Table of Contents
GE Healthcare
MAC™ ECG Trolley
Service Manual
2044854-012 Revision E
MAC™ ECG Trolley
English
© 2011-2013 General Electric Company.
All Rights Reserved.
Table of Contents
loading

Summary of Contents for GE Modular MAC Trolley

  • Page 1 GE Healthcare MAC™ ECG Trolley Service Manual 2044854-012 Revision E MAC™ ECG Trolley English © 2011-2013 General Electric Company. All Rights Reserved.
  • Page 2 MAC and CAM are trademarks owned by GE Medical Systems Information Technologies, Inc., a General Electric Company going to market as GE Healthcare. All other trademarks contained herein are the property of their respective owners.
  • Page 3 Service Manual Language Information (cont'd.) UPOZORENJE Ove upute za servisiranje dostupne su samo na engleskom jeziku. (HR) • Ukoliko korisnički servis zahtijeva neki drugi jezik, korisnikova je odgovornost osigurati odgovarajući prijevod. • Nemojte pokušavati servisirati opremu ukoliko niste konzultirali i razumjeli ove upute. •...
  • Page 4 Ez a szerviz kézikönyv kizárólag angol nyelven érhető el. FIGYELMEZTETÉS • (HU) Ha a vevő szerviz ellátója angoltól eltérő nyelvre tart igényt, akkor a vevő felelőssége a fordítás elkészíttetése. • Ne próbálja elkezdeni használni a berendezést, amíg a szerviz kézikönyvben leírtakat nem értelmezték és értették meg.
  • Page 5 Service Manual Language Information (cont'd.) AVVERTENZA Il presente manuale di manutenzione è disponibile soltanto in Inglese. (IT) • Se un addetto alla manutenzione richiede il manuale in una lingua diversa, il cliente è tenuto a provvedere direttamente alla traduzione. • Si proceda alla manutenzione dell'apparecchiatura solo dopo aver consultato il presente manuale ed averne compreso il contenuto.
  • Page 6 Este manual de assistência técnica só se encontra disponível em inglês. (PT-BR) • Se o serviço de assistência técnica do cliente não for GE, e precisar de outro idioma, será da responsabilidade do cliente fornecer os serviços de tradução. •...
  • Page 7 Service Manual Language Information (cont'd.) VAROVANIE Tento návod na obsluhu je k dispozícii len v angličtine. (SK) • Ak zákazníkov poskytovateľ služieb vyžaduje iný jazyk ako angličtinu, poskytnutie prekladateľských služieb je zodpovednosťou zákazníka. • Nepokúšajte sa o obsluhu zariadenia skôr, ako si neprečítate návod na obsluhu a neporozumiete mu.
  • Page 8 Service Manual Language Information (cont'd.) ЗАСТЕРЕЖЕННЯ Дане керівництво з сервісного обслуговування постачається виключно англійською мовою. (UK) • Якщо сервісний інженер потребує керівництво іншою мовою, користувач зобов'язаний забезпечити послуги перекладача. • Не намагайтеся здійснювати технічне обслуговування даного обладнання, якщо ви не читали, або не зрозуміли інформацію, надану в керівництві з сервісного обслуговування.
  • Page 9: Table Of Contents

    Field Replaceable Units (FRUs) ..............33 Modular MAC Trolley 2W Swivel Caster FRU Kit, PN 2056235-001 ......33 Modular MAC Trolley 4W Swivel Caster FRU Kit, PN 2056854-001 .
  • Page 10 Front Bumper FRU Kit, PN 2056236-001 ............36 Modular MAC Trolley Base, 2W Swivel Assy FRU Kit, PN 2056476-001 ..... 36 MAC 1600 Trolley Base, FRU Kit, PN 2056477-001 .
  • Page 11: Introduction

    Introduction This manual provides component, maintenance, and servicing information on the MAC ECG Trolleys. Intended Use The MAC ECG Trolley will provide a means whereby MAC ECG Analysis Systems can be transported within a hospital, clinic, or physician office setting. Additionally, the trolley will be used to transport all supplies and accessories used by clinicians to prepare patients for the ECG exam, acquire ECG data, and transmit ECG data to a storage system.
  • Page 12 Introduction PN 2055478–001 Modular MAC Trolley PN 2055479–001 Modular MAC Trolley Fully assembled Partially assembled 2 swivel, 2 non-swivel casters 2 swivel, 2 non-swivel casters Front Bin Rear Bin CAM14 Acquisition Flex Arm PN 2055853–001 MAC 1600 Trolley Partially assembled...
  • Page 13: Manual Information

    This section provides information for the correct use of this manual. Keep this manual with the equipment at all times and review it periodically. You should request training assistance from GE Healthcare, if needed. Intended Audience The MAC™ ECG Trolley Service Manual is intended for use by the following personnel: •...
  • Page 14 Introduction 2044854-012E MAC™ ECG Trolley...
  • Page 15: Equipment Overview

    Equipment Overview This chapter provides an overview of the MAC ECG Trolleys and available accessories. Physical Characteristics This section describes the physical characteristics of the Modular MAC Trolley and the MAC1600 Trolley. Modular MAC Trolley Characteristics The following image shows an assembled Modular MAC Trolley without bins or accessories.
  • Page 16: Mac 1600 Trolley Characteristics

    Equipment Overview Specifications for the Modular MAC Trolley (cont'd.) Feature Specification Handle Height 36.60 inches (92.96 cm) from the floor Handle Height (shortened column) 33.60 inches (85.34 cm) from the floor Static Control Floors should be wood, concrete, or ceramic tile.
  • Page 17: Accessories

    Assembly Value Acquisition Optional Optional Optional Arm/Bracket Assembly NEHB Acquisition Optional Optional Optional Arm/Bracket Assembly Modular MAC Trolley Optional Optional Not available Short Column MAC 1600 Short Not available Not available Optional Column KISS Mounting Collar Not Available Optional Not Available...
  • Page 18 Equipment Overview 2044854-012E MAC™ ECG Trolley...
  • Page 19: Maintenance

    Maintenance Regular maintenance, irrespective of usage, is essential to ensure that the equipment will always be functional when required. WARNING: Failure on the part of all responsible individuals, hospitals or institutions, employing the use of this device, to implement the recommended maintenance schedule may cause equipment failure and possible health hazards.
  • Page 20: Fru (Field Replaceable Units) Replacement Procedures

    Maintenance FRU (Field Replaceable Units) Replacement Procedures NOTE: For installation or replacement of accessories, refer to the trolley's assembly instructions. Refer to “Related Documents” on page 13 for a list of the assembly instructions. Always perform the following steps before tipping the trolley for maintenance. Disconnect power cables.
  • Page 21 Maintenance Modular MAC Trolley MAC 1600 Trolley 2044854-012E MAC™ ECG Trolley...
  • Page 22: Removing The Mac Unit From The Modular Mac Trolley

    The MAC device should be removed from the trolley for service and/or maintenance procedures. For this procedure, you will need a #2 Phillips screwdriver. To remove the MAC unit from the Modular MAC Trolley, use the following procedure: Use a #2 Phillips screwdriver to remove the two PHMS screws that secure the MAC mounting plate to the molded top.
  • Page 23: Removing The Mac Unit From The Mac 1600 Trolley

    Maintenance Using the #2 Phillips screwdriver, insert the two PHMS screws that secure the molded top to the underside of the MAC mounting plate. Replace the equipment that was removed and reconnect power cables to the equipment on the trolley. Removing the MAC Unit from the MAC 1600 Trolley The MAC device should be removed from the trolley for service and/or maintenance procedures.
  • Page 24: Replacing The Modular Or Mac 1600 Top

    This procedure applies to all trolley styles. Before removing the top from the trolley column, the MAC unit needs to be removed. “Removing the MAC Unit from the Modular MAC Trolley” on page 22 for instructions on removing the MAC from the Modular MAC Trolley. See “Removing the MAC Unit...
  • Page 25: Replacing The Front Bumper

    This procedure applies to all trolley styles. For this procedure, you will need a #20 Torx screwdriver. To remove the bumper from the Modular MAC Trolley, use the following procedure: Using the T-20 Torx screwdriver, remove the four screws from the underside of the bumper.
  • Page 26: Replacing The Trolley Base

    This procedure applies to all trolley styles. Before removing the base, remove the MAC unit and accessories from the trolley. See “Removing the MAC Unit from the Modular MAC Trolley” on page 22 for instructions on replacing the MAC unit to the Modular MAC Trolley. See “Removing the MAC Unit...
  • Page 27 Maintenance Once the MAC unit is removed, use the following instructions to replace the base. Remove the bins and carefully lay the trolley assembly flat on its back on a smooth, padded surface. This will avoid scratches or other damage to the trolley. Using the 1/2"...
  • Page 28: Replacing The Base Cover

    Using a #25 Torx screwdriver, insert the 4 Plastite screws that secure the base cover to the base. Replacing Casters on the Modular MAC Trolley This procedure applies only to the Modular MAC Trolley. For instructions on removing the casters from the MAC 1600 Trolley, refer to “Replacing Casters on the MAC 1600 Trolley”...
  • Page 29: Replacing Casters On The Mac 1600 Trolley

    Reattach the MAC device and trolley options. Replacing Casters on the MAC 1600 Trolley This procedure applies only to the MAC 1600 Trolley. For instructions on removing the casters from the Modular MAC Trolley, refer to “Replacing Casters on the Modular MAC Trolley” on page Before removing the base, remove the MAC unit and accessories from the trolley.
  • Page 30: Replacing The Anti-Static Strap

    Reattach the device and the trolley options. Replacing the Anti-Static Strap This procedure applies to all trolley styles. Remove the MAC unit from the trolley. For the Modular MAC Trolley, see “Removing the MAC Unit from the Modular MAC Trolley” on page 22 for instructions.
  • Page 31 Maintenance Lower the weighted end of the ESD Braid through the designated opening, as shown in the following illustration. Position the ESD Braid’s eyelet, washer, and screw as shown in the following illustration. 2044854-012E MAC™ ECG Trolley...
  • Page 32: Functional Checkout

    For both trolley types, see “Replacing the Trolley Base” on page 26 instructions. Reattach the MAC unit to the trolley. For the Modular MAC Trolley, see “Removing the MAC Unit from the Modular MAC Trolley” on page 22 for instructions.
  • Page 33: Parts Lists

    FRUs, and FRU kits considered to be field servicable. Only items assemblies and kits which have part numbers given in this chapter are available for purchase as FRUs. To order parts, contact GE Healthcare Service Parts. Field Replaceable Units (FRUs) The Field Replacement Unit (FRU) list contains information on which parts are considered serviceable.
  • Page 34: Modular Mac Trolley 4W Swivel Caster Fru Kit, Pn 2056854-001

    Parts Lists Modular MAC Trolley 4W Swivel Caster FRU Kit, PN 2056854-001 Modular MAC Trolley 4W swivel Caster FRU Kit, PN 2056854-001 Item Part Description 5327 Series Tente, Swvl, braking, 125mm 5327 Series Tente Swvl. No Lk, 125mm Screw M8 x 1.25, 20mm...
  • Page 35: Modular Mac Trolley 2W Caster Swivel Fru Kit, Pn 2075199-001

    5327 Series Tente Swvl. No Lk, 125mm Modular MAC Trolley 2W Swivel Caster with Brakes FRU Kit, PN 2076629-001 Modular MAC Trolley 2W Swivel Caster with Brakes FRU Kit, PN 2076629-001 Item Part Description 5327 Series Tente Swvl, braking, 125mm Screw M8 x 1.25, 20mm...
  • Page 36: Front Bumper Fru Kit, Pn 2056236-001

    Part Description Rear Bumper, Top Housing Screw #8-16 x 5/8 Pan Head Torx Modular MAC Trolley Base, 2W Swivel Assy FRU Kit, PN 2056476-001 Modular MAC Trolley Base, 2W Swivel Assy FRU Kit, PN 2056476-001 Item Part Description Base Assy 2044854-012E...
  • Page 37: Mac 1600 Trolley Base, Fru Kit, Pn 2056477-001

    Parts Lists MAC 1600 Trolley Base, FRU Kit, PN 2056477-001 MAC 1600 Trolley Base, FRU Kit, PN 2056477-001 Item Part Description MAC 1600 base assy Not shown 1/2 inch Socket Wrench Top Housing Assy FRU Kit, PN 2056244-001 Top Housing Assy FRU Kit, PN 2056244-001 Item Part Description Top housing Assy...
  • Page 38: Dual Lock (Velcro) Kit, Pn 2056811-001

    Parts Lists Dual Lock (Velcro) Kit, PN 2056811-001 Dual Lock (Velcro) Kit, PN 2056811-001 Item Part Description 1" square velcro 2044854-012E MAC™ ECG Trolley...
  • Page 39: Fastener Hardware Fru Kit, Pn 2056473-001

    Parts Lists Fastener Hardware FRU Kit, PN 2056473-001 Identify the appropriate fastener in the following photographs and use the associated number to locate the corresponding item description in the table “Fastener Hardware FRU Kit, PN 2056473-001”. The photographs are to scale. 2044854-012E MAC™...
  • Page 40 Modular MAC Trolley. 2055443-001 HOLE PLUG, CIRCULAR, SNAP-IN Plugs the opening in the bottom of the wireless bin of the Modular MAC Trolley. 2055446-001 #10-32 x 3" PHMS Attaches the ECG mounting plate to the top of the Modular MAC Trolley.
  • Page 41 2056525-001 Attaches the cover of the 8-32 x 1/4 FHMS 100 DEG, SS wireless device bin to the top of the Modular MAC Trolley. 2057017-001 NYLON HOLE PLUG Plugs the screw holes in the wireless device bin on the top of the Modular MAC Trolley.
  • Page 42: Accessories

    Parts Lists Accessories The accessories list contains information on optional parts available for the MAC trolleys. Front Bin, PN 2056228-001 Front Bin, PN 2056228-001 Item Part Description Cleat, Bin Mounting Screw 1/4-20 Stainless Steel Front Bin, 2044854-012E MAC™ ECG Trolley...
  • Page 43: Rear Bin, Pn 2056230-001

    Parts Lists Rear Bin, PN 2056230-001 Rear Bin, PN 2056230-001 Item Part Description Cleat, Bin Mounting Screw 1/4 - 20 Stainless Steel Rear Bin 2044854-012E MAC™ ECG Trolley...
  • Page 44: Barcode Holder, Pn 2056240-001

    Parts Lists Barcode Holder, PN 2056240-001 Barcode Holder, PN 2056240-001 Item Part Description Barcode Bracket SCREW MACH BUTTON HD 3/8"-16 x 1.5" LONG 2044854-012E MAC™ ECG Trolley...
  • Page 45: Cam14 Acquisition Arm/Bracket Assembly, Pn 2056231-001

    Parts Lists CAM14 Acquisition Arm/Bracket Assembly, PN 2056231-001 CAM14 Acquisition Arm/Bracket Assembly, PN 2056231-001 Item Part Description CAM14 Acquisition Holder SCREW MACH BUTTON HD 3/8"-16 x 1.5" LONG Plastic clips 2044854-012E MAC™ ECG Trolley...
  • Page 46: Multi-Link Acquisition Arm/Bracket Assembly, Pn 2056233-001

    Parts Lists Multi-Link Acquisition Arm/Bracket Assembly, PN 2056233-001 Multi-Link Acquisition Arm/Bracket Assembly, PN 2056233-001 Item Part Description Multi—Link Acquisition Holder SCREW MACH BUTTON HD 3/8"-16 x 1.5" LONG Plastic clips 2044854-012E MAC™ ECG Trolley...
  • Page 47: Value Acquisition Arm/Bracket Assembly, Pn 2056234-001

    Parts Lists Value Acquisition Arm/Bracket Assembly, PN 2056234-001 Value Acquisition Arm/Bracket Assembly, PN 2056234-001 Item Part Description Value Acquisition Holder SCREW MACH BUTTON HD 3/8"-16 x 1.5" LONG Plastic clip 2044854-012E MAC™ ECG Trolley...
  • Page 48: Nehb Acquisition Arm/Bracket Assembly, Pn 2056232-001

    Parts Lists NEHB Acquisition Arm/Bracket Assembly, PN 2056232-001 NEHB Acquisition Arm/Bracket Assembly, PN 2056232-001 Item Part Description NEHB Acquisition Holster SCREW MACH BUTTON HD 3/8"-16 x 1.5" LONG Plastic clips 2044854-012E MAC™ ECG Trolley...
  • Page 49: Modular Mac Trolley Short Column, Pn 2056478-001

    Parts Lists Modular MAC Trolley Short Column, PN 2056478-001 Modular MAC Trolley Short Column, PN 2056478-001 Item Part Description Modular MAC Trolley Short Column MAC 1600 Trolley Short Column, PN 2056479-001 MAC 1600 Trolley Short Column, PN 2056479-001 Item Part Description...
  • Page 50: Mac 1600 Acquisition Mounting Bracket, Pn 2057392-001

    Parts Lists MAC 1600 Acquisition Mounting Bracket, PN 2057392-001 MAC 1600 Acquisition Mounting Bracket, PN 2057392-001 Item Part Description MAC 1600 Acquisition Bracket Screw 3/8 — 16 x 0.5” Not shown 1/8” Allen Wrench Modular MAC KISS Mounting Collar, PN 2056239-001 Modular MAC KISS Mounting Collar, PN 2056239-001 Item Part Description...
  • Page 51: Kiss Pump Bracket, Pn 2057374-001

    Parts Lists KISS Pump Bracket, PN 2057374-001 KISS Pump Bracket, PN 2057374-001 Item Part Description KISS Pump Bracket Screw 1/4 — 20 x 3/4” Wireless Cover Bracket Kit, PN 2056227-001 Wireless Cover Bracket Kit, PN 2056227-001 Item Part Description Wireless Cover Screws 8 —...
  • Page 52 Parts Lists 2044854-012E MAC™ ECG Trolley...
  • Page 54 +49 761 45 43 -233 Shanghai, People's Republic of China 201203 Fax: +1 414 355 3790 Tel: +86 21 3877 7888 Fax: +86 21 3877 7451 GE Medical Systems Information Technologies, Inc., a General Electric Company, going to market as GE Healthcare. www.gehealthcare.com...

This manual is also suitable for:

2055478-0012055479-0012055853-001Mac 1600

Table of Contents