Honeywell HERMetic GTN Chem Operation And Service Manual

Honeywell HERMetic GTN Chem Operation And Service Manual

Portable closed sampling device with closed liquid transfer

Quick Links

Operation and Service Manual
for HERMetic Sampler GTN Chem
Portable Closed Sampling Device
With closed liquid transfer
Note: before using the instrument
please read this book.
This document is subject to changes without notice.
Check updates on
www.tanksystem.com
or contact us at
50447/SGTN/1306
1
HERMetic Sampler GTN Chem
Table of Contents
loading

Summary of Contents for Honeywell HERMetic GTN Chem

  • Page 1 HERMetic Sampler GTN Chem Portable Closed Sampling Device With closed liquid transfer Note: before using the instrument please read this book. This document is subject to changes without notice. Check updates on www.tanksystem.com or contact us at [email protected] 50447/SGTN/1306 HERMetic Sampler GTN Chem...
  • Page 2: Table Of Contents

    1. Table of contents TABLE OF CONTENTS RECOMMENDATION FOR SAFE USE GENERAL INFORMATION 3.1 S HIPMENT NOTE 3.2 I NITIAL INSPECTION 3.3 D OCUMENTATION DISCREPANCIES 3.4 W ARRANTY 3.5 C ERTIFICATION 3.6 S PARE PARTS 3.7 S ERVICE AND EPAIR WORLDWIDE SERVICE STATIONS NETWORK DESCRIPTION 5.1 G...
  • Page 3: Recommendation For Safe Use

    2. Recommendation for safe use This Operation and Service Manual is a guide in order to help the user to operate the instrument to safely and correctly. Nevertheless the maker disclaims all responsibility and liability for damage resulting from the use of the equipment regardless of the cause of the damage.
  • Page 4: General Information

    3. General information When returned to Enraf Tanksystem SA or Shipment note agreed Service Stations equipment must be contamination-free. If it is determined that the Purchasers The following parts should be included in the equipment is contaminated, it will be shipment: returned Purchaser...
  • Page 5: Certification

    : +41-26-91 91 500 Telefax : +41-26-91 91 505 Web site www.tanksystem.com E-mail [email protected] Spare parts Substitution of components may impact safety. Use only original spare parts. When ordering spares identify the spare part by TS number and description. Refer to section “Drawings”.
  • Page 6 Service Request Customer's address: ..........................................................................................................Telephone: ....................Telex: ....................... Fax: ......................Type of unit or part: ........................................Serial number : ..................Short description of defective unit or part: ..............................................................................Do you want a quotation before repair is started:..yes / no..... Repaired unit has to be returned to the following address: ........................
  • Page 7: Worldwide Service Stations Network

    TELEPHONE/FAX/E-MAIL SWITZERLAND ENRAF TANKSYSTEM SA Tel : +41-26-91 91 500 2, rue de l'Industrie Fax : +41-26-91 91 505 CH-1630 BULLE [email protected] CANADA PYLON ATLANTIC Tel : +1-902-4683344 A Div. Of Pylon Electronics Inc. Fax : +1-902-4681203 31 Trider Crescent., [email protected]...
  • Page 8 12 Clipstone Brook Industrial Estate Fax :+44-1525-852345 Cherrycourt Way [email protected] LEIGHTON BUZZARD, BEDS, LU7 4TX U.S.A / TEXAS HONEYWELL HERMETIC Tel : +1-281-930 1777 4522 Center Street Fax : +1-281-930 1222 DEER PARK, TX 77536 Toll free call in the USA: 1-800-900 1778 [email protected]...
  • Page 9: Description

    5. Description 5.1 General The HERMetic Samplers are designed for closed sampling of liquids or chemicals, which present a Fire-, Health- or Air pollution Hazard. The gas tight construction of these units avoids a pressure release from the tank and exposure to fumes during operation. The equipment is designed and certified for use in potentially explosive atmospheres area.
  • Page 10: Sampling Principle

    5.3 Sampling principle 5.3.1 Connection and grounding system All HERMetic products are easy to connect. Indeed, all HERMetic devices are equipped with a quick coupler for connection on a HERMetic ball valve. Place the unit on the appropriate valve and activate the locking system. Depending on the locking system, either rotate the collar and actuate the lever or pull on the sleeve.
  • Page 11: Sampling Method

    5.3.2 Sampling method The sample is taken by a vertical move of the bottle inside the fluid. The bottle is linked with a graduated tape. A reading window allows to monitor the bottle location. For complete explanation of sampling procedures, please refer to §6 “Operation”. Important note: to avoid contamination of the sample taken by the sampler itself, check and clean the unit and the bottle prior to use.
  • Page 12: Operation

    6. Operation 6.1 Checking before use Before using the sampler :  Check the good state of the device.  Check the cleanliness of the unit (sampler and bottle) to prevent any contamination of the sample.  Inspect the bottle tape end for breaks, kinks and wear. If there is some damage, replace the tape before use.
  • Page 13: Operating The Zone Sampling Bottle

    Operating the ZONE SAMPLING BOTTLE DESCRIPTION 30293 10374 Zone bottle 0,43 l. FFKM assy 1. Install the HERMetic Sampler GTN Chem with the sampling bottle on top of the HERMetic 2” ball valve by means of the quick connect coupling. In case the air which is inside the HERMetic Sampler housing can contaminate the sample it is recommended to purge the Sampler after it has been installed on the HERMetic 2”...
  • Page 14: Operating The Bottom Sampling Bottle

    Operating the BOTTOM SAMPLING BOTTLE DESCRIPTION 20247 20132 Bottom bottle 0.40 l FFKM assy 1. Install the HERMetic Sampler GTN Chem with the sampling bottle on top of the HERMetic 2” ball valve by means of the quick connect coupling. In case the air which is inside the HERMetic Sampler housing can contaminate the sample it is recommended to purge the Sampler after it has been installed on the HERMetic 2”...
  • Page 15: Operating The Spot Sampling Bottle

    Operating the SPOT SAMPLING BOTTLE DESCRIPTION 20253 20134 Spot bottle 0.40 l. FFKM 1. Install the HERMetic Sampler GTN Chem with the sampling bottle on top of the HERMetic 2” ball valve by means of the quick connect coupling. In case the air which is inside the HERMetic Sampler housing can contaminate the sample it is recommended to purge the Sampler after it has been installed on the HERMetic 2”...
  • Page 16: Operating The Running Sampling Bottle

    Operating the RUNNING SAMPLING BOTTLE DESCRIPTION 20216 20117 Running bottle 0.40 l. FFKM The calibration plug on top of the running bottle has to be adjusted according to the liquid to be sampled. The plug is properly set up when the transferred quantity of liquid falls between 70 and 85% of the capacity of the sampling bottle, i.e.
  • Page 17: Care & Maintenance

    7. Care & Maintenance 7.1 Safety warning As this equipment has been certified as non-electrical equipment for potentially explosive atmospheres. Specific precautions have to be taken regarding maintenance of the device. The user can exchange parts and modules if following points are observed : 1.
  • Page 18: Sampler Cleaning

    7.3 Sampler cleaning To clean HERMetic Sampler GTN Chem, carter winder can be easily removed as well and sampling bottle detached from tape. It is required to fit the cleanliness level with the sample goals. Where appropriate, dismantle the sampler and clean the parts with an appropriate cleaner to prevent any contamination of the sample by the sampler itself.
  • Page 19: Transportation Of Hermetic Devices

    Transportation of HERMetic devices For transportation of the device, always stretch out the tape to avoid any move of the the bottle inside its storage tube. 7.10 Recycling of HERMetic devices Equipment does not contain any dangerous materials inside which can harm the environment and people health during normal use or disposal.
  • Page 20: Specifications

    8. Specifications General Specifications Tape length up to 35 m/115 ft Tape graduation Metric/English 1 mm / 1/16” Tape resolution ±6.3mm/35 m (±1/4”/115 ft approx.) Tape accuracy Maximum tank pressure Atmospheric pressure ±0.3 bar (4.4 psi) Liquid density up to 8kg/dm³ Ambient temperature range -20°C to 80 °C (-4°F to 176°F) Maximum liquid temperature...
  • Page 21: Drawings & Declaration Of Conformity

    9. Drawings & Declaration of Conformity These documents are enclosed in following pages. Sampler O = Option, according to specific order. DESCRIPTION 20334 10087 Sampler GTN Chem assembly * * * * * * * * * * Sampler GTN Chem 35 m assembly 20281 10316 Carter winder FFKM assy...