Bosch ARD-AYCE65B Installation Manual

Bosch ARD-AYCE65B Installation Manual

Rfid - proximity card reader

Quick Links

ARD-AYCE65B
RFID - Proximity Card Reader
en
Installation manual
Table of Contents
loading

Summary of Contents for Bosch ARD-AYCE65B

  • Page 1 ARD-AYCE65B RFID - Proximity Card Reader Installation manual...
  • Page 3: Table Of Contents

    Key Features Installation Mounting the ARD-AYCE65B Wiring Instructions Reader Functionality Transmit Mode Programming the ARD-AYCE65B Series Selecting Keypad Transmission Format 5.3.1 Option No. 1: Single Key, 6-Bit Wiegand 5.3.2 Option No. 2: Single Key, 6-Bit Wiegand Nibble and Parities 5.3.3 Option No.
  • Page 4 | Table of Contents ARD-AYCE65B Appendix LED displays Technical Support | V 1.1 | 2009.08 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 5: General Information

    ARD-AYCE65B General Information | en General Information Introduction The ARD-AYCE65B family is an Ultra-slim, vandal-resistant, Piezo Mullion Keypad, access control reader. The unit is vandal resistant and water resistant, suitable for indoor or outdoor mounting. This manual contains the following information: –...
  • Page 6: Technical Specifications

    Environmental Characteristics Operating temp. range -30 to 65° C (-22 to 150° F) Operating humidity 0 - 95% (non-condensing) Outdoor usage Weather-resistant, meets IP-68, epoxy potted, suitable for outdoor Mechanical | V 1.1 | 2009.08 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 7: Key Features

    *Measured using Bosch proximity card (ACD-ATR14CS) or equivalent. Range also depends on electrical environment and proximity to metal. Key Features The key features for the ARD-AYCE65B series are: – Ultra-Slim Flush-mount design on flat surface – Built-in piezoelectric keypad for PIN code entry –...
  • Page 8: Installation

    Figure 3.1 Drilling & Mounting Template Route the interface cable from the ARD-AYCE65B to the controller. A linear type power supply is recommended. Screw the ARD-AYCE65B to its mounting location or US gang box. | V 1.1 | 2009.08 Installation manual...
  • Page 9: Wiring Instructions

    LED Control / Auxiliary Input Tamper Purple Tamper If the tamper output is used, connect the purple wire to the correct input on the controller. Trim and cover all unused conductors. Bosch Sicherheitssysteme GmbH Installation manual | V 1.1 | 2009.08...
  • Page 10 This configuration is best for shielding the Reader cable from external interference Figure 4.1 Reader Application Wiring Diagram | V 1.1 | 2009.08 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 11: Reader Functionality

    Reader Functionality The following explains how to use the ARD-AYCE65B reader. Transmit Mode When the ARD-AYCE65B is in Transmit Mode, it is ready to receive data from a presented Proximity Card or an entered PIN code. When the reader is in Transmit Mode, the Transmit LED is red and the Program LED is off.
  • Page 12 Changing the Facility Code Backlight Options On (Default) Off until key press when on for 10 seconds Dimmed until key press when on for 10 seconds Return to Factory Default Settings | V 1.1 | 2009.08 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 13: Selecting Keypad Transmission Format

    – The Program LED will be off – The Transmit LED will turn red This indicates that the ARD-AYCE65B has returned to Transmit Mode. Wrong entries may reset the reader back to Transmit Mode. While in Programming Mode if no key is pressed for 30 seconds the ARD-AYCE65B will exit Programming Mode and return to Transmit Mode.
  • Page 14 1 to 5 Keys + Facility Code, 26-Bit Wiegand 6 Keys BCD and Parity Bits, 26-Bit Wiegand Single Key, 3x4 Matrix Keypad 1 to 8 Keys BCD, Clock & Data Single Key | V 1.1 | 2009.08 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 15: Option No. 1: Single Key, 6-Bit Wiegand

    2 = 000100 8 = 110001 3 = 000111 9 = 110010 4 = 101001 ? = 110100 ="A" * 5 = 101010 # = 110111 ="B" * * = Hexadecimal Bosch Sicherheitssysteme GmbH Installation manual | V 1.1 | 2009.08...
  • Page 16: Option No. 3: Single Key, 8-Bit Wiegand Nibbles Complemented

    5 seconds, the keypad will clear the PIN code entry buffer, generate a beep and is ready to receive a new 4 digits keypad PIN code. (EP) FFFF FFFF AAAA AAAA AAAA AAAA (OP) | V 1.1 | 2009.08 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 17: Option No. 5: 1 To 5 Keys + Facility Code, 26-Bit Wiegand

    PIN code entry buffer, generate a medium length beep and is ready to receive a new 1 to 5 digit keypad PIN code. (EP) FFFF FFFF AAAA AAAA AAAA AAAA (OP) Where: Bosch Sicherheitssysteme GmbH Installation manual | V 1.1 | 2009.08...
  • Page 18: Option No. 6: 6 Keys Bcd And Parity Bits, 26-Bit Wiegand

    Even parity for first 12 bits Odd parity for last 12 bits First key entered Fourth key entered Second key entered Fifth key entered Third key entered Sixth key entered | V 1.1 | 2009.08 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 19: Option No. 7: Single Key, 3X4 Matrix Keypad (Ard-Mdp64)

    MDP64) This unique mode is intended to let the host controller scan the ARD-AYCE65B keypad while still keeping the proximity card readers 26-Bit Wiegand or Clock & Data formats active. An optional interface board must be used between the ARD- AYCE65B and the host system.
  • Page 20: Selecting Proximity Card Transmission Format

    PIN code. Selecting Proximity Card Transmission Format The ARD-AYCE65B has three different proximity card formats to select from. Follow the steps below to select the appropriate Proximity Card reader transmission format that you wish to use.
  • Page 21: Wiegand Card + Pin" Transmission Format

    Keypad Transmission Format and sends the keypad data as described below. After a card is presented to ARD-AYCE65B, the program LED starts to flash in Green and indicates that ARD-AYCE65B is waiting for the PIN code. If the entry of one to five digit keypad...
  • Page 22: Changing The Programming Code

    NOTICE! – Programming Code can not be erased, i.e. the code 0000 is invalid and will not erase the Programming Code. – The factory default 4-digit Programming Code is 1234. | V 1.1 | 2009.08 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 23: Changing The Facility Code

    "3" for 10 sec. backlight after a key is pressed otherwise dimmed System returns to Transmit Mode – You will hear three beeps – The Transmit LED will turn red. Bosch Sicherheitssysteme GmbH Installation manual | V 1.1 | 2009.08...
  • Page 24: Return To Factory Default Settings

    Activate tamper by removing the reader from the wall or removing the reader's case. Apply power to the reader. You now have 10 seconds to enter Programming Mode using the factory default Programming Code 1234. | V 1.1 | 2009.08 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 25 1. Enter programming mode (green) (green) (red) 2. Press 2 3. Enter the no. for the prxy card transmission format. 4. Back to transmit mode. (red) and three beeps Changing the Programming code Bosch Sicherheitssysteme GmbH Installation manual | V 1.1 | 2009.08...
  • Page 26 Return to Factory Default Settings 1. Enter programming mode (green) (flash red) (flash red) 2. Press 0 3. Enter the 4 digit three beeps programming code 4. Back to transmit mode (red) | V 1.1 | 2009.08 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 27 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 585 223 4060 Fax: +1 800 289 0096 [email protected] http://www.boschsecurity.us Asia Pacific: Bosch Security Systems Pte Ltd. 38C Jalan Pemimpin Singapore 577180 Phone: +65 6319 3450 Fax: +65 6319 3499 [email protected] http://www.boschsecurity.com...
  • Page 28 | Appendix ARD-AYCE65B | V 1.1 | 2009.08 Installation manual Bosch Sicherheitssysteme GmbH...
  • Page 32 Bosch Sicherheitssysteme GmbH Robert-Koch-Straße 100 D-85521 Ottobrunn Germany Telefon +49 89 6290-0 +49 89 6290-1020 www.boschsecurity.com © Bosch Sicherheitssysteme GmbH, 2009...

Table of Contents