiCode Default All MaxiCode Settings MAXDFT 6-38 MAXENA1 6-38 *Off MAXENA0 6-38 MaxiCode Msg. Length Minimum (1-150) *1 MAXMIN### 6-38 Maximum (1-150) *150 MAXMAX### 6-38 Aztec Code Default All Aztec Code Settings AZTDFT 6-39...
  • Page 140 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Postnet with B and B’ Fields On POSTAL11 6-42 InfoMail On POSTAL2 6-42 Combination 2D Postal Codes InfoMail and British Post On POSTAL8 6-42 Intelligent Mail Bar Code and Postnet with B POSTAL20 6-42 and B’...
  • Page 141 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Resetting the Factory Defaults Remove Custom Defaults DEFOVR Activate Defaults DEFALT 8 - 19...
  • Page 142 8 - 20...
  • Page 143: Chapter 9 - Product Specifications

    Product Specifications Youjie HH660 Scanner Product Specifications Parameter Specification Mechanical Height 3.23 in. (82mm) Length 2.45 in. (62mm) Width 6.65 in. (169mm) Weight 4.6 oz. (130g) Electrical Input Voltage 4.0 - 5.5VDC Operating Power 2W (400mA @ 5VDC) Standby Power .45W (90mA @ 5VDC)
  • Page 144: Standard Cable Pinouts

    Standard Cable Pinouts Note: The following pin assignments are not compatible with Honeywell legacy products. Use of a cable with improper pin assignments may lead to damage to the unit. Use of any cables not provided by the manufacturer may result in damage not covered by your warranty.
  • Page 145 Required Safety Labels Youjie HH660 Scanner Part Number, Serial Number Label, and Revision Information location 9 - 3...
  • Page 146 9 - 4...
  • Page 147: Chapter 10 - Maintenance And Troubleshooting

    The interface cable is designed to be field replaceable. • Order replacement cables from Honeywell or from an authorized distributor. • When ordering a replacement cable, specify the cable part number of the original interface cable.
  • Page 148: Replacing A Corded Scanner Interface Cable

    Replacing a Corded Scanner Interface Cable 1. Turn the power to the host system OFF. 2. Disconnect the scanner’s cable from the terminal or computer. 3. Locate the small hole on the back of the scanner’s handle. This is the cable release. 4.
  • Page 149: Symbology Charts

    Refer to Data Editing beginning on page 4-1 and Data Formatting beginning on page 5-1 for information about using Code ID and AIM ID. Linear Symbologies Honeywell Possible modifiers Symbology All Symbologies Codabar Code 11 Code 128 0, 1, 2, 4 Code 32 Pharmaceutical (PARAF) <...
  • Page 150: 2D Symbologies

    Honeywell Possible modifiers Symbology UPC-A with Add-On UPC-A with Extended Coupon Code UPC-E UPC-E with Add-On UPC-E1 Add Honeywell Code ID 5C80 Add AIM Code ID 5C81 Add Backslash 5C5C Batch mode quantity 2D Symbologies Honeywell Possible modifiers Symbology All Symbologies...
  • Page 151: Ascii Conversion Chart (Code Page 1252

    Honeywell Possible modifiers Symbology Canadian Post China Post InfoMail Intelligent Mail Bar Code Japanese Post KIX (Netherlands) Post Korea Post Planet Code Postal-4i Postnet ASCII Conversion Chart (Code Page 1252) In keyboard applications, ASCII Control Characters can be represented in 3 different ways, as shown below. The CTRL+X func- tion is OS and application dependent.
  • Page 152: Lower Ascii Reference Table

    Non-printable ASCII control Keyboard Control + ASCII (CTRL+X) Mode characters Windows Mode Control + X Mode On (KBDCAS2) Char Control + X Mode Off (KBDCAS0) CTRL + X CTRL + X function CTRL+ X CTRL+ Y CTRL+ Z CTRL+ [ CTRL+ \ CTRL+ ] CTRL+ ^...
  • Page 153 Extended ASCII Characters CP 1252 ASCII Alternate Extended PS2 Scan Code ↑ € Ç 0x48 up arrow ↓ ü 0x50 down arrow → ‚ é 0x4B right arrow ← ƒ â 0x4D left arrow „ ä Insert 0x52 … à Delete 0x53 †...
  • Page 154 Extended ASCII Characters (Continued) CP 1252 ASCII Alternate Extended PS2 Scan Code ³ │ ´ ┤ µ ╡ ¶ ╢ · ╖ ¸ ╕ ¹ ╣ º ║ » ╗ ¼ ╝ ½ ╜ ¾ ╛ ¿ ┐ À └ Á...
  • Page 155: Iso 2022/Iso 646 Character Replacements

    (standard ASCII) Automatic National Character ISO/IEC 2022 2 (default) Replacement Binary Code page Default “Automatic National Character replacement” will select the below Honeywell Code Page options for Code128, Code 39 and Code 93. United States ISO/IEC 646-06 Canada ISO /IEC 646-121...
  • Page 156 Code Page Selection Method/Country Standard Keyboard Country Honeywell Code Page Option Germany ISO/IEC646-21 Switzerland ISO /IEC 646-CH Sweden / Finland (extended Annex C) ISO/IEC 646-11 Ireland ISO /IEC 646-207 Denmark ISO/IEC 646-08 Norway ISO/IEC 646-60 Italy ISO/IEC 646-15 Portugal ISO/IEC 646-16...
  • Page 157: Unicode Key Maps

    Unicode Key Maps 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 4B 50 55 5A 5F 64 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 4C 51 56 5B 60 65 1F 20 21 22 23 24 25 26 27 28 29...
  • Page 158 A - 10...
  • Page 159: Sample Symbols

    Sample Symbols UPC-A Interleaved 2 of 5 1234567890 0 123456 7890 EAN-13 9 780330 290951 Code 128 Code 128 Code 39 BC321 Codabar A13579B Code 93 123456-9$ Straight 2 of 5 Industrial 123456...
  • Page 160 Matrix 2 of 5 6543210 GS1 DataBar (01)00123456789012 PDF417 Car Registration Data Matrix Test Symbol QR Code Aztec Numbers Package Label MaxiCode Micro PDF417 Test Message Test Message Postnet Zip Code...
  • Page 161 4-CB (4-State Customer Bar Code) 01,234,567094,987654321,01234567891 ID-tag (UPU 4-State) J18CUSA8E6N062315014880T...
  • Page 162: Programming Chart

    Programming Chart...
  • Page 163 Programming Chart Save Discard Reset Note: If you make an error while scanning the letters or digits (before scanning Save), scan Discard, scan the correct letters or digits, and Save again.
  • Page 164 Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com YJ-HH660-UG Rev A 1/16...

Table of Contents