Fujitsu ASTG18KMTC Service Instruction page 37

Split type room air conditioner wall mounted type inverter
Hide thumbs Also See for ASTG18KMTC:
Table of Contents
Trouble shooting 2
INDOOR UNIT Error Method:
Wired remote controller
communication error
Detective Actuators:
Indoor unit Controller PCB
Wired remote control
Forecast of Cause:
1. Terminal connection abnormal
Check Point 1 : Check the connection of terminal
After turning off the power, check & correct the followings.
Check the connection of terminal between remote control and Indoor unit,
and check if there is a disconnection of the cable.
OK
OK
Check Point 2 : Check Remote control and Controller PCB
Check Voltage at CNC01 (terminal 1-3) of UTY-TWBXF1(Communication kit).
(Power supply to Remote control)
>> If it is DC13V, Remote control is failure. (Controller PCB is normal)
>> If it is DC 0V, Controller PCB is failure. (Check Remote control once again) >> Replace Controller PCB
Upon correcting the removed connector or mis-wiring, reset the power.
Indicate or Display:
Outdoor Unit : No indication
Indoor Unit
: Operation lamp: 1 time Flash, Timer lamp: 2 times Flash
Economy lamp: Continuous flash.
ERROR CODE : [E : 12]
Detective details:
When the indoor unit cannot receive the signal from Wired remote control
more than 1minute during normal operation.
2. Wired remote control failure
02-12
3. Controller PCB failure
>> Replace Remote control
Table of Contents
loading

This manual is also suitable for:

Astg22kmtcAstg24kmtcAotg18kmtcAotg22kmtcAotg24kmtc

Table of Contents