HART
communicator for
TZID-C/TZID-C200
positioner
42/18-75 EN
Rev. 02
Table of Contents
loading

Summary of Contents for ABB HART HHT 275

  • Page 1 ® HHT 275 HART communicator for TZID-C/TZID-C200 positioner Manual 42/18-75 EN Rev. 02 TZID-C: -/- Online 1 -> Serve/Watch Settings TZID-C: -/- TZID-C: -/- Diagnostics Online Online Simulation 1 -> -> Serve/Watch Serve/Watch Information Settings Settings TZID-C: -/- Diagnostics Diagnostics TZID-C: -/- Online Simulation...
  • Page 2: Table Of Contents

    General Table of contents General ..........................2 Connection .......................... 2 Operation ..........................3 Main menu ........................... 4 Serve/Watch" menu......................6 "Settings" menu ........................7 "Diagnostics" menu......................12 "Simulation" menu ......................13 "Information" menu ......................13 10 Troubles and errors ......................14 ®...
  • Page 3: Operation

    Operation Operation Function On/Off key Move cursor to next menu item Move cursor to previous menu item Select function/menu item Return to previous selection Hot key Function keys, function depending on menu (see list below): ABORT Abort current function BACK Return to current function Delete character right of cursor ENTER...
  • Page 4: Main Menu

    Main menu ® If the TZID-C/TZID-C200, with which you try to communicate via the HART communi- cator has already been set locally to the Conf mode, the following message will pop up: "Local configuration is active occurred reading ... value. Press OK." In this case it is not possible to configure the positioner via the communicator.
  • Page 5 Main menu Menu tree Setpoint Online Position Difference Tolerance band Serve/Watch Shut off value Temperature Lower current val Setpoint range Upper current val Operating mode General messages Messages Alarms Alarmmask Lower current val Setpoint range Upper current val Tolerance band Travel range min Travel range Travel range max...
  • Page 6: Serve/Watch" Menu

    "Serve/Watch" menu "Serve/Watch" menu IIn this menu you can call up several parameters for display in order to monitor the pro- cess. Some of them are shown directly in the menu line, others have to be called up by entering the item No. Pressing (EXIT) will return you to the "Serve/Watch"...
  • Page 7: Settings" Menu

    "Settings" menu Messages Enter the item No. to display the desired message(s). Pressing (HOME) will return you to the main menu. General messages Display general device messages. Press (OK) to acknowledge. Alarms Display the current alarm messages. If no alarms are present, the message "No alarms"...
  • Page 8 "Settings" menu (DEL) Deletes the entry. (ESC) or (ABORT) Exits from the value window without taking over the changes. The previous setting is restored instead. Confirms the entry and starts the data transmission procedure. 1 TZID-C parameter Setpoint range Lower current value Enter the low setpoint range limit.
  • Page 9 "Settings" menu 10 Alarm limits Alarm limit 1 Enter alarm limit 1 as a percentage of the stroke range. Alarm limit 2 Enter AL2 as a percentage of the stroke range. Alarm, S1 and S2 Select the alarm and switching outputs according to the following table: AlarmOn=active low OFF = alarm output HIGH active ON = alarm output LOW active...
  • Page 10 "Settings" menu Valve parameters Manual Valve range 1 Min valve range Enter the low valve range limit as a percentage of the lever range. 2 Max valve range Enter the high valve range limit as a percentage of the lever range. Digital setpoint 1 Setpoint mode This item is used to define the setpoint (analog or digital) to be used by the...
  • Page 11 "Settings" menu 6 Go pulse dn Edit the go pulse down. 7 Offset up Edit the up offset. 8 Offset down Edit the down offset. 9 ADC noise Edit the noise band. Auto configuration Auto conf modes With this menu item you can select the desired auto-configuration mode. Options: - Complete auto-configuration - Control parameters only - Valve range only...
  • Page 12: Diagnostics" Menu

    "Diagnostics" menu Dig pos feedback Alarm S1 and S2 Select the alarm and switching outputs for the module for "digital position feed- back": AlarmOn=active low OFF = alarm output HIGH active ON = alarm output LOW active S_1ON=active low OFF = switching point 1 HIGH active ON = switching point 1 LOW active S_2ON=active low OFF = switching point 2 HIGH active...
  • Page 13: Simulation" Menu

    "Simulation" menu "Simulation" menu Simulation Switches the simulation in the TZID-C/TZID-C200 on ("active") or off ("inactive"). Two minutes after the last user actions the TZID-C/TZID-C200 positioner returns to the local mode. Note that the values are not polled automatically. Switch the communicator off and on again to update the display.
  • Page 14: Troubles And Errors

    Troubles and Errors TZID-C Ident no. Display the TZID-C/TZID-C200 serial number. Hardware rev Display the TZID-C/TZID-C200 hardware revision Software rev Display the TZID-C/TZID-C200 software revision. Valve ID no Display the TZID-C/TZID-C200 manufacturing number. Sensor type Display the sensor type. PV Snsr s/n Display the sensor number.
  • Page 15 Subject to technical changes ABB Automation Products GmbH Printed in the Fed. Rep. of Germany Schillerstraße 72, D-32425 Minden 42/18-75 EN Rev. 02 Phone: +49(0) 5 71 83 0 - 0 Release 01.02...