  • Page 1 Service Manual Air Curtain Model NO. FY-3009U1 FY-3012U1 FY-3015U1 Basic series FY-4009U1 FY-4012U1 FY-4015U1 FY-3009G1 FY-3012G1 FY-3015G1 Remote control series FY-4009G1 FY-4012G1 FY-4015G1 FY-3009D1 FY-3012D1 FY-3015D1 Sensor series FY-4009D1 FY-4012D1 FY-4015D1 Panasonic Ecology Systems Guangdong Co.Ltd Beijing Branch...
  • Page 20 Exploded drawing for basic series Exploded drawing for packing of basic series...
  • Page 21 Part list for basic series FY-3009U1 FY-3012U1 FY-3015U1 FY-4009U1 FY-4012U1 FY-4015U1 FRONT ACU10001 ACU10003 ACU10001 ACU10003 ACU10002 ACU10002 PANEL IMPELLE ACU10004 ACU10006 ACU10004 ACU10006 ACU10005 ACU10005 IMPELLE ACU10007 ACU10008 ACU10009 ACU10007 ACU10008 ACU10009 LOUVER ASSY ACU10010 ACU10011 ACU10012 ACU10010 ACU10011...
  • Page 22 Part list for basic series FY-3009U1 FY-3012U1 FY-3015U1 FY-4009U1 FY-4012U1 FY-4015U1 REAR GUIDER ACU10034 ACU10036 ACU10034 ACU10036 ACU10035 ACU10035 MOTOR SUPPOR ACU10037 ACU10038 ACU10038 ACU10038 ACU10038 ACU10037 PACKAG ACU10039 ACU10041 ACU10042 ACU10043 ACU10044 ACU10040 BOTTOM ACU10045 ACU10046 ACU10046 ACU10045 ACU10046...
  • Page 23: Cleaning The Impeller

    Name plate is affixed on right side of unit, indicating model No. and product No.. Safety precaution • Make sure to disconnect the power source before maintenance. • Don’t impair the related part in maintenance. •Initial operation after maintenance shall be done while few people around because large amount of dust could be caused .
  • Page 24 Safety precaution • make sure to disconnect the power source before maintenance. • don’t damage the related part in maintenance • wear the protection equipment in maintenance Replace the front cover pull out the cap as shown in figure above before releasing the you can replace the remove the front cover by screw in middle , and this screw...
  • Page 25: Replace The Impeller

    you can replace the release the screw as open the cover of push- push-button switch. indicated above button switch. Caution • don’t impair the cord while replacing the push-button switch • firmly connect the connector after replacement • pay attention to not get push-button switch stuck in switch board (confirm the push-button switch is in bounce ) Replace the impeller
  • Page 26 loosen the jbckscrew used for fixing replace the impeller after removing impeller with cross screwdriver only loosen Caution for replacing the impeller LEFT RIGHT • replace the right impeller with same method • there’s indication of position on the side of impeller (refer to right figure),don’t reverse the position.
  • Page 27 then you can replace the shaft after remove the metal plate removing. Replace the capacitor then you can replace the capacitor after release the screws. removing. Replace the motor release the screws used for fixing the remove the metal part, there’s a risk of motor as indicated above dropping...
  • Page 28 release the screws fixed on side plate near remove the side plate to motor release the screws used for fixing the move to left side and remove the motor motor bracket. assembly Caution for replacing the motor • don’t impair the cord during replacement •...