Summary of Contents for Honeywell ADPRO iFT Series

  • Page 1   ADPRO iFT Series   Quick Setup Guide October 2019 Doc. 27929_07 Software version XO 4.5...
  • Page 3 ADPRO ADPRO iFT Series Quick Setup Guide Disclaimer The contents of this document are provided on an "as is" basis. No representation or warranty (either express or implied) is made as to the completeness,  accuracy or reliability of the contents of this document. The manufacturer reserves the right to change designs or specifications without obligation and without  further notice. Except as otherwise provided, all warranties, express or implied, including without limitation any implied warranties of merchantability and  fitness for a particular purpose are expressly excluded. Intellectual Property and Copyright This document includes registered and unregistered trademarks. All trademarks displayed are the trademarks of their respective owners. Your use of this  document does not constitute or create a license or any other right to use the name and/or trademark and/or label. This document is subject to copyright owned  by Honeywell. You agree not to copy, communicate to the public, adapt, distribute, transfer, sell, modify, or publish any contents of this document without the  express prior written consent of Honeywell. Trade Name Statement ADPRO, FastTrace, iFT, iFT-E, iFT Gateway, IntrusionTrace, LoiterTrace, XO, iTrace, iCommand, iCommission, iPIR, and FMST are trademarks and/or  registered trademarks of Honeywell and/or its subsidiaries in the United States and/or other countries. Other brand names mentioned herein are for  identification purposes only and may be trademarks of their respective holder(s). Your use of this document does not constitute or create a licence or any other  right to use the name and/or trademark and/or label. General Warning This product must only be installed, configured and used strictly in accordance with the General Terms and Conditions, User Manual and product documents  available from Honeywell. All proper health and safety precautions must be taken during the installation, commissioning, and maintenance of the product. The  system should not be connected to a power source until all the components have been installed. Proper safety precautions must be taken during tests and  maintenance of the products when these are still connected to the power source. Failure to do so or tampering with the electronics inside the products can  result in an electric shock causing injury or death and may cause equipment damage. Honeywell is not responsible and cannot be held accountable for any  liability that may arise due to improper use of the equipment and/or failure to take proper precautions. Only persons trained through an Honeywell accredited  training course can install, test and maintain the system. Liability You agree to install, configure, and use the products strictly in accordance with the User Manual and product documents available from Honeywell. Honeywell is not liable to you or any other person for incidental, indirect, or consequential loss, expense or damages of any kind including without limitation,  loss of business, loss of profits, or loss of data arising out of your use of the products. Without limiting this general disclaimer the following specific warnings ...
  • Page 4 ADPRO iFT Series Quick Setup Guide ADPRO Contact Us UK and Europe +44 1442 242 330 D-A-CH +49 431 23284 1 The Americas +1 781 740 2223 Middle East  +962 6 588 5622 Asia +86 21 5240 0077 Australia and New Zealand +61 3 9936 7000 www.security.honeywell.com Environmental Information The crossed-out wheeled bin means that within the European Union the product must be taken to separate collection at the product end  of life. This applies to the device but also to any accessories marked with this symbol. Do not dispose of these products as unsorted  municipal waste. If you need more information on the collection, reuse, and recycling systems please contact your local waste administration. You can  also contact us for more information on the environmental specifications of our products. 27929_07...
  • Page 5: Table Of Contents

    ADPRO ADPRO iFT Series Quick Setup Guide Contents Packing List Power Requirements Safety Instructions Technical Documents Installing the XO Client Software on Your PC System Requirements for the Client PC 5.1.1 Hardware 5.1.2 Software Installing the XO Client Software 5.2.1 Internet Explorer Settings 5.2.2 Changing the PC’s IP Address 5.2.3 Installation Launching the XO Client...
  • Page 6: Power Requirements

    ADPRO iFT Series Quick Setup Guide ADPRO Packing List After unpacking, check for any signs of damage. Report any damage to your supplier immediately. Also check  whether all items are present: ®   ADPRO  iFT Series device   Power cord   CD with client software and manuals   Quick Setup Guide   19" mounting brackets, black   Set of resistors (for built-in Main I/O card)   Set of 4 rubber feet to use the device as a desktop unit. The products are provided with a plug according to the National Heavy Current Regulations of the country of  shipment. Installation shall be done according to National Regulations. Note Wherever iFT Series device or XO device is mentioned in this document, it refers to all models of  the iFT Series unless specifically mentioned otherwise. Power Requirements The XO device is designed for 100–240 V~, 50/60 Hz operation. XO devices comply with EMF emission and ...
  • Page 7: Installing The Xo Client Software On Your Pc

    ADPRO ADPRO iFT Series Quick Setup Guide Installing the XO Client Software on Your PC System Requirements for the Client PC 5.1.1 Hardware The following are the recommended hardware requirements to run the XO client on a PC:   Intel Core i5 processor with 8GB RAM   Graphics card with DirectX 12 support and the capability for using YUV surfaces and hardware stretching.  Intel® HD Graphics 630 is recommended.                   The rendering switches to the GDI mode when the graphics card does not have this support. Rendering in GDI  mode is not recommended because of high CPU utilization.  The embedded client application is now by default a 64-bit application, and the customers who require a 32-bit ...
  • Page 8: Internet Explorer Settings

    ADPRO iFT Series Quick Setup Guide ADPRO Note Webserver is disabled by default starting with ADPROXO 4.5. It can only be reenabled by a  technician on a system in which an admin user has enabled the technical grant. To install the client  software using the XO device’s web page, the webserver must be enabled by the technician which is  a security risk. You can get the client software from the release DVD or from the support site  (www.xtralissecurity.com). 5.2.1 Internet Explorer Settings Note The preferred browser for installing the XO client software is Internet Explorer. If you cannot use  Internet Explorer, try any other internet browser. In this case, you have to install the MeadCo Neptune  plugin. You can download the plugin from www.meadco.com/Neptune/Download. When installing the XO client software via the XO device's web page, you need to add the XO device’s IP  address to your Trusted sites in Internet Explorer. The XO device’s default IP address is 10.0.0.10 with subnet  mask 255.255.255.0. Proceed as follows: 1.  In Internet Explorer, choose Tools > Internet options. 2.  Click the Security tab. 3.  In the Select a zone… box, click Trusted sites, and then click Sites. 4. ...
  • Page 9: Installation

    ADPRO ADPRO iFT Series Quick Setup Guide 9.  Click OK to close the window. Note You can check the XO device information by running the following commands when you are  connected to the device with a monitor and keyboard. ALT + F1 To display the IP details ALT + F7 To display the cameras in matrix layout 5.2.3 Installation Note Webserver is disabled by default starting with ADPRO XO 4.5. It can only be reenabled by a  technician on a system in which an admin user has enabled the technical grant. To install the client  software using the XO device’s web page, the webserver must be enabled by the technician which is  a security risk. You can get the client software from the release DVD or from the support site  (www.xtralissecurity.com). To install the XO client software via the XO device's web page, proceed as follows: 1.  Connect your PC to the XO device’s eth0 port with an RJ45 network cross cable or via the network  switch/router on the eth0 port.  2.  Open Internet Explorer and enter the XO device’s IP address, followed by /setup.php For example:http://10.0.0.10/setup.php 3.  Click setup.exe. 27929_07...
  • Page 10 ADPRO iFT Series Quick Setup Guide ADPRO 4.  Click Run to start the installation. Note Your virus scanner may block this download. Disable your virus scanner temporarily if this  occurs. Remember to switch it back on after installation. 5.  The following warning message may appear: Do you want to allow the following program from an unknown publisher to make changes to this computer? In this case, click Yes to start the installation.  6.  Click Yes in the following message. This message is displayed as changing the default password for XO  device from first login is made mandatory since XO 04.05.005.  7.  Click OK to uninstall the previous XO client.
  • Page 11 ADPRO ADPRO iFT Series Quick Setup Guide 10.  Click I Agree to agree with the terms of the license agreement. 11.  Accept or modify the installation folder. Click Next. 12.  Accept or modify the default work folder (= the folder for storing snapshots and downloaded recordings).  Also select your preferred language. Click Install, and wait for the following screen to appear: 27929_07...
  • Page 12: Launching The Xo Client

    ADPRO iFT Series Quick Setup Guide ADPRO 13.  When the installation is completed, click Close to exit the installation Wizard. The new client version is now  installed. Launching the XO Client To launch the XO client, proceed as follows: 1.  On the desktop, double-click the XO client icon  If the icon is not available, you can press Start and choose All Programs > ADPRO XO > AdproXO. The  following window appears: The Login window displays all your XO devices so that you can quickly connect to them. 2.  To set up how the client launches, click Settings. 27929_07...
  • Page 13: Adding An Xo Device To The Xo Client

    ADPRO ADPRO iFT Series Quick Setup Guide 3.  Provide the following information: Item Description English, Select the desired language for the application. Français… GUI style Select a style to change the appearance of the application. The changes will only take  effect after you restart the client software. Path If required, change the default work folder (= the folder for storing snapshots and  downloaded recordings). Use hardware Select this option if you want to use hardware decoding on your client PC. Hardware  acceleration if decoding may enhance the rendering performance. available Save live view Set this option to Yes if you want to show the last used camera matrix in the live view.  If you set it to No, the live view window is empty when you start the client, and you  have to select the cameras for the live view matrix each time you start the client. Auto restart Set this option to Yes if you want the login window to reappear when you close the  client software. This allows you to quickly connect to another XO device.
  • Page 14 ADPRO iFT Series Quick Setup Guide ADPRO 3.  Click Add. The following window appears: 4.  Provide the following information: Item Description Name Type a meaningful name for the XO device. IP Address Type the IP address or DNS hostname of the XO device (default IP address is  10.0.0.10). RTSP Port Type the RTSP port number (default is 554) and the control port number (default  Control Port is 2000). Connection Select the TCP or UDP protocol. UDP is recommended, but TCP may be required if  Type the connection goes through a router that blocks the UDP packets. Username Enter the user ID/username and password of an existing user to log on to the XO  Password device. The default user ID is 0. The XO device has 666777 as the initial password  which is changed at the first login. Note Entering a password is optional. If you leave the Password box blank,  you have to fill in the password manually each time you connect to the  device.
  • Page 15: Connecting To An Xo Device

    ADPRO ADPRO iFT Series Quick Setup Guide 6.  Repeat for any other XO devices that you want to add. Connecting to an XO Device To connect to an XO device, proceed as follows: 1.  Launch the XO client. The list of XO devices appears. The system automatically selects the last used XO  device. 2.  Click the desired XO device in the list, and then click Connect. Alternatively, double-click the desired XO device in the list. The Live Video screen appears: 27929_07...
  • Page 16 ADPRO iFT Series Quick Setup Guide ADPRO Note If you did not specify a password for connecting to the device, the following screen appears: Enter the password and click Login.                                                       27929_07...
  • Page 17 ADPRO ADPRO iFT Series Quick Setup Guide                                     27929_07...
  • Page 18 ADPRO iFT Series Quick Setup Guide ADPRO 27929_07...
  • Page 20 UK and Europe +44 1442 242 330 D-A-CH +49 431 23284 1 The Americas +1 781 740 2223 Middle East  +962 6 588 5622 Asia +86 21 5240 0077 Australia and New Zealand +61 3 9936 7000 A Disclaimer about this document, statements about Intellectual Property, Copyrights, and Liability, as well as a General Warning are available in an earlier section of this document.

Table of Contents