HERMetic Sampler GTN Chem Portable Closed Sampling Device With closed liquid transfer Note: before using the instrument please read this book. This document is subject to changes without notice. Check updates on www.tanksystem.com or contact us at [email protected] 50447/SGTN/1306 HERMetic Sampler GTN Chem...
1. Table of contents TABLE OF CONTENTS RECOMMENDATION FOR SAFE USE GENERAL INFORMATION 3.1 S HIPMENT NOTE 3.2 I NITIAL INSPECTION 3.3 D OCUMENTATION DISCREPANCIES 3.4 W ARRANTY 3.5 C ERTIFICATION 3.6 S PARE PARTS 3.7 S ERVICE AND EPAIR WORLDWIDE SERVICE STATIONS NETWORK DESCRIPTION 5.1 G...
2. Recommendation for safe use This Operation and Service Manual is a guide in order to help the user to operate the instrument to safely and correctly. Nevertheless the maker disclaims all responsibility and liability for damage resulting from the use of the equipment regardless of the cause of the damage.
3. General information When returned to Enraf Tanksystem SA or Shipment note agreed Service Stations equipment must be contamination-free. If it is determined that the Purchasers The following parts should be included in the equipment is contaminated, it will be shipment: returned Purchaser...
: +41-26-91 91 500 Telefax : +41-26-91 91 505 Web site www.tanksystem.com E-mail [email protected] Spare parts Substitution of components may impact safety. Use only original spare parts. When ordering spares identify the spare part by TS number and description. Refer to section “Drawings”.
Page 6
Service Request Customer's address: ..........................................................................................................Telephone: ....................Telex: ....................... Fax: ......................Type of unit or part: ........................................Serial number : ..................Short description of defective unit or part: ..............................................................................Do you want a quotation before repair is started:..yes / no..... Repaired unit has to be returned to the following address: ........................
5. Description 5.1 General The HERMetic Samplers are designed for closed sampling of liquids or chemicals, which present a Fire-, Health- or Air pollution Hazard. The gas tight construction of these units avoids a pressure release from the tank and exposure to fumes during operation. The equipment is designed and certified for use in potentially explosive atmospheres area.
5.3 Sampling principle 5.3.1 Connection and grounding system All HERMetic products are easy to connect. Indeed, all HERMetic devices are equipped with a quick coupler for connection on a HERMetic ball valve. Place the unit on the appropriate valve and activate the locking system. Depending on the locking system, either rotate the collar and actuate the lever or pull on the sleeve.
5.3.2 Sampling method The sample is taken by a vertical move of the bottle inside the fluid. The bottle is linked with a graduated tape. A reading window allows to monitor the bottle location. For complete explanation of sampling procedures, please refer to §6 “Operation”. Important note: to avoid contamination of the sample taken by the sampler itself, check and clean the unit and the bottle prior to use.
6. Operation 6.1 Checking before use Before using the sampler : Check the good state of the device. Check the cleanliness of the unit (sampler and bottle) to prevent any contamination of the sample. Inspect the bottle tape end for breaks, kinks and wear. If there is some damage, replace the tape before use.
Operating the ZONE SAMPLING BOTTLE DESCRIPTION 30293 10374 Zone bottle 0,43 l. FFKM assy 1. Install the HERMetic Sampler GTN Chem with the sampling bottle on top of the HERMetic 2” ball valve by means of the quick connect coupling. In case the air which is inside the HERMetic Sampler housing can contaminate the sample it is recommended to purge the Sampler after it has been installed on the HERMetic 2”...
Operating the BOTTOM SAMPLING BOTTLE DESCRIPTION 20247 20132 Bottom bottle 0.40 l FFKM assy 1. Install the HERMetic Sampler GTN Chem with the sampling bottle on top of the HERMetic 2” ball valve by means of the quick connect coupling. In case the air which is inside the HERMetic Sampler housing can contaminate the sample it is recommended to purge the Sampler after it has been installed on the HERMetic 2”...
Operating the SPOT SAMPLING BOTTLE DESCRIPTION 20253 20134 Spot bottle 0.40 l. FFKM 1. Install the HERMetic Sampler GTN Chem with the sampling bottle on top of the HERMetic 2” ball valve by means of the quick connect coupling. In case the air which is inside the HERMetic Sampler housing can contaminate the sample it is recommended to purge the Sampler after it has been installed on the HERMetic 2”...
Operating the RUNNING SAMPLING BOTTLE DESCRIPTION 20216 20117 Running bottle 0.40 l. FFKM The calibration plug on top of the running bottle has to be adjusted according to the liquid to be sampled. The plug is properly set up when the transferred quantity of liquid falls between 70 and 85% of the capacity of the sampling bottle, i.e.
7. Care & Maintenance 7.1 Safety warning As this equipment has been certified as non-electrical equipment for potentially explosive atmospheres. Specific precautions have to be taken regarding maintenance of the device. The user can exchange parts and modules if following points are observed : 1.
7.3 Sampler cleaning To clean HERMetic Sampler GTN Chem, carter winder can be easily removed as well and sampling bottle detached from tape. It is required to fit the cleanliness level with the sample goals. Where appropriate, dismantle the sampler and clean the parts with an appropriate cleaner to prevent any contamination of the sample by the sampler itself.
Transportation of HERMetic devices For transportation of the device, always stretch out the tape to avoid any move of the the bottle inside its storage tube. 7.10 Recycling of HERMetic devices Equipment does not contain any dangerous materials inside which can harm the environment and people health during normal use or disposal.
8. Specifications General Specifications Tape length up to 35 m/115 ft Tape graduation Metric/English 1 mm / 1/16” Tape resolution ±6.3mm/35 m (±1/4”/115 ft approx.) Tape accuracy Maximum tank pressure Atmospheric pressure ±0.3 bar (4.4 psi) Liquid density up to 8kg/dm³ Ambient temperature range -20°C to 80 °C (-4°F to 176°F) Maximum liquid temperature...
9. Drawings & Declaration of Conformity These documents are enclosed in following pages. Sampler O = Option, according to specific order. DESCRIPTION 20334 10087 Sampler GTN Chem assembly * * * * * * * * * * Sampler GTN Chem 35 m assembly 20281 10316 Carter winder FFKM assy...