Siemens LOGO! 8 Manual

Siemens LOGO! 8 Manual

House control with master-slave communication
Hide thumbs Also See for LOGO! 8:
House Control with
Master-Slave
Communication
LOGO! 8
Set 9
https://support.industry.siemens.com/cs/ww/en/view/64143308
Frei verwendbar
Siemens
Industry
Online
Support
Table of Contents
loading

Summary of Contents for Siemens LOGO! 8

  • Page 1 House Control with Master-Slave Communication LOGO! 8 Siemens Set 9 Industry Online https://support.industry.siemens.com/cs/ww/en/view/64143308 Support Frei verwendbar...
  • Page 2: Legal Information

    The foregoing provisions do not imply any change in the burden of proof to your detriment. You shall indemnify Siemens against existing or future claims of third parties in this connection except where Siemens is mandatorily liable.
  • Page 3: Table Of Contents

    PC ....................20 3.3.5 IP addresses and subnet masks ............21 Downloading a program into LOGO! 8 ..........21 Setting web server access ............... 23 User defined Webserver (LOGO! V8.2) ..........25 Adjust the runtime of the blinds in the LOGO! program ..... 27 Operating the Application Example .............
  • Page 4: Task

    1 Task Task Introduction In residential house, the following functions shall be controlled manually or automatically: • Blinds and Roof hatch (up/down) • Interior and exterior lighting (on/off) • Heater • Garden watering Figure 1-1 Blinds Blinds Roof hatch Interior light (up/down) (up/down) (up/down)
  • Page 5: Solution

    The figure below shows an overview of the important components of the solution: Figure 2-1 PROFINET IE In the automation solution, one LOGO! 8 (1) is used as master and one as slave. Both LOGO! modules communicate via a Compact Switch module (2). Additional extension modules were deployed for each LOGO! module.
  • Page 6 This enables to control the blinds, lights and roof hatch and to display their current status with a tablet (9), smartphone or PC using the integrated web server of the LOGO! 8. A LOGO! power supply (10) with 24V is used in the automation solution.
  • Page 7: Hardware And Software Components

    2 Solution Hardware and software components 2.2.1 Components used The application example was created with the following components: Hardware components Table 2-1 Component Article number Note LOGO! 12/24RCE 6ED1052-1MD08-0BA0 LOGO! CSM12/24 6GK7177-1MA20-0AA0 If you would like to integrate additional Ethernet inter- COMPACT SWITCH faces in the network (e.g.
  • Page 8: House Functions

    2 Solution Software components Table 2-2 Component Article number Note LOGO! Soft Comfort V8 6ED1058-0BA08-0YA1 Update V8.2 (Download) LOGO! Web Editor (Download) Example files and projects The following list includes all files and projects that are used in this example. Table 2-3 Component Note...
  • Page 9 CAUTION This version of Set 9 (different than sets 9, 10 and 11 based on LOGO! 7) is based on LOGO! 8 and requires the use of modern blind drives with integrated end position switch. If this requirement is not observed, the blind drives can be damaged.
  • Page 10 2 Solution Note More information on how to modify parameters with the LOGO! display or LOGO! TDE is available in the LOGO! manual in Chapter "Configuring LOGO!". Table 2-5 Function Function block Block name in the program Moving blinds up/down on weekends Weekly timer weekend Moving blinds up/down Monday to...
  • Page 11: Roof Hatch

    PC with the F1 function key over the integrated webserver of LOGO! 8. In automatic mode, the roof hatch is controlled with the PT100 (see...
  • Page 12: Heating

    2 Solution 2.3.3 Heating Inputs and outputs Table 2-8 Hardware LOGO! module Program inputs/outputs PT100 temperature sensor Master RTD A1 PT1000 temperature sensor Master RTD A2 Heating room 1 on/off Master DM8 Q1 Heating room 2 on/off Master DM8 Q2 Function description With the LOGO! display and LOGO! TDE it is possible to set a setpoint value for each room.
  • Page 13: Garden Watering

    2 Solution 2.3.4 Garden watering Function description The LOGO! TDE or the LOGO! display can be used to predefine manual or automatic control of the garden watering. In manual mode, the garden watering can be controlled with the cursor keys over the LOGO! controller and the LOGO! TDE.
  • Page 14 LOGO! controller and the LOGO! TDE. In addition, the lights can be controlled with a tablet, smartphone or PC with the F-keys over the integrated webserver of LOGO! 8. The panic mode is activated when one of the light buttons is pressed for at least 3 seconds.
  • Page 15: Reading Inputs From A Slave Logo! And Controlling Outputs Of A Slave Logo

    2 Solution Reading inputs from a slave LOGO! and controlling outputs of a slave LOGO! When the master/slave mode is set, you can read inputs from a slave LOGO! and control outputs of a slave LOGO!. The table below describes the LOGO! program settings for this: Table 2-13 Action/response LOGO! Soft Comfort V8...
  • Page 16 2 Solution Action/response LOGO! Soft Comfort V8 If you want to use the input of the slave LOGO! in the program, select a digital "Network input” from the "Instructions tree” and add it to your switching program. Then double click on the digital "Network input”...
  • Page 17 2 Solution Action/response LOGO! Soft Comfort V8 Then you need to define which slave LOGO! input you want to read. The digital network input is displayed in green, which means that LOGO!-Soft Comfort V8 has automatically created an Ethernet connection and a data transfer mechanism between the master and the slave LOGO!.
  • Page 18: Installation And Commissioning

    Installing the hardware 3.1.1 LOGO! 8 and TDE Please note the respective setup guidelines for LOGO! 8 and LOGO! TDE. Further information is available in the LOGO! manual in chapter "LOGO! installation and wiring”.
  • Page 19: Commissioning

    First, configure the master LOGO!. Go to the "Network” item via the LOGO! display using the cursor keys C1▲ or C2▼ on the LOGO! 8 and press OK. Select "IP address”. Press the OK button of the LOGO! controller and use the cursor keys C1▲, C2▼, C3 ◄...
  • Page 20: Assigning An Ip Address To Logo! Tde

    3.3.4 Please ensure that the IP address of the network connection of your PC (or USB Ethernet adapter) used for connecting to LOGO! 8 is located in the same subnet as the master and slave LOGO! and LOGO! TDE. An instruction on how to change the IP address of a network card is available, for example, on the internet in the Microsoft Knowledge Base under "Change TCP/IP...
  • Page 21: Ip Addresses And Subnet Masks

    Together with this application example a completed LOGO! program for LOGO! 8 is offered for download. The table below contains a description on how to load the completed LOGO! program into LOGO! 8. Start LOGO! Soft Comfort V8 and make the following settings:...
  • Page 22 3 Installation and Commissioning Action/response LOGO! Soft Comfort V8 Click the "Download” button. Select the "Interface” for your connection to LOGO!. Enter the IP address of your LOGO!. Click "Test” in order to check whether the connection has been established successfully.
  • Page 23: Setting Web Server Access

    3 Installation and Commissioning Setting web server access To be able to operate the application example using the integrated LOGO! web server, the web server must first be enabled using the LOGO! Soft Comfort V8 menu. Start LOGO! Soft Comfort V8 and make the following settings: Table 3-4 Action/response LOGO! Soft Comfort V8...
  • Page 24 3 Installation and Commissioning Action/response LOGO! Soft Comfort V8 Navigate to the "Web server access” item and tick the box for "Allow Web server access”. Acknowledge the warning message with "Yes”. Tick "Enable password protection for Web server access” and enter a password.
  • Page 25: User Defined Webserver (Logo! V8.2)

    Tablet PCs (optimized resolution) All compatible web browsers User defined Webserver (LOGO! V8.2) Since version 8.2, LOGO! 8 offers a user-defined web server. The web project is created with the LOGO! web editor (LWE) and loaded onto a Micro-SD card.
  • Page 26 3 Installation and Commissioning Figure 3-1 displays the interface of the web editor. In addition to static picture elements, the Web Editor also offers digital buttons and analog operating elements that are linked to the switching program in the LOGO! basic device. In the figure, for example, the flag [M51] from the LOGO! Soft Comfort circuit program (1) is linked to the button in the Web editor (2).
  • Page 27: Adjust The Runtime Of The Blinds In The Logo! Program

    3 Installation and Commissioning Adjust the runtime of the blinds in the LOGO! program In the LOGO! program a blind runtime of 40 seconds until the end stop is defined. Check the exact runtime until end stop of the blinds you use. If the runtime is a different value than 40 seconds we recommend the settings of following parameters for an optimized control of the blinds and for display: Table 3-5...
  • Page 28 3 Installation and Commissioning Action/response KTP700 display Go to function block B161 and open the block properties with a double-click. Double-click on the bar graph to get to its parameters. Set the maximum value to the value you noted down in item 5. Save the settings with "OK”.
  • Page 29: Operating The Application Example

    LOGO! controller and the LOGO! TDE with the cursor keys • remote-controlled with a tablet, smartphone or PC with the F-keys over the integrated webserver of LOGO! 8 Risk of property damage or personal injury. When controlling the functions of the application example over the cursor keys or over the F-keys, be sure that you don’t control in mixed operation on the HW as...
  • Page 30: Menu Overview For The Control Of The House Functions With The Logo! Tde Or Logo! Display

    4 Operating the Application Example Menu overview for the control of the house functions with the LOGO! TDE or LOGO! display Table 4-1 Description LOGO! display and LOGO! TDE Main menu Blinds: Change mode Blinds: Maintenance mode Blinds: Central control Frei verwendbar House Control with Master-Slave - LOGO! Set 9 Entry ID: 64143308, V2.2,...
  • Page 31 4 Operating the Application Example Description LOGO! display and LOGO! TDE Lights: Central control Lights: Change mode Hatch roof: Change mode Hatch roof: Auto mode Watering Frei verwendbar House Control with Master-Slave - LOGO! Set 9 Entry ID: 64143308, V2.2, 09/2018...
  • Page 32 4 Operating the Application Example Description LOGO! display and LOGO! TDE Room 1: Room temperature Room 2: Room temperature Note When the panic function is activated, a warning message is displayed on the LOGO! display and on the LOGO! TDE that all lights are on. At the same time the LOGO! display lights up orange.
  • Page 33: Operating Example For Use Of The Logo! Display And Logo! Tde: Central Blind Control

    4 Operating the Application Example 4.2.1 Operating example for use of the LOGO! display and LOGO! TDE: Central blind control Table 4-2 Action/response LOGO! display and LOGO! TDE Use the cursor keys to go to the blind control menu. Press ESC+ C1▲. →...
  • Page 34: Operation Using The Web Server (Menu Overview)

    4 Operating the Application Example Action/response LOGO! display and LOGO! TDE Now, press one of the light buttons in the house for more than 3 seconds again. → The panic function has now been deactivated. Acknowledge the warning message with "OK” on the LOGO! or with "ENTER”...
  • Page 35: Operating Example For Light Control Via The Web Server

    4 Operating the Application Example 4.4.1 Operating example for light control via the web server Table 4-5 Action Web server screen (tablet, smartphone or PC) Open your internet browser (tablet, smartphone or PC) and carry out the following steps: Enter the IP address of your master LOGO! (here: 192.168.1.10).
  • Page 36: Bedienung Über Den Benutzerdefinierten Webserver

    4 Operating the Application Example Bedienung über den benutzerdefinierten Webserver Open your internet browser with the option "to customized site". Figure 4-1 points to the configured operating elements for the user-defined web server. In the web browser, click using the mouse, or on a touch screen, tap on the button with the function in Table 4-6.
  • Page 37: Appendix

    Industry Online Support Do you have any questions or need assistance? Siemens Industry Online Support offers round the clock access to our entire service and support know-how and portfolio. The Industry Online Support is the central address for information about our products, solutions and services.
  • Page 38: Bibliographic References

    Layout modified and security note amended V2.0 01/2015 Changes in LOGO! 8 V2.1 04/2016 Complete revision of software and documentation V2.2 09/2018 Changes in LOGO! 8 (user defined webserver) Frei verwendbar House Control with Master-Slave - LOGO! Set 9 Entry ID: 64143308, V2.2, 09/2018...

Table of Contents