Honeywell CIU 888 Sealing Manual

Honeywell CIU 888 Sealing Manual

Hide thumbs Also See for CIU 888:

Quick Links

Sealing Guide
Release R160
loading

Summary of Contents for Honeywell CIU 888

  • Page 1 Sealing Guide Release R160...
  • Page 3 CIU 888, and who may need to break the seal of the CIU 888 in order to change the configuration settings Other users who may need to break the seal of the CIU 888 in order  to change the configuration settings Part No.: 4417595_Rev10...
  • Page 4 Preface This page is intentionally left blank Sealing Guide Part No.: 4417595_Rev10 CIU 888...
  • Page 5 1.6 Sealing the CIU 888 ........
  • Page 6 Table of Contents This page is intentionally left blank Sealing Guide Part No.: 4417595_Rev10 CIU 888...
  • Page 7 6. Sealing the CIU 888, see section 1.6 1.1 Unlocking the configuration settings of the CIU 888 The first step in the procedure for sealing the CIU 888, is unlocking both the W&M relevant and the non-W&M relevant configuration settings of the CIU 888.
  • Page 8 1. Connect a PC/laptop with a standard web browser, i.e. Internet Explorer 9 or 10, to the Service port of the CIU 888 using a Cat. 5 Ethernet cable (patch or crossover). The Service port is located at the front of the CIU 888 (see FIGURE 1-3).
  • Page 9 Table of Contents 2. Launch the web browser. 3. Enter the IP address of the CIU 888 in the address bar of the web browser. The IP address is 192.1681.1. Next, press the Enter key. The CIU 888 Login window is displayed (see FIGURE 1-4).
  • Page 10 CIU 888 Web interface: Configuration window The Configuration windows displays the global settings and internal SI units that have been configured for the CIU 888, and indicates for each global setting whether it is W&M relevant or not. Furthermore, the Configuration window provides for each site element (tank, port, gauge) in the site tree an overview of the configuration settings.
  • Page 11 1.3 Sealing the Entis Pro system connected to the CIU 888 Once the W&M relevant configuration settings have been verified, the next step is to seal the Entis Pro system connected to the CIU 888. Sealing the Entis Pro system is required in order to proof that the software has not been changed.
  • Page 12 CIU 888 web interface provides option to calibrate/uncalibrate ambient temperature. If ambient temperature needs to be calibrated then use this option. 1. Login into CIU 888 web page using “ciuadmin” user account. 2. Select CONFIGURE tab. 3. On siteelement tree, select the gauge that is associated with the ambient temperature scan.
  • Page 13 “Uncalibrate Ambient Temperature” and click Update. 1.5 Locking the W&M relevant configuration settings of the CIU 888 Once the required entities of all tanks associated with the CIU 888 have been calibrated, the next step is locking the W&M relevant configuration settings of the CIU 888: Perform the following steps to lock the W&M relevant configuration...
  • Page 14 Table of Contents 1. Open the cover of the W&M lock key switch. The W&M lock key switch is located at the front of the CIU 888 (see FIGURE 1-7). FIGURE 1-7 CIU 888: W&M lock key switch 2. Insert the key into the W&M lock key switch and turn it counter- clockwise.
  • Page 15 (see FIGURE 1-9). FIGURE 1-9 CIU 888: Cover of W&M lock key switch 2. Seal the cover of the CIU 888 in one of the following ways: Attach a permanent self-adhesive seal/sticker to the cover of the ...
  • Page 16 W&M certified option. FIGURE 1-10 CIU 888: Example of location for seal/sticker Use a sealing wire to attach the cover of the CIU 888 to the fixing  point at the back of the CIU 888 (see FIGURE 1-11).
  • Page 17: Appendix A List Of Abbreviations

    APPENDIX A LIST OF ABBREVIATIONS Abbreviation Description Communication Interface Unit Internet Protocol Netherlands Measurement Institute (Nederlands Meetinstituut) Personal Computer SI Units International System of Units (from French: Système International d'Unités) W&M Weights and Measures Part No.: 4417595_Rev10 Sealing Guide CIU 888 A - 1...
  • Page 18 This page is intentionally left blank Sealing Guide Part No.: 4417595_Rev10 A - 2 CIU 888...
  • Page 19 +1 800 423 9883 or +1 215 641 3610 E-mail: [email protected] Copyright © 2020 - Honeywell All rights reserved. No part of this manual may be reproduced in any form, by print, photoprint, microfilm or any other means without the written permission from Honeywell.
  • Page 20 For More Information To learn more about Honeywell Enraf’s solutions, contact your Honeywell Enraf account manager or visit www.honeywellenraf.com. Americas Asia Pacific Honeywell Enraf Americas, Inc. Honeywell Pte Ltd. 1250 West Sam Houston Pkwy S. 17 Changi Business Park Central 1...