Page 1
You are required to inspect your respirator prior to putting it into fi eld service. Please refer to the inspection procedures in this manual. Failure to comply with this warning may lead to illness, personal injury, or death. Honeywell International Inc. 900 Douglas Pike Smithfi eld, RI 02917...
Honeywell Titan SCBA, 20132 NOTE This section must be read in conjunction with the NIOSH approval label in this user’s manual. Failure to observe these cautions and limitations voids NIOSH approval. CAUTIONS AND LIMITATIONS D - Air line respirators can be used only when the respirators are supplied with respirable air meeting the requirements of CGA G-7.1 Grade D or higher.
Page 4
WARRANTY AND LIMITATION Of LIABILITY LIMITED WARRANTY: Honeywell warrants this product to be free from defects in materials and workmanship for 12 years from the date of purchase, with the exception of the compressed air cylinder—the standard cylinder is warranted for 15 years; the extended life cylinder is warranted for 30 years—and the fi rst stage pressure reducer, which is warranted for the life...
Honeywell Titan SCBA, 20132 TABLE Of CONTENTS CAUTIONS AND LIMITATIONS .........................i WARRANTY AND LIMITATION OF LIABILITY ..................ii I. INTRODUCTION ............................1 II. SAFETY PRECAUTIONS ........................1 III. PARTS LIST ............................3 IV. DESCRIPTION .............................6 A. Backpack and Cylinder .........................6 B. First Stage Pressure Reducer .......................6 C.
Page 6
Honeywell Titan SCBA, 20132 This page intentionally left blank...
CBRN agent levels. Although illness, or death if not carefully followed. the Titan SCBA will prevent penetration and permeation of specifi c concentrations of CAUTION CBRN agents, there could be environments...
Page 8
Honeywell Titan SCBA, 20132 WARNING—Continued WARNING—Continued negative facepiece pressures include, but be absorbed directly through the skin, while are not limited to: 1) the SCBA is improperly others may irritate exposed areas. Always worn, 2) the SCBA is not used in accordance...
BLACK, LARGE BLACK NOSE CUP, HEADNET possibility of agent permeation. 282050 FACEPIECE—TWENTY/20+, CBRN, MEDIUM, • Prior to using the Titan SCBA for the BLACK, SMALL BLACK NOSE CUP, HEADNET fi rst time, you must perform fi t testing as 282026 FACEPIECE—TWENTY/20+, CBRN, MEDIUM,...
Page 10
Honeywell Titan SCBA, 20132 Part No. Description Part No. Description 282043T FACEPIECE—TWENTY/20+, CBRN, LARGE, 930189 INTEGRATED BATTERY PACK, TITAN BLACK, SMALL BLACK NOSE CUP, W/TEMPLE 930186 BATTERY PACK HUD CONNECTOR, 2216 PSIG, INSERTS, SILICONE HEADSTRAP 282032T FACEPIECE—TWENTY/20+, CBRN, LARGE, BLACK, MEDIUM BLACK NOSE CUP, W/TEMPLE...
• Pressure reduction components. • Primary low air alarm activation and adjustment The Titan SCBA meets all requirements of the NFPA 1981 mechanisms. Standard, 2013 Edition, Open-Circuit Self-Contained • Intermediate pressure connections to the second Breathing Apparatus for Emergency Services.
(when look- NOTE ing at the cylinder with the valve pointing down) of the The Titan SCBA comes equipped with a Heads- backpack, using a coin, a large, fl at blade screwdriver, Up Display (HUD).
2. The RIC UAC is located adjacent to the CGA hand- WARNING —Continued wheel of the Titan SCBA, on the lower left side of the backpack (when looking at the cylinder with the valve • Turn off the free fl owing regulator by pointing down).
(6) hours after initial exposure to chemical warfare agents. • Prior to using the Titan SCBA for the fi rst time, you must perform fi t testing as described below. • Do not wear this respirator if a satisfactory fi...
Page 16
Honeywell Titan SCBA, 20132 piece should remain lightly collapsed until you exhale d. Center the facepiece and fl atten the headnet or until you take your palm from the opening. with a wiping motion toward the back of your head. See Figure 5.
Page 17
P100 fi lters with the palms of your hands, the operation manual. If the Titan SCBA a thin sheet of rubber or plastic, or a rubber glove. approval paper insert label is not present, b.
Honeywell Titan SCBA, 20132 b. Coat Style B. Donning the Backpack i. Insert your arm through one of the shoulder WARNING straps and swing the SCBA onto your back. Wear gloves when handling SCBAs that have been stored in extreme temperatures. Failure...
Honeywell Titan SCBA, 20132 C. Donning the facepiece vii. Perform a leak check as described in section VI, E, page 14. 10. Tighten the AIR KLIC (the adapter into which the second stage regulator is inserted) in the facepiece by NOTE turning it clockwise.
Honeywell Titan SCBA, 20132 1. Place the palm of your hand over the AIR KLIC as shown in Figure 19. Figure 17. Flatten the Headnet vi. Perform a leak check as described in section VI, E, page 14. Figure 19. Leak Check NOTE 2.
CGA handwheel, and is capable of accommodat- ing a 60-minute high pressure cylinder. Although it is possible to add air to a Honeywell SCBA via the RIC UAC system while the SCBA is being worn, Honey- Figure 21. Insert the Regulator...
fi ll process. • Never use the Honeywell RIC UAC to fi ll an 8. Close the cylinder valve on the fi ll system and vent SCBA air cylinder while the SCBA is being the air from the fi ll hose.
DO NOT allow moisture or ice to enter the d. Have the SCBA inspected and/or repaired by a regulator system. Moisture or ice entering Honeywell-certifi ed repair technician before reuse. the regulator system may cause the SCBA 5. PROBLEM: Second stage regulator accidentally to freeze up, restricting or stopping air fl...
Honeywell Titan SCBA, 20132 a. When replacing a cylinder of the same diameter tank band, tank band latches, cylinder valve, or back- or smaller diameter: pack. i. Flip the cam-over buckle on the right side up 2. The SCBA mounting position should prevent any...
Honeywell Titan SCBA, 20132 WARNING —Continued for dents, gouges, bulges, and evidence of exposure to open fl ame or heat sources which to high temperature such as darkened or blistered may heat the cylinder to 180°F. Cylinders paint, charred decals, melted or distored gauge lens, damaged by fi...
Air cylinders should be recharged as soon as is practi- • Silicone and rubber parts of the facepiece may cal after use. Cylinders should not be stored partially be cleaned between washing with Honeywell charged, for two reasons: Mask Wipes, P/N B140096.
D. Inspection (see Inspection Table, page 27) the regulator outlet. Honeywell recommends that the Titan SCBA be fully 1. Make a cleaning solution of warm water and a mild inspected upon initial receipt and on a regular schedule detergent.
Honeywell Titan SCBA, 20132 Honeywell also recommends a full fl ow test be per- WARNING—Continued formed per NFPA 1852, Standard on Selection, Care, maintained at -65°F (-53.9°C) or lower, or and Maintenance of Open-Circuit Self-Contained less than 24.0 ppm by volume. Air exceeding...
Have the facepiece inspected and/or repaired c. If ice is present, it may be melted by placing the by a Honeywell-certifi ed repair technician before regulator inside outerwear near the body to warm. reuse. d. Again, visually inspect the regulator for ice, then g.
Honeywell Titan SCBA, 20132 k. If the AIR KLIC buttons are frozen and the regulator with a gloved hand, or pass warm air over it. cannot be removed from the regulator holder, do not c. Heads-Up Display force the buttons. Unbuckle the waist belt, and place...
PosiChek3 with Honeywell-specifi c software. Mainte- the performance of the SCBA accessories. nance and repair, unless otherwise specifi ed in this manual, must be performed by a Honeywell-certifi ed a. Air line hoses can become stiff. technician. SCBAs subjected to daily or severe service, b.
LIMITATION Of LIABILITY: No other oral warranties, rep- Smithfi eld, RI 02917 resentations, or guarantees of any kind have been made by 1-800-873-5242 Honeywell, its distributors, or the agents of either of them, [email protected] that in any way alter the terms of this warranty. EXCEPT www.Honeywellsafety.com...
Honeywell Titan SCBA, 20132 X. INSPECTION TABLE If any of the listed defects are found, have the SCBA repaired before use. COMPONENT LOOK fOR 1. Nicks, scratches, or abrasions which could impair visibility. FACEPIECE LENS 2. Deep gouges or cracks which could reduce impact resistance.
7. Fit the facepiece over your face and cycle the exhalation valve by blocking the AIR KLIC opening with your palm and exhaling several times. 8. Perform a leak check as described in OPERATION INSTRUCTIONS, or conduct a facepiece leak test on the Honeywell Analytics PosiChek3 with Honeywell-specific software installed. NOSE CUP Replace the nose cup on the nozzle, aligning the slot on the nose cup with the tab on top of the nozzle.
Honeywell Titan SCBA, 20132 XII. fUNCTIONAL TESTING TABLE COMPONENT INSTRUCTIONS 1. Don and adjust the facepiece. 2. Block the AIR KLIC opening with the palm of your hand. FACEPIECE 3. Inhale gently. The facepiece should collapse slightly and hold for a few seconds without leaking.
Honeywell Titan SCBA, 20132 NOTE This section must be read in conjunction with the NIOSH approval label in this user’s manual. Failure to observe these cautions and limitations voids NIOSH approval. CAUTIONS AND LIMITATIONS D - Air line respirators can be used only when the respirators are supplied with respirable air meeting the requirements of CGA G-7.1 Grade D or higher.