Huawei UPS5000-E Series Quick Manual

Huawei UPS5000-E Series Quick Manual

Integrated ups 3.0
Hide thumbs Also See for UPS5000-E Series:

Quick Links

UPS5000-E-(50 kVA–125 kVA)
Quick Guide (Integrated UPS 3.0)
Issue: 06
Part Number: 31509228
Date: 2019-06-20
1
Overview
UPS Model
UPS5000-E-50K-HABBS
UPS5000-E-50K-HASBS
UPS5000-E-125K-HABBS
UPS5000-E-125K-HASBS
The appearance of the UPS5000-E-50K-HABBS (02311FTB-001) is similar to that of the
UPS5000-E-125K-HABBS (02311FTD-002).
The appearance of the UPS5000-E-50K-HASBS (02311FTC-001) is similar to that of the
UPS5000-E-125K-HASBS (02311FTE-002).
The appearance of the UPS5000-E-50K-HASBS (02311FTC-004) is similar to that of the
UPS5000-E-125K-HASBS (02311FTE-004)
UPS5000-E-50K-HABBS(02311FTB-001)
(1) Power input
status indicator
(3) Lighting
circuit breaker
(5) IT load circuit
breaker
(7) UPS maintenance
bypass circuit breaker
(9) Bypass module
(11) Power module
(13) Power distribution
monitoring board
Capacity
Configuration
50 kVA
125 kVA
(2) Input circuit
breaker
(4) Air conditioner power
distribution circuit
breaker
(6) UPS input
circuit breaker
(8) Control module
(10) Filler panel
(12) Monitor display unit
(MDU)
(14) UPS output
circuit breaker
Copyright © Huawei Technologies Co., Ltd. 2019. All rights reserved.
Weight (Full
Dimensions (H x W x D)
Configuration)
352 kg
390 kg
2000 mm x 600 mm x 1100
mm
435 kg
453 kg
1
Table of Contents
loading

Summary of Contents for Huawei UPS5000-E Series

  • Page 1 UPS5000-E-(50 kVA–125 kVA) Quick Guide (Integrated UPS 3.0) Issue: 06 Part Number: 31509228 Date: 2019-06-20 Copyright © Huawei Technologies Co., Ltd. 2019. All rights reserved. Overview Capacity Weight (Full UPS Model Dimensions (H x W x D) Configuration Configuration) UPS5000-E-50K-HABBS...
  • Page 2 UPS5000-E-125K-HASBS(02311FTE-002) (1) Power input (2) ATS status indicator (3) Lighting (4) ATS handle circuit breaker installation slot (5) Air conditioner power (6) IT load circuit distribution circuit breaker breaker (7) UPS input (8) UPS maintenance circuit breaker bypass circuit breaker (9) Control (10) Bypass module module...
  • Page 3: Installing The Ups

    2. Use insulated tools during installation. 3. Only engineers certified by Huawei or its agents are allowed to install, commission, and maintain the UPS. Otherwise, personal injury or equipment damage may occur, and the UPS faults caused are beyond the warranty scope of Huawei.
  • Page 4 (Optional) Installing the Tail Frame 1. Secure the tail frame fittings to the tail frame. 2. Secure the tail frame upper sealing plate to the tail frame. There are two upper sealing plates, and the one used in this step has a gap. 3.
  • Page 5: Connecting Cables

    1. Open the front and rear doors. Wrench the 2. Remove the cabinet connecting kits from the anchor bolts using an wrench to adjust the rack. cabinet height. Use a level to level the cabinet. 3. Secure the connecting kits in the connection positions on the front door using screws.
  • Page 6 Recommended Cross-Sectional UPS5000-E- UPS5000-E- UPS5000-E- UPS5000-E- Areas for Power Cables 125K (ATS) 125K (MCCB) 50K (ATS) 50K (MCCB) Input I current (A) Recommended circuit Three-pole, Three-pole, Three-pole, Three-pole, Breaker 400 A 400 A 250 A 250 A Input I Recommended 4 x 185 4 x 185 4 x 95...
  • Page 7 • Please refer to the user manual for details about cable requirements. • The cabling route is for reference only. Connect cables based on site requirements. 1. Remove the insulation protective panel from 2. Connect a ground cable to the UPS cabinet. the rear of the cabinet and remove covers from the top as required.
  • Page 8 02311FTC-004 and 02311FTE-004 ATS input 4. Connect battery cables, AC output power cables, fire protection cables and generator Start/Stop cables. Neutral cables PE cables Battery cables IT and air conditioner output power cables Lighting cables Fire Protection and Generator Start/Stop Cables (ATS input cabinet)
  • Page 9: Verifying The Installation

    5. Connect a communications cable between the FE port on the UPS monitoring interface card and any PoE port on the ETH gateway. ETH gateway Port Description Bolt Specifications Bolt Length Torque AC input 45 mm 46 N· m Battery input 30 mm 26 N·...
  • Page 10 Before System Power-On Perform system commissioning and power-on strictly according to the system manual and ATS instructions. For any changes in operations and parameters, consult Huawei engineers. Otherwise, system commissioning or power-on may fail, or even the cabinet is damaged.
  • Page 11 (1) OTM_C8D (2) Motor/Manual controller (8D selection lever controller for short) (3) Motor operator (4) Handle locking latch (5) Manual handle (6) Handle buckle (7) Position for (8) Transfer switch auxiliary contacts (10) Alarm ID (9) Operator description 1. Switch on the power switch for the ATS electric operation mechanism (Q1 and Q2 in the lower left side at the rear of the cabinet) to power the ATS electric operation mechanism.
  • Page 12 5. Modify configurations of the 8D controller. 1. You are not allowed to modify the ATS configurations if not authorized by Huawei engineers. 2. When the controller is in button mode, do not simultaneously press and hold down the I, II, and O buttons on the controller panel.
  • Page 13: Powering On And Starting The Ups

    Before System Power-On". Switch on the MCCB. Switch on the UPS input circuit breaker QF1. The UPS works in normal mode and starts initialization. The LCD displays the Huawei logo and an initialization progress bar. Starting the Inverter • Single/Parallel, Output frequency, Battery capacity, and Number of cells must be correctly set.
  • Page 14 Number of Number of Battery Battery Batteries Strings Connected Number of Battery Capacity Specifications Connected in in Parallel to the Cells Series 100 Ah + 100 Ah = 200 100 Ah/12 V 32 x 6 = 192 100 Ah + 100 Ah = 200 100 Ah/2 V 192 x 1 = 192 100 Ah + 100 Ah + 100...
  • Page 15 Start the inverter on the app. • The Service Expert app can be downloaded from Huawei app store and can run on Android. • The port number is 443 by default and can be modified. If the UPS is managed using the app,...
  • Page 16 Download the mobile phone app (Service Expert). Use the app to start the inverter No, start the online? inverter offline Insert the WiFi module into the USB port on On the MDU, choose System Info > the MDU. Set System Info > Settings > Maintenance >...
  • Page 17: Shutting Down The Ups

    Powering On Loads 1. Check that the UPS has transferred to normal mode and that the Bypass mode alarm has disappeared. Use a multimeter to check that the valid three-phase output voltage is 220 V AC, 230 V AC, or 240 V AC and the frequency is 50 Hz or 60 Hz. 2.
  • Page 18 Common Alarms and Troubleshooting Measures Alarm Possible Cause Troubleshooting Measures Mains ph. The mains input phase sequence Verify that the mains input phase sequence is reversed is reversed. correct using a phase sequence meter. Bypass ph. The bypass input phase Verify that the bypass input phase sequence is reversed sequence is reversed.
  • Page 19 Scan here for technical support (carrier): Huawei App Store Scan here for more documents: Support-E Support WeChat You can also log in to Huawei technical support website: http://support.huawei.com/enterprise http://support.huawei.com Huawei Technologies Co., Ltd. Huawei Industrial Base, Bantian, Longgang Shenzhen 518129 People's Republic of China...