Siemens SIMATIC RF300 System Manual
Hide thumbs Also See for SIMATIC RF300:
1
RFID systems
SIMATIC RF300
System Manual
xx/2020
C79000-G8976-C345-08
Table of Contents
loading

Summary of Contents for Siemens SIMATIC RF300

  • Page 1 RFID systems SIMATIC RF300 System Manual xx/2020 C79000-G8976-C345-08...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    1.1.7 Ensuring reliable data exchange ..................10 1.1.8 Metal-free area ........................11 1.1.9 Minimum distance between several RF360R readers ............12 1.1.10 Technical specifications ...................... 13 1.1.11 Approvals .......................... 14 1.1.12 Dimension drawing......................16 SIMATIC RF300 System Manual, xx/2020, C79000-G8976-C345-08...
  • Page 4 Table of contents SIMATIC RF300 System Manual, xx/2020, C79000-G8976-C345-08...
  • Page 5: Simatic Rf360R

    You can loop the PROFINET IO via the M12 round socket Note Configuration Manual SIMATIC RF360R You can find a detailed description of commissioning and configuration of the reader in the "SIMATIC RF360R (https://support.industry.siemens.com/cs/ww/en/ps/26319/man)" configuration manual. 1.1.2 Ordering data Table 1-1...
  • Page 6: Connecting The Reader To Functional Ground

    4. Screw the cable lug together with the M3 fastening screws with a torque of 1.2 Nm. NOTICE Low-impedance connection Ensure a low impedance connection between the reader module and the functional ground. When attaching the grounding cable, ensure it is not on a coated surface. SIMATIC RF300 System Manual, xx/2020, C79000-G8976-C345-08...
  • Page 7: Connecting Readers

    If you want to make the cable yourself, ensure that the conductor cross-section matches the system setup or the corresponding protection (1.5 mm When using cables that are not preassembled, you need the tool for the specific cable/connector, for example, an insulation stripper, screwdriver or Allen wrench. SIMATIC RF300 System Manual, xx/2020, C79000-G8976-C345-08...
  • Page 8: Pin Assignment Of The Interfaces

    The following tables show the pin assignment for the interfaces/connectors. Table 1-2 Pin assignment power supply; M12 socket (4-pin, L-coded) Assignment View of M12 socket, 4-pin +24 V (brown) Unassigned (white) Ground/shield (blue) Reset to Factory (black) SIMATIC RF300 System Manual, xx/2020, C79000-G8976-C345-08...
  • Page 9: Led Displays

    Operating mode "without presence": Transponder present and command cur‐ rently being executed There is an error. The number of flashes provides information about the current error. You can find more information on error messages in the section "AUTOHOTSPOT". SIMATIC RF300 System Manual, xx/2020, C79000-G8976-C345-08...
  • Page 10: Ensuring Reliable Data Exchange

    • LED test while the reader is starting up. • A connection is available. 1.1.7 Ensuring reliable data exchange The "center point" of the transponder must be situated within the transmission window. SIMATIC RF300 System Manual, xx/2020, C79000-G8976-C345-08...
  • Page 11: Metal-Free Area

    The RF360R can be flush-mounted in metal. Allow for a possible reduction in the field data. To avoid any influence on the field data, the distance "a" should be kept to. a ≥ 20 mm Figure 1-2 Metal-free area for RF360R SIMATIC RF300 System Manual, xx/2020, C79000-G8976-C345-08...
  • Page 12: Minimum Distance Between Several Rf360R Readers

    Minimum distance between several RF360R readers RF360R side-by-side D ≥ ≥ 350 mm (with 2 readers) ≥ 500 mm (with more than 2 readers) Figure 1-3 Minimum distance between several RF360R readers RF360R face-to-face D ≥ 500 mm SIMATIC RF300 System Manual, xx/2020, C79000-G8976-C345-08...
  • Page 13: Technical Specifications

    100 Mbps Connector 2x M12 interface, 4-pin, D-coded Max. cable length 100 m Cable type STP Cat 5 Autonegotation Autocrossing Switch function Yes, internal PROFINET RT Vendor ID 0x002A Device ID 0x0C09 Mechanical specifications SIMATIC RF300 System Manual, xx/2020, C79000-G8976-C345-08...
  • Page 14: Approvals

    EN 301489, CE, FCC, UL/CSA (IEC 61010) MTBF 65 years 1.1.11 Approvals FCC information Siemens SIMATIC RF360R (MLFB 6GT2801-5BA30); FCC ID NXW-RF360R This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: SIMATIC RF300 System Manual, xx/2020, C79000-G8976-C345-08...
  • Page 15 NOTE 1: These levels of transient overvoltage are typical for equipment supplied from the building wiring. • f) using a "NEC Class 2" power supply is required • g) the device is categorized as pollution degree 3/4 SIMATIC RF300 System Manual, xx/2020, C79000-G8976-C345-08...
  • Page 16: Dimension Drawing

    1.1 SIMATIC RF360R 1.1.12 Dimension drawing Figure 1-5 Dimensional drawing of RF360R Dimensions in mm SIMATIC RF300 System Manual, xx/2020, C79000-G8976-C345-08...