Sony NU-IP40S Instructions For Use Manual

Sony NU-IP40S Instructions For Use Manual

Ip converter

Quick Links

4-580-453-13(1)
2017-08
IP Converter
Instructions for Use
Before operating the unit, please read this manual thoroughly
and retain it for future reference.
NU-IP40S
© 2016 Sony Corporation
Table of Contents
loading

Summary of Contents for Sony NU-IP40S

  • Page 1 4-580-453-13(1) 2017-08 IP Converter Instructions for Use Before operating the unit, please read this manual thoroughly and retain it for future reference. NU-IP40S © 2016 Sony Corporation...
  • Page 2 Indications for Use/Intended Use This symbol indicates the manufacturer, and appears next to the manufacturer’s name and The Sony IP Converter’s (IPC) intended use is to address. distribute patient images acquired from modalities within a hospital or clinical environment in almost real- This symbol indicates the EU Importer, and time.
  • Page 3 IEC 60601-1 standards. If in doubt, consult qualified Sony service personnel. 3. Connecting the unit to other devices may increase the leakage current.
  • Page 4 Corporation, may result in increased emissions or decreased immunity of the NU-IP40S. Guidance and manufacturer’s declaration – electromagnetic emissions The NU-IP40S is intended for use in the electromagnetic environment specified below. The customer or the user of the NU-IP40S should assure that it is used in such an environment.
  • Page 5 Guidance and manufacturer’s declaration – electromagnetic immunity The NU-IP40S is intended for use in the electromagnetic environment specified below. The customer or the user of the NU-IP40S should assure that it is used in such an environment. IEC 60601 Immunity test Compliance level Electromagnetic environment –...
  • Page 6 RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the NU-IP40S is used exceeds the applicable RF compliance level above, the NU-IP40S should be observed to verify normal operation.
  • Page 7 Recommended separation distances between portable and mobile RF communications equipment and the NU-IP40S The NU-IP40S is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the NU-IP40S can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the NU-IP40S as recommended below, according to the maximum output power of the communications equipment.
  • Page 8 For the customers in Canada SONY LIMITED WARRANTY - Please visit http://www.sonybiz.ca/pro/lang/en/ca/article/resources-warranty for important information and complete terms and conditions of Sony’s limited warranty applicable to this product. For the customers in Europe Sony Professional Solutions Europe - Standard Warranty and Exceptions on Standard Warranty.
  • Page 9: Table Of Contents

    Indicators ............29 Table of Contents SYSTEM Indicator ..........29 LINK Indicator ............29 DIP Switch Settings ........30 Usage Precautions .........10 Introduction Features ............12 High-Quality 4K/HD Transmissions ....12 Low-Latency Network Transmissions ....12 High Reliability via Cable Redundancy ..... 12 Smooth Video Switching via Software ....
  • Page 10: Usage Precautions

     Strong magnetic fields the front panel indicator if the unit’s interior overheats. Failure to obey may result in unit deformation or If an error indication occurs, contact your local Sony damage. representative. Maintenance Pre-procedure verification Gently wipe dirt from the surface of the unit using a soft, Network transmissions via the unit entail image delays.
  • Page 11 In such Security cases, restart the unit. SONY WILL NOT BE LIABLE FOR DAMAGES OF ANY KIND RESULTING FROM A FAILURE TO Notes on video output IMPLEMENT PROPER SECURITY MEASURES ON...
  • Page 12: Introduction

    Features accessory (not supplied). Note The NU-IP40S IP Converter allows you to transmit 4K For details on supported monitors, refer to the or HD video and audio signals from a device equipped instructions for use for the IP converter bracket, or with 3G/HD-SDI video output via a high-speed optical contact your local Sony representative.
  • Page 13: System Configuration Examples

    Point-to-Multipoint Example You can connect a single sender to multiple receivers. This allows you to display the same images on multiple monitors. Same endoscopic images displayed Endoscopic device Optical network switch NU-IP40S NU-IP40S NU-IP40S (sender) (receiver) (receiver) SDI cable Optical fiber cable...
  • Page 14: Network System Manager Software Example

    Group 1 Group 0 Optical network Endoscopic Surgical camera Surgical camera Endoscopic Endoscopic device switch images images images NU-IP40S NU-IP40S NU-IP40S NU-IP40S NU-IP40S (sender) (sender) (receiver) (receiver) (receiver) SDI cable Optical fiber cable Video signal transmission Network System Manager Software Example When multiple senders and receivers are connected, you can use the Network System Manager software installed on a server computer to configure each IP converter remotely and send specified images to specified receivers.
  • Page 15: Parts Identification

    RS-232C connector (9-pin D-sub) Indicates the status of the unit. Control device connected to this connector remotely. For details, see “Indicators” (page 29). For details, contact your local Sony representative.  DC IN connector Connect the 24 V DC power cable here.
  • Page 16 Class I devices should only be connected to a power Do not connect any device other than one which outlet that is properly earthed to avoid the risk of electric conforms to IEC 60601-1 standards. shock. When an information technology device or AV device that uses an alternating current is connected, current For information on how to shut off the main power leakage may result in an electric shock to the patient or...
  • Page 17: Operations

    Operations Notes Disconnect the DC power cable before configuring  settings. The unit’s settings can be configured remotely via the  Changes to settings will be applied the next time the network or manually via the unit’s DIP switches. unit turns on. Remote settings configuration requires a server computer connected to the network and the Network System Manager software (not supplied).
  • Page 18: Downconvert Output Settings

    DIP switch 1 DIP switch 1 Input video Input video 3G-SDI Output video resolution resolution format mapping format 1920×1080 – 1920×1080 /50i Same as input video resolution – 1920×1080 – /59.94i 3840×2160 Resolution converted 1920×1080 (1920×1080) Level A/B /50p – –...
  • Page 19: Compression Mode Settings

    Note DIP switch 3 3D video conversion Dynamic IP address assignment using DHCP is not supported during manual configuration mode. During 3G Quad SQ input, the line-by-line format is detected automatically and converted to top-and-bottom before transmitting and output. Compression Mode Settings When line-by-line auto-detection does not function during 3G Quad SQ input, conversion Configure the compression mode (compressed or...
  • Page 20: Connection Examples

    Connection Examples Connection Example 1 (4K Video Transmission) When transmitting 4K video, connect the SDI cables to all the SDI input/output connectors. 4K endoscopic Optical network 4K monitor device switch SDI cable ×4 SDI cable ×4 Sender (IPC1) Receiver (IPC2) Optical fiber cable Video signal transmission DIP switch settings...
  • Page 21: Connection Example 2 (Hd Video Transmission, Network Redundancy Disabled)

    Setting Sender (IPC1) Receiver (IPC2) 3840×2160/50p Input video format – Level A 4K 2-SI 2D Output video format – 3840×2160/50p Video transmission group Group 0 Group 0 192.168.10.32 192.168.10.100 IP address 192.168.11.32 192.168.11.100 Compression mode Compressed – Network redundancy Enabled Enabled 3D video Automatically determined...
  • Page 22: Connection Example 3 (Multipoint-To-Multipoint, Video Transmission Group Setting)

    Setting not required The DIP switch settings will result in the following configurations. Setting Sender (IPC1) Receiver (IPC2) Input video format 1920×1080/59.94i – Output video format – 1920×1080/59.94i Video transmission group Group 3 Group 3 192.168.10.32 192.168.10.100 IP address 192.168.11.32 192.168.11.100 Compression mode Uncompressed...
  • Page 23 DIP switch settings DIP switch 1 DIP switch 2 DIP switch 3 Sender (IPC1) Sender (IPC2) Receiver (IPC3) Receiver (IPC4) Receiver (IPC5) Setting not required The DIP switch settings will result in the following configurations. Setting Sender (IPC1) Sender (IPC2) Receiver (IPC3) Receiver (IPC4) Receiver (IPC5)
  • Page 24: Miscellaneous

    Network synchronization in sender. If the problem does not resolve itself after a UNLOCK(TX) Blinking (green) progress (sender) moment, contact your local Sony representative. Network synchronization is in progress on the NU-IP40S: Network synchronization in receiver. If the problem does not resolve itself after a...
  • Page 25: Troubleshooting

    Check that the SDI connectors at the rear of the CD-ROM. unit are connected properly (page 15). For details on source codes, contact your local Sony  Check the DIP switch settings. The DIP switches representative. Please refrain from inquiries about the must be configured according to the output video contents of the source codes.
  • Page 26: Specifications

    700 hPa to 1,060 hPa  Always verify that the unit is operating properly Storage and transport conditions before use. SONY WILL NOT BE LIABLE FOR Temperature DAMAGES OF ANY KIND INCLUDING, BUT –20 °C to +60 °C (–4 °F to +140 °F)
  • Page 27: Dimensions

    Dimensions 180 (7 (unit: mm (in.))
  • Page 28: Supported Input Signals

    Supported Input Signals The unit supports the following signal formats. Signal formats HD-SDI 1920×1080/59.94i 4:2:2YCbCr 10-bit 1920×1080/50i 4:2:2YCbCr 10-bit 3G-SDI 1920×1080/59.94p 4:2:2YCbCr 10-bit Level A/Level B-DL 1920×1080/50p 4:2:2YCbCr 10-bit Level A/Level B-DL 1920×1080/59.94i 4:2:2YCbCr 10-bit Level B-DS 3D-Dual Stream 1920×1080/50i 4:2:2YCbCr 10-bit Level B-DS 3D-Dual Stream...
  • Page 29: Indicators

    Blinks 3 times (orange) Other error Blinks 4 times (orange) If the indicator does not light (green) after turning the power on, contact a technician or your local Sony representative. Buzzer In addition to the SYSTEM indicator, a buzzer sound is emitted as a notification if a fan error is detected at unit startup.
  • Page 30: Dip Switch Settings

    DIP Switch Settings When performing remote configurations via a network, set all the DIP switches to their OFF (i.e., factory default) positions. DIP switch 1 (: Necessary; –: Not necessary) Number Setting Description Sender Receiver Operation setting Always set to ON. OFF: Transmit compressed images.
  • Page 31 DIP switch 2 (: Necessary; –: Not necessary) Number Setting Description Sender Receiver OFF: Operate as a receiver.   Operation setting ON: Operate as a sender. Video transmission group and sender IP   [2] - [3] Refer to the following section. address settings System Always set to OFF.
  • Page 32 DIP switch 3 (: Necessary; –: Not necessary) Number Setting Description Sender Receiver [1], [3], [4] System Always set to OFF. – – OFF: Disable the frame buffer on the sender side. ON: Reduce the distortion that occurs immediately after video input starts using the frame buffer function on the sender side.
  • Page 33 Sony Corporation 1-7-1 Konan Minato-ku Tokyo, 108-0075 Japan...