Page 2
électrique, d’incendie ou de blessure n’effectuer que les réparations indiquées dans le mode d’emploi à moins d’être qualifié pour en effectuer d’autres. Pour toute réparation faire appel à une personne compétente uniquement. BDX-E1000 Serial No. 10001 and Higher BDKP-E1002 Serial No.
Page 3
For the U.S.A. Attention-when the product is installed in Rack: (For BDX-E1000) 1. Prevention against overloading of branch circuit When this product is installed in a rack and is supplied power from an outlet on the rack, please make sure that the rack does not overload the supply circuit.
Manual Structure Purpose of this manual This manual is the installation manual of the BDX-E1000 MPEG Encoder Unit and the following optional boards. . Audio Input Board BDKP-E1002 . 4:2:2 Profile Upgrade Board BDKP-E1003 . Scrambler Board BDKP-E1004 . Scrambler Board...
E1000, pay careful attention to circulation of air in the place where the BDX-E1000 is installed. The rear side of the BDX-E1000 should be at least Power cord for the customer in the United Kingdom. 20 cm away from walls for ventilation and 1 DK-2401 (UK) (approx.
The BDX-E1000 can be mounted in a 19-inch standard rack. • If the BDX-E1000 or the peripheral equipment is mounted in a 19-inch standard rack, it is recommend- ed to install a ventilation fan to prevent a temperature rise in the rack.
Page 11
Be sure to use the RMM-30 rack mount rail. 4. Attach the inner rails to the BDX-E1000 using the six screws (B4 X 8) supplied with the BDX-E1000. If a rack mount rail other than the RMM-30 is used, the BDX-E1000 may be dropped by insufficient strength of the rack mount rail.
Page 12
581 (Maximum traveling distance) Stopper Inner rail Distance to the center of the slide rail • Be sure to mount the BDX-E1000 in the rack with two or more persons. Height of the unit mounted in a rack Unit : mm Trying to handle this job by one-person could occur to injury.
When connecting cables to various connectors on the rear panel at the time of installing or servicing, connect the following connectors/cables or their equivalents. BDX-E1000 Matching Connector/Cable Panel Indication Connector/Cable Sony Part No. BNC 75 Ω, male VIDEO INPUT 1-569-370-12 REF.VIDEO COMPOSITE COMPONENT BNC 75 Ω, male...
-DB(2) Data 4 B -DB(3) Data 3 B -DB(4) Data 2 B -DB(5) Data 1 B -DB(6) Data 0 B -DB(7) DVALID B (=Data valid B) -DB(P) PSYNC B (=Packet sync B) – To be continued. – 1-6 (E) BDX-E1000...
20 dB 18 dB 16 dB Serial number 10031 and higher : Not mounted S102(H-13) 20 S905 (G-10) : Factory use only S202(H-11) 20 Factory setting : ON S302(H-10) 20 S402(H-9) n Be sure to use this switch with factory setting. 1-8 (E) BDX-E1000...
The correspondence of the indicator and the channel are as Lights up when the stream buffer is filled to capacity. follows: D1414 (A-8) (green) : STREAM BUFFER indicator D917 D918 D919 D920 D921 D922 D923 D924 Lights up when the stream buffer is empty. 1-9 (E) BDX-E1000...
OPEN : Resume mode CLOSE : Host control mode Factory setting : CLOSE (lower position) Before selecting the resume function, be sure to set S202 to “0”. 1-10 (E) BDX-E1000...
Page 19
Lights up when the lithium battery (B101) for data backup If a digital composite signal is input in Digital runs down. Component mode, a system error will result. D106 (A-4) (green) : POWER indicator Lights up during the power supply operates normally. 1-11 (E) BDX-E1000...
Lights up when the reference video signal is detected. • Input lock mode (Analog composite input/Analog component input modes): Lights up when selected input signal is detected. D15 (A-2) (green) : REFERENCE LOCK indicator Lights up during the reference lock mode. 1-12 (E) BDX-E1000...
3. Install the BZX-E1001 on the computer connected to the BDX-E1000, then set the mode as required. (Refer to the User’s Guide of BZX-E1001.) 4. Check the operation of the BDX-E1000, then stop it by using the BZX-E1001. (Refer to the User’s Guide of BZX-E1001.) 5.
BDX-D1000 MPEG Decoder Unit. 〈SY-240 board〉 S201 OPEN The transmission of the color frame information is possible with the BDX-E1000 of a serial number 20001 and higher. S201 S202 Procedures S202 A side (Component side) For details, refer to the User’s Guide of the optional...
BDKP-E1002 Audio Input Board When the BDKP-E1002 (DPR-93 board) is installed on the APR-25 board, it expands the digital audio input of the BDX-E1000 from 4-channels to 8-channels. BDKP-E1003 4:2:2 Profile Upgrade Board Front panel When the BDKP-E1003 (DEC-106 board) is installed on the ENC-40 board, it can be encoded by 4:2:2P@ML.
8. Tighten the locking screw. Installation procedures Confirmation after installation 1. Remove the APR-25 board from the BDX-E1000. (Refer to the Section 2-1.) 2. Fix the four PCB holders supplied with the BDKP- In this section, describes the DVR-2000/2100 (4:2:2 E1002 to the APR-25 board.
Page 25
2. Provide the SDI signal and the AES/EBU signal to 5. Check that the SDI input signal is output from the the BDX-E1000. monitor output connectors normally. : The SDI signal (CH5 to CH8) is output by the Switch settings (SY-240 board): menu setting of the DVR-2000/2100.
. SY-240 board : Board suffix -13 and higher . VPR-33 board : Board suffix -13 and higher DEC-106 board Installation procedures 1. Remove the ENC-40 board from the BDX-E1000. PCB holder (Refer to the Section 2-1.) 2. Fix the two PCB holders supplied with the BDKP- E1003 to the ENC-40 board.
8. Tighten the locking screw. Installation procedures Confirmation after installation 1. Remove the SY-240 board from the BDX-E1000. (Refer to the Section 2-1.) There is no necessity to confirm/adjust after SCR-4/5 2. Fix the two PCB holders supplied with the BDKP- board installing.
It is recommended to replace the filter every five years. • Filter (3U) : 2-139-072-03 Front panel Tape If the BDX-E1000 is kept on operating with too dusty of the filter, the temperature inside the unit getting rise. This may cause a fire. 1. Turn the power off.
3-2. Periodic Replacement 3-2. Periodic Replacement To maintain the performance of the BDX-E1000, it is Lithium battery recommended to replace the following parts periodically. For data backup, a lithium battery is installed on the SY- 240 board of the BDX-E1000.
3-3-2. Usage of ISR Functions The BDX-E1000 corresponds to the ISR function. The ISR function is controlled by Sony application Using this function, the status of the BDX-E1000 and the program software. contents of a generated error can be intensively monitored...
Page 32
3-3. ISR (Interactive Status Reporting) Information of ISR Connector Prepare a cable referred to the following connection. In case of direct connection with a personal computer Signal Signal DB25 Signal Signal 3-4 (E) BDX-E1000...
Page 33
3-3. ISR (Interactive Status Reporting) In case of connection with a host computer via LAN (Terminal Server: 6-pin port) The connection will change according to the maker of terminal server. Terminal Server RJ12 (Modular type) 3-5 (E) BDX-E1000...
3-3. ISR (Interactive Status Reporting) 3-3-3. Error Messages The register numbers and the messages supported by the BDX-E1000 are as follows. Register No. Message Remedy FAN ERROR Replace the fan motor. VPR-33 BOARD ERROR Replace the VPR-33 board. ENC-40 BOARD ERROR Replace the ENC-40 board.
Page 35
The material contained in this manual consists of information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation.