Siemens Sinteso FDSB291 Manual

Siemens Sinteso FDSB291 Manual

Sounder base, alarm sounder
Hide thumbs Also See for Sinteso FDSB291:

Quick Links

Sinteso™
Sounder base, alarm sounder
FDSB291, FDSB292, FDS221-R, FDS221-W
007026_s_en_--
2018-06-15
Addressed (FDnet), collective
Sounder base FDSB291
11 tones to choose from, 2 programmable alarm levels
Sound level up to 88 dB(A); can be set on two levels
Compatible with all addressed point detectors from the Sinteso product line
Supply and communication via FDnet
Sounder base FDSB292
One intermittent tone, one alarm level
Sound level 84 dB(A)
Compatible with neural fire detectors FDOOT241-9, FDOOT241-A9 in
collective mode
Supply via detector loop
Alarm sounders FDS221-R, FDS221-W
11 tones to choose from, 2 programmable alarm levels
Sound level up to 99 dB(A); can be set on three levels
Supply and communication via FDnet
Building Technologies
Control Products and Systems
loading

Summary of Contents for Siemens Sinteso FDSB291

  • Page 1 Sinteso™ Sounder base, alarm sounder FDSB291, FDSB292, FDS221-R, FDS221-W Addressed (FDnet), collective Sounder base FDSB291 – 11 tones to choose from, 2 programmable alarm levels – Sound level up to 88 dB(A); can be set on two levels – Compatible with all addressed point detectors from the Sinteso product line –...
  • Page 2 Properties Eco-friendly – Environmentally friendly processing – Reusable materials – Electronic parts and synthetic materials can be easily separated Sounder base FDSB291 properties – Addressed base – Adjustable sounds and sound levels, sounds synchronized for all alarm devices – Connection for an external alarm indicator –...
  • Page 3 Functions Sounder bases FDSB291, FDSB292 The sounder base FDSB291 provides an acoustic alarm in the addressed fire detection system The sounder base FDSB292 provides an acoustic alarm on a collective detector line. If the detector line is migrated to FDnet, the behavior of the sounder bases FDSB291 and FDSB292 is identical In the event of a fire alarm, the detector LED flashes and an acoustic signal sounds Alarm sounders FDS221-R, FDS221-W...
  • Page 4 Accessories Sounder base accessories Designation plate FDBZ291 For labeling with the location address Can only be used without detector base seal FDBZ295 DBZ1190-AA micro terminal and DBZ1190-AB connection terminal Micro terminal DBZ1190-AA – Cable cross section up to max. 0.5 mm² Connection terminal DBZ1190-AB –...
  • Page 5 Base attachment FDB291 Function: For routing surface-mounted cables larger than Ø 6 mm Detector base is secured with a snap fastener Designation plate FDBZ291 For labeling with the location address Can only be used without detector base seal FDBZ295 Base attachment humid FDB293 For achieving a higher protection category For mounting in wet or humid environments Required when using detector heating unit FDBH291...
  • Page 6 Protective cage DBZ1194 To protect the point detector from damage Can only be mounted in combination with the base attachment humid FDB293 or base attachment wet FDB295 DBZ1190-AA micro terminal and DBZ1190-AB connection terminal Micro terminal DBZ1190-AA – Cable cross section up to max. 0.5 mm² Connection terminal DBZ1190-AB –...
  • Page 7 009769 Technical manual Sounder base FDSB292 Related documents such as environmental declarations, CE declarations, etc., can be downloaded at the following Internet address: http://siemens.com/bt/download Notes Installation Sounder base installation Sounder bases FDSB291, FDSB292 form a single unit together with the point detector...
  • Page 8 Alarm sounder installation Insert alarm sounders FDS221-R, FDS221-W directly in the detector base and mount on walls or ceilings For recess-mounted cable entry In the case of recess-mounted cable entry for a higher IP protection category, use sealing element FDBZ295 For surface-mounted cable entry with a cable diameter of up to 6 mm with detector base FDB221.
  • Page 9 Technical data Supply FDS221-R, FDS221-W FDSB291 FDSB292 Operating voltage DC 12…33 V DC 12…33 V Operating current (quiescent) Max. 250 µA Max. 150 µA Sound activated 3.5 mA 1.2 mA Sounds 2 alarm levels 2 alarm levels 1 alarm level 3 sound levels 2 sound levels 1 sound level...
  • Page 10 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or https://siemens.com/bt/download DoP No.: 0786-CPR-20012; DoC No.: CED-FDS221 Siemens Schweiz AG;...