Torque Monitoring - Bosch Servodyn-D Manual

With canrho interface, commissioning with dss
Table of Contents
Initial commissioning
4–10
4.2.9

Torque monitoring

Every drive is equipped with 2 monitoring features each of which can be con-
figured independently.
Every monitoring feature compares the current torque value with its specific
limit values and stores the result of the comparison in a separate parameter.
Since both parameters have been implemented as real-time bits (signal sta-
tus bits), one of them can be assigned to the hardware output OUT1 of the
drive and evaluated, e.g. by the PLC.
S-0-0334
Message
|Md| y Md
limit
S-0-0333
Message
|Md| y Md
x
If one of the monitoring features responds (= contents of S-0-0333 or
S-0-0334 becomes HIGH), the drive internally responds by setting certain
bits in parameter S-0-0013 (diagnostics class 3).
.
Further reactions (such as reduction of torque or speed, retract move-
ments, EMERGENCY-STOP) have to be initiated externally by the PLC!
L
Adjust the limit values for torque monitoring to your requirements.
L
Assign parameters S-0-0333 or S-0-0334 to hardware output OUT1 of the
drive in order to provide for evaluation (cf. page 4–8).
L
Execute the "Save main memory" command.
Md
limit
S-0-0092
y
|Md|
S-0-0084
|Md|
y
S-0-0126
Md
x
1070 066 037-101 (00.02) GB
Torque limit
values:
(bipolar)
torque actual
value
torque threshold