Load Main Memory; Resetting Errors (Class 1) - Bosch Servodyn-D Manual

With canrho interface, commissioning with dss
Table of Contents
DSS user interface
3–10
3.5.3

Load main memory

3.5.4

Resetting errors (class 1)

This command loads all data stored in the FEPROM to the drive RAM.
When the inverter has been switched on, or if the "Reset" button at the in-
verter has been depressed, the drive automatically copies all data contained
in the FEPROM to the RAM.
CAUTION
The main memory of the drive is overwritten!
All data in the RAM will be replaced with the parameters contained
in the FEPROM by the "Load main memory" command. This process
cannot be reversed.
If you are not sure whether you still need the old RAM data, please
contact your systems administrator before executing this command.
L
Change the drive to phase 0, 1, 2 or 3.
L
Select the menu sequence:
CONTROL " MAIN MEMORY " LOAD
If errors of diagnostics class 1 have occurred, the drive will be interlocked
(optimum shut-down with subsequent torque removal).
To enable the drive again, proceed as follows:
L
Open the logbook for class 1 errors (cf. section 6.1) which contains a list of
codes of the pending errors.
L
Locate the cause of the error and eliminate all errors.
L
Initiate the "Reset class 1 error" command:
D menu sequence
CONTROL " RESET " RESET CLASS 1 ERROR, or
D click on
in the icon bar.