ABB Welcome H8138.T Series Product Manual

ABB Welcome H8138.T Series Product Manual

Ip touch 5" outdoor station

Quick Links

2TMD041800D0006 │ 27.8.2020
Product manual
ABB-Welcome IP
H8138.T-. IP touch 5" outdoor station
Table of Contents
loading

Summary of Contents for ABB Welcome H8138.T Series

  • Page 1 2TMD041800D0006 │ 27.8.2020 Product manual ABB-Welcome IP H8138.T-. IP touch 5" outdoor station...
  • Page 2: Table Of Contents

    Inha ltsv erzeichnis Notes on the instruction manual ......................4 Safety ..............................4 Intended use ............................5 Environment ............................6 ABB devices ..........................6 Product description ..........................7 Device type ..........................7 Control elements........................8 Terminal description ........................9 Lock type and connection ......................10 Technical data ............................
  • Page 3 Inhaltsverzeichnis 10.1 Disclaimer ..........................38 10.2 Performance and service ......................38 10.3 Deployment guideline....................... 39 10.4 Upgrading..........................39 10.5 Backup/Restore ........................39 10.6 Malware prevention solution ..................... 39 10.7 Password rule .......................... 39 Notice ................................ 40 │3 Product manual 2TMD041800D0006...
  • Page 4: Notes On The Instruction Manual

    Please keep this manual in a safe place. If you pass the device on, also pass on this manual along with it. ABB accepts no liability for any failure to observe the instructions in this manual. Safety...
  • Page 5: Intended Use

    Intended use Intended use As part of the ABB-Welcome IP system, this device can only be used with accessories from that system. Security mode This outdoor station runs in "Security mode" by default to guarantee high security. In "Security mode", this outdoor station requires a certificate issued by the management software before it can function normally.
  • Page 6: Environment

    ABB devices All packaging materials and devices from ABB bear the markings and test seals for proper disposal. Always dispose of the packing materials and electric devices and their components via an authorized collection facility or disposal company.
  • Page 7: Product Description

    Product description Product description Device type Size (HxWxD) Article Product ID Product name Color number Unit: mm Stainless H81381T-S 2TMA130010X0009 IP touch 5" outdoor station 135 x 349 x 29 steel H81381T-W 2TMA130010W0013 IP touch 5" outdoor station White 135 x 349 x 29 │7 Product manual 2TMD041800D0006...
  • Page 8: Control Elements

    Product description Control elements Function Camera Speaker and microphone integration 5 inch touch display End strip │8 Product manual 2TMD041800D0006...
  • Page 9: Terminal Description

    Product description Terminal description Function Reset button Micro USB update connector Plug-in clamps (DC+...GND) for standalone power supply Plug-in clamps (LOCK...GND) for door opener Plug-in clamps (COM...NC...NO) for floating output, door opener LAN (PoE) Connector for next module Connector for exit button Connector for the sensor used for door status detection Connector for 5"...
  • Page 10: Lock Type And Connection

    Product description Lock type and connection Lock type Operation type Voltage Wiring type Electrical strike ⎓ Power on to open Type A/B 12 V lock, 12V Electrical strike ⎓ Power on to open Type B 24 V lock, 24V Electrical rim ⎓...
  • Page 11: Technical Data

    Technical data Technical data Designation Value ⎓ Rating voltage 24 V ⎓ Operating voltage range 20-27 V ⎓ 27 V , 410 mA Rating current ⎓ 24 V , 450 mA Operating temperature -20 °C…+55 °C Camera type CMOS Camera viewing angle 130°...
  • Page 12: Mounting/Installation

    Mounting/Installation Mounting/Installation Warning Electric voltage! Dangerous currents flow through the body when coming into direct or indirect contact with live components. This can result in electric shock, burns or even death. – Disconnect the mains power supply prior to installation and/or disassembly! –...
  • Page 13: Mounting

    Mounting/Installation Mounting 7.2.1 Preparation Use gloves to protect yourself against cuts. 7.2.2 Wiring │13 Product manual 2TMD041800D0006...
  • Page 14: Surface-Mounted Installation

    Mounting/Installation 7.2.3 Surface-mounted installation 40 mm 71 mm 7.2.4 Flush-mounted installation 1. Flush-mounted without pre-installation box 46 mm 117 mm │14 Product manual 2TMD041800D0006...
  • Page 15 Mounting/Installation 2. Flush-mounted with pre-installation box 126 m m 68 m m │15 Product manual 2TMD041800D0006...
  • Page 16: Cavity Wall Installation

    Mounting/Installation 7.2.5 Cavity wall installation │16 Product manual 2TMD041800D0006...
  • Page 17 Mounting/Installation Dismantling Note The following installation situations must be avoided without fail to ensure picture quality: ■ Direct light ■ Direct sunlight ■ Extremely bright picture background ■ Highly reflective walls on the opposite side of the door station ■ Lamps or direct light sources │17 Product manual 2TMD041800D0006...
  • Page 18: Commissioning

    Commissioning Commissioning Welcome screen and home screen This outdoor station will light up and display the welcome screen when someone approaches the station or if the station screen is touched. Click the bulletin to display it as full screen. Click the area (not the bulletin) to access the home screen (see the picture below on the right). Function Welcome message If there is no bulletin, the Welcome screen will display according to the welcome screen time.
  • Page 19: Entering The "Settings" Screen

    Commissioning Entering the "Settings" screen On the home screen, tap " ", followed by [#] [*] [engineering password] [#] to access ■ the "Settings" screen. Note The engineering password must be changed the first time you access engineering settings. (The system default is 345678. This password should only be used for initial setting work and should be changed to another password.
  • Page 20: Engineering Settings

    Commissioning Engineering settings On the "Settings" screen, tap "Engineering settings" to access the corresponding screen. Level 1 Level 2 Level 3 Option Block no. Outdoor station: 001...999 ■ Outdoor station Device type Device attribute ■ Gate station ■ Outdoor station: 01...64 Device no.
  • Page 21: Access Control Settings

    Commissioning Access control settings On "Settings" screen, tap "Access control" to access the corresponding screen. Level 1 Level 2 Level 3 Option ■ Private password ■ Off (default) Password ■ On, 3...8 digits Public password ■ Off (default) ■ On (default) Card mode Safe mode ■...
  • Page 22: System Settings

    Commissioning System settings On the "Settings" screen, tap "System settings" to access the corresponding screen. Level 1 Level 2 Level 3 Option Volume 1...5 Ringback volume 1...3 Ringtone ■ settings Voice prompts ■ Off (default) ■ On (default) Ringtone feedback ■...
  • Page 23 Commissioning Level 1 Level 2 Level 3 Option Lock-GND NO-NC-COM Subsidiary lock ■ Power lock (ID range: 1...32) IP actuator ■ Relay lock (ID range: 1...32) ■ Unlock type QR code unlock configuration ■ Off (default) Welcome screen time 1...60 s ■...
  • Page 24: Operating Door Entry System Devices

    Operating Door Entry System devices Operating Door Entry System devices Call a resident via keypad 9.1.1 Call a resident via the room number Precondition On the home screen, tap " ", followed by [#] [*] [engineering password] [#] to access ■...
  • Page 25: Call A Resident Via The Specified Code

    Operating Door Entry System devices 9.1.2 Call a resident via the specified code Precondition ■ On the home screen, tap " ", followed by [#] [*] [engineering password] [#] to access the "Settings" screen. On the "Settings” screen, complete the following settings: ■...
  • Page 26 Operating Door Entry System devices Initial a call using the specific code On the home screen, enter the specific code (e.g. A1), followed by " " to initiate a call. │26 Product manual 2TMD041800D0006...
  • Page 27: Call A Resident Via Address Book

    Operating Door Entry System devices Call a resident via address book Precondition On the home screen, tap " ", followed by [#] [*] [engineering password] [#] to access ■ the "Settings" screen. On the "Settings” screen, complete the following settings: "Engineering settings">>"System attribute">>"Default call type">>"Call from address book"...
  • Page 28 Operating Door Entry System devices Initial a call from address book On the home screen, tap a contact from the address book, followed by " " to initiate a call. │28 Product manual 2TMD041800D0006...
  • Page 29: Call Guard Unit

    Operating Door Entry System devices Call guard unit Precondition On the home screen, tap " ", followed by [#] [*] [engineering password] [#] to access ■ the "Settings" screen. On the "Settings” screen, complete the following settings: "Engineering settings">>"System attribute">>"Call guard unit">>"On">> enter the guard unit ■...
  • Page 30: Release The Lock By Entering A Password

    Operating Door Entry System devices Release the lock by entering a password 9.4.1 Release the lock by a password set on the indoor station Precondition On the home screen of the outdoor station, tap " ", followed by [#] [*] [engineering ■...
  • Page 31 Operating Door Entry System devices Release the lock by entering the password ■ On the home screen of the outdoor station, tap " ", enter [*] [address] [#] [password] [#], followed by " " to release the lock. – If call mode = physical and device type = outdoor station, [address] = room number –...
  • Page 32: Release The Lock By A Password Set On Local Outdoor Station

    Operating Door Entry System devices 9.4.2 Release the lock by a password set on local outdoor station Precondition On the home screen of the outdoor station, tap " ", followed by [#] [*] [engineering ■ password] [#] to access the "Settings" screen. On the "Settings”...
  • Page 33: Release The Lock By A Password Set On Welcome App

    Operating Door Entry System devices 9.4.3 Release the lock by a password set on Welcome App Precondition You need to create an unlock password on Welcome App. Please see the "Release the lock by a password set on Welcome App" chapter on the Welcome App manual for more details. Releasing the lock by entering a password On the "...
  • Page 34: Release The Lock By A Password Set On The Management Software

    Operating Door Entry System devices 9.4.4 Release the lock by a password set on the management software Precondition You need to create an unlock password on management software. Please see the management software manual for more details. Release the lock by entering a password On the "...
  • Page 35: Release The Lock By A Qr Code Set On Welcome App

    Operating Door Entry System devices Release the lock by a QR code set on Welcome App You need to pair Welcome App with an indoor station before this function is used. 1. Create an unlock QR code Please see the Welcome App product manual for more details. │35 Product manual 2TMD041800D0006...
  • Page 36 Operating Door Entry System devices 2. Use the unlock QR code on the outdoor station On the outdoor station, [1] On the home screen, tap " ", followed by enter [#] [*] [engineering password] [#] to access the "Settings" screen. [2] On the "Settings"...
  • Page 37: Releasing The Lock By Swiping Ic Cards

    Operating Door Entry System devices Releasing the lock by swiping IC cards Precondition On the home screen of the outdoor station, tap " ", followed by [#] [*] [engineering ■ password] [#] to access the "Settings" screen. On the "Settings” screen, complete the following settings: "Access control">>"Card mode">>"Safe mode">>"On"...
  • Page 38: Cyber Security

    H8138.T-. product, the network, its system and interfaces against any kind of security breaches, unauthorized access, interference, intrusion, leakage and/or theft of data or information. ABB and its affiliates are not liable for damages and/or losses related to such security breaches, unauthorized access, interference, intrusion, leakage and/or theft of data or information.
  • Page 39: Deployment Guideline

    Malware prevention solution The H8138.T-. device is not susceptible to malware, because custom code cannot be executed on the system. The only way to update the software is via firmware upgrades. Only firmware signed by ABB can be accepted. 10.7 Password rule The user must change the engineering password when accessing the engineering settings for the first time.
  • Page 40: Notice

    We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice. The detailed specifications agreed to at the time of ordering apply to all orders. ABB accepts no responsibility for possible errors or incompleteness in this document.
  • Page 41 Contact us Notice We reserve the right to at all times make technical changes as well as ABB Xiamen Smart Technology Co., Ltd. changes to the contents of this No.7, Fangshan South Road, Hi-tech area, Torch document without prior notice.

This manual is also suitable for:

Welcome h81381t-sWelcome h81381t-w

Table of Contents