Hitachi SJ700 Series Manual

Powerful inverter
Hide thumbs Also See for SJ700 Series:
Powerful Inverter
Hitachi Industrial Equipment Systems Co.,Ltd.
Table of Contents
loading

Summary of Contents for Hitachi SJ700 Series

  • Page 1 Powerful Inverter Hitachi Industrial Equipment Systems Co.,Ltd.
  • Page 2 OC-Trip Motor current 0.3Hz 1200 1500 1800 -100 -200 Speed (min Hitachi original 0Hz Domain Over-current suppress OFF sensorless vector control Keep 150% * torque at 0Hz speed signal Impact load Crane applications require high torque at starting *150%torque in case 1 frame big inverter...
  • Page 3 Functions and User Friendly. Programming [EzSQ: Easy Sequence] function Inverter control by Built-in Item Description Programming function Language type BASIC Like Supported Device Windows(DOS/V)OS:Windows98SE,Windows2000,WindowsXP) 1,024 steps or 6k byte Memory area (Smaller of these)Program is stored in internal of inverter. Simple sequence operation is realized by downloading to an Editor(Windows),Display(Windows) Programming...
  • Page 4: Easy Operation

    Ease of Maintenance Easy Operation Easy-removable construction User selection of Parameter for maintenance functions Data comparison function Field replacement of cooling fan(s) and DC bus capacitor can be accomplished in a fraction of the time. Allows display of only parameters changed from default. Using Logic terminal move to SJ700 without wiring change.
  • Page 5: Environmental Friendliness

    Voltage less than 2 times of INV DC voltage E. Output frequency can be changed with UP/DOWN Function Lower than Hitachi motor Max. insulation voltage (1,250V) with analog signal as reference value. The frequency at (during regenerating operation increase the DC bus voltage may over power shutdown can be saved, too.
  • Page 6: Standard Specifications

    STANDARD SPECIFICATIONS 3-phase 200V class 3-phase 400V class Model Name Indication Model Configuration SJ700-055 H F E F 2 Applicable Applicable Motor Motor LFUF2 HFEF2 HFUF2 LFUF2 HFEF2 HFUF2 kW (HP) kW (HP) 0.4(1/2) 30(40) 0.75(1) 37(50) 1.5(2) 46(60) 2.2(3) 55(75) 3.7(5) 75(100)
  • Page 7: Specifications

    SPECIFICATIONS General Specifications Items General Specifications...
  • Page 8 DIMENSIONS SJ700-055-110 LFUF2/HFEF2, HFUF2 SJ700-150-220 LFUF2/HFEF2, HFUF2 210 (8.27) 250 (9.84) Digital Operator 189 (7.44) 0.28) 229 (9.02) Digital Operator Exhaust Exhaust 80 (3.15) 0.28) 24.5 (0.97) 80 (3.15) 24.5 (0.97) Wall Wall 7 (0.28) Air intake 189 (7.44) 3-33X28 (1.30X1.10) 7 (0.28) Wiring hole 229 (9.02)
  • Page 9: Operation And Programming

    OPERATION and PROGRAMMING SJ700 Series can be easily operated with the digital operator provided as standard. The digital operator can also be detached and can be used for remote-control. Multilingual (English, French, German, Italian , Spanish and Portuguese) operator with copy function (SRW-0EX) and digital operator with potentiometer are also available as options.
  • Page 10 TERMINALS MAIN CIRCUIT TERMINALS Terminal Description Terminal Arrangement Terminal Symbol Terminal Name 055 - 220LFUF2/HFEF2, 300 - 370LFUF2 R ( L1 ) , S ( L2 ) , T ( L3 ) Main power supply input terminals   300 - 550HFEF2, HFUF2 HFUF2 U ( T1 ) , V ( T2 ) , W ( T3 ) Inverter output terminals...
  • Page 11: Protective Functions

    PROTECTIVE FUNCTIONS PROTECTIVE FUNCTIONS ● MONITORING FUNCTIONS and MAIN PROFILE PARAMETERS × [◯ ] = Allowed = Not permitted Setting Change Default Setting Code Function Name during operation during operation Monitored data or setting -FE(CE) -FU(UL) (allowed or not) (allowed or not) ◯...
  • Page 12 × [◯ ] = Allowed = Not permitted Setting Change Default Setting Code Function Name during operation during operation Monitored data or setting -FE(CE) -FU(UL) (allowed or not) (allowed or not) × ◯ A013 O-L input active range start voltabe 0.
  • Page 13 × [◯ ] = Allowed = Not permitted Setting Setting Change Change Default Setting Default Setting Code Code Function Name Function Name during operation during operation during operation during operation Monitored data or setting Monitored data or setting -FE(CE) -FE(CE) -FU(UL) -FU(UL) (allowed or not) (allowed or not)
  • Page 14 × [◯ ] Setting Change during operation during operation (allowed or not) (allowed or not) 0.100 0.100 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ -100 -100 ○ ○ ○ ○ 255(no) 255(no) ×...
  • Page 15 × [◯ ] Setting Change during operation during operation (allowed or not) (allowed or not) × ○ × ○ ○ × × ○ × ○ × ○ × ○ × ○ × ○ 01(FA1) 01(FA1) × ○ 00(RUN) 00(RUN) × ○...
  • Page 16 × [◯ ] Setting Change during operation during operation (allowed or not) (allowed or not) 100. 100. ○ ○ ○ ○ ○ ○ × ○ ○ ○ ○ ○ ○ ○ ○ ○ × ○ × ○ × ○ × ○...
  • Page 17 × [◯ ] Setting Change during operation during operation (allowed or not) (allowed or not) × × × × 100.0 100.0 ○ ○ 100.0 100.0 ○ ○ 100.0 100.0 ○ ○ 100.0 100.0 ○ ○ 1.00 1.00 ○ ○ 1.00 1.00 ○...
  • Page 18 PROTECTIVE FUNCTIONS Display Display on remote on digital operator/copy unit Name Cause(s) operator ERR1**** OC.Drive While at constant speed The inverter output was short-circuited, or the motor shaft is locked or has a OC.Decel During deceleration heavy load. These conditions cause excessive current for the inverter, so the Over-current protection During acceleration OC.Accel...
  • Page 19: Connecting Diagram

    CONNECTING DIAGRAM Source type logic In case of 400V class, place a transformer for operating circuit to receive 200V. 200V - 240V+10%, -15% 50/60Hz±5% (T1)U SJ700 R(L1) (T2)V S(L2) (T3)W (+1)PD T(L3) DC link choke (*2)Remove connection with J51 (*2) when RoTo power is supplied T(J51) Dynamic braking unit (BRD)
  • Page 20 CONNECTING DIAGRAM Sink type logic In case of 400V class, place a transformer for operating circuit to receive 200V. 200V - 240V+10%, -15% 50/60Hz±5% (T1)U SJ700 R(L1) (T2)V S(L2) (T3)W (+1)PD T(L3) DC link choke (*2)Remove connection with J51 (*2) when RoTo power is supplied T(J51) Dynamic braking unit (BRD)
  • Page 21 SJ300 series into the SJ700 series. Copying the parameter settings (that you cannot copy the parameter settings from the SJ700 series to the SJ300 series because the SJ700 series has many new functions and additional parameters.) No display mode selection.
  • Page 22: For Correct Operation

    A max. 400Hz can be selected on the SJ700 Series. However, a two-pole motor can attain up to approx. 24,000 rpm, which is extremely dangerous.
  • Page 23 When an electromagnetic contactor is installed between the inverter and the motor, do not perform on-off switching during contactor running operation. When used with standard applicable output motors (standard three-phase squirrel-cage four-pole motors), the SJ700 Series Wiring does not need a thermal relay for motor protection due to the internal electronic protective circuit. A thermal relay, however,...
  • Page 24 Printed in Japan (T) SM-E257P 1007...