Beko BEKOMAT 8 Installation And Operating Manual

Beko BEKOMAT 8 Installation And Operating Manual

Hide thumbs Also See for BEKOMAT 8:

Quick Links

EN - English
Installation and operating manual
Condensate drain
BEKOMAT
BEKOMAT
8
®
9
®
Table of Contents
loading

Summary of Contents for Beko BEKOMAT 8

  • Page 1 EN - English Installation and operating manual Condensate drain BEKOMAT ® BEKOMAT ®...
  • Page 2 Installation and operating manual BEKOMAT ®...
  • Page 3: Table Of Contents

    Installation and operating manual Contents 1. Safety information ............................4 1.1. Pictograms and symbols .......................... 4 1.1.1. In this documentation ................................4 1.1.2. On the device ..................................4 1.2. Signal words according to ISO 3864 and ANSI Z.535 ................4 1.3. General safety instructions ........................5 1.4.
  • Page 4: Safety Information

    Installation and operating manual 1. Safety information 1.1. Pictograms and symbols 1.1.1. In this documentation General instructions Observe installation and operating instructions General hazard symbol (danger, warning, caution) General hazard symbol (danger, warning, caution) relating to mains voltage and powered machine parts 1.1.2.
  • Page 5: General Safety Instructions

    Installation and operating manual 1.3. General safety instructions DANGER Insufficient qualification Improper handling and operation of the device might result in serious or even fatal injury, and/or serious damage to property. • All tasks described in this installation and operating manual must be performed by specialist technical personnel who meet the criteria outlined below: •...
  • Page 6 Installation and operating manual Warranty and liability for defects NOTICE Claims made with reference to warranty and liability for defects shall only be deemed valid, if the following instructions are strictly adhered to: • Do not make any modifications to the device! •...
  • Page 7: Transport And Storage

    Despite our best efforts regarding packaging, etc., the device might be damaged during transport. Upon delivery, please remove all packaging material and inspect the device for visible damage. If you detect such damage, immediately notify the carrier company and BEKO TECHNOLOGIES GMBH or one of its agents. CAUTION...
  • Page 8: Intended Use

    Installation and operating manual 1.5. Intended use The BEKOMAT is an electronically level-controlled condensate drain for compressed air systems. It is able to drain condensate ® from the plant components at operating pressure and with virtually no compressed air loss. •...
  • Page 9: Product Information

    The type plate is attached to the device housing. It contains all key data of the BEKOMAT®. Please have these details to hand when contacting the manufacturer or supplier. Hersteller: BEKO TECHNOLOGIES GmbH Baujahr: 2016 zul. Betriebsdruck: 0,5 ... 10 bar zul.
  • Page 10: Product Overview And Description

    Installation and operating manual 2.2. Product overview and description Condensate inlet Manual drain Venting line Valve LED Control elements / electrical control Alarm LED Solenoid valve Power LED Condensate discharge/solenoid valve Test button Type plate NOTICE No permanent drainage Do not use the test button for permanent drainage! BEKOMAT ®...
  • Page 11: Function

    Installation and operating manual 2.3. Function Discharge The condensate enters the container (1) through the condensate inlet. The container can be filled to the limit, as the pressure is equalised through the venting line (2). The capacitive dual sensor (3) constantly monitors the filling level in the container.
  • Page 12: Dimensions

    Installation and operating manual 2.4. Dimensions 2.4.1. BEKOMAT ® G1-i 68,3 (2.7) Flansch/flange G¾-i C 50 x 60,3 DIN 1092-1 30° G¾-i 237(9.3) 150 (5.9) Ø 11 486 (19.1) 2.4.2. BEKOMAT ® G2-i 68,3 (2.7) Flansch/flange G¾-i C 50 x 60,3 DIN 1092-1 25°...
  • Page 13: Technical Data

    Installation and operating manual 2.5. Technical data General data BM 08 BM 09 Min./max. storage/transport temperature +1 ... +60 °C Min./max. medium/ambient temperature +1 ... +60 °C Min./max. operating pressure 0.5 ... 10 bar 0.5 ... 4 bar Condensate inlet C50 x 60.3 DIN 1092-1 flange Condensate discharge Venting connection...
  • Page 14: Installation

    Installation and operating manual 3. Installation 3.1. Warning DANGER Insufficient qualification, explosion Improper handling and operation of the device can result in serious or even fatal injury, and/or damage to property. • All tasks described in this installation and operating manual must be performed by specialist technical personnel who meet the criteria outlined below: •...
  • Page 15: Installation

    Installation and operating manual 3.2. Installation The diagrams below show examples of BEKOMAT 8/9 installation options. ® NOTICE Installation instructions • Install a separate BEKOMAT at each point where condensate might be produced. ® • Do not use cone-shaped fittings. •...
  • Page 16: Electrical Installation

    Installation and operating manual 4. Electrical installation 4.1. Installation instructions DANGER Insufficient qualification Improper handling and operation of the device might result in serious or even fatal injury, and/or serious damage to property. • All tasks described in this installation and operating manual must be performed by specialist technical personnel who meet the criteria outlined below: •...
  • Page 17 Installation and operating manual Netzteil Oscillator Power supply Netzanschluss Power Gehäuse Housing Sensor Sensor-Kreis Zeitauswertung Ventilsteuerung Magnetventil Sensor loop Time analysis Valve control Solenoid valve Alarmkontakt Alarm contact Alarmkontrolle Alarm monitoring Connecting power cable: • Push the cable through the cable screw and connect it to terminals L1, N, PE Alarm signal line: The device is equipped with a floating alarm relay (changeover) for the transfer of alarm signals in the event of a fault: •...
  • Page 18: Operation

    Installation and operating manual 5. Operation The operating state of the BEKOMAT is indicated as follows. ® Normal status: Normal operation: • Green "POWER" LED is lit: Power OK, BEKOMAT in operation ® Error status: • Yellow "VALVE" LED is lit: Max. filling level reached ...
  • Page 19: Function Test

    Installation and operating manual 5.1. Function test Testing normal function To test the solenoid valve, press the test button briefly (for approx. 2 seconds).  Red "ALARM" LED flashes, yellow "VALVE" led is lit  Valve to condensate discharge is opened Testing alarm function To test the solenoid valve alarm function, close the condensate inlet and press and hold the test button for approx.
  • Page 20: Maintenance And Servicing

    Improper handling and operation of the device might result in serious or even fatal injury, and/or serious damage to property. • All maintenance tasks must be performed by service personnel of BEKO TECHNOLOGIES GmbH or an authorised BEKO partner. Recommended interval: 1x per year...
  • Page 21: Cleaning

    Installation and operating manual 6.2. Cleaning To clean the BEKOMAT , use a damp (but not wet) cotton cloth or disposable tissue and a mild conventional detergent. ® Spray a little detergent onto the clean cotton cloth or tissue and carefully wipe the component. Dry the device with a clean cloth or let it dry at room temperature.
  • Page 22: Spare Parts

    Installation and operating manual 6.3. Spare parts BEKOMAT ® 230 VAC 2000450 Wearing parts kit Solenoid valve, complete BEKOMAT ® Hose connector 230 VAC 4005382 Hose piece Other voltage ratings: on request Gasket kit 8x gaskets for sensor BEKOMAT ® 1x gasket for manual drain 2000683 BEKOMAT...
  • Page 23: Troubleshooting And Repair

    If your device has come into contact with a hazardous substance, also enclose a declaration of decontamination. The relevant templates can be downloaded from our homepage at www.beko-technologies.com. If your device arrives at our service workshop without a declaration of decontamination, and should our personnel be concerned about any media with which it might have come into contact, we will contact you.
  • Page 24: Declaration Of Conformity

    Installation and operating manual 8. Declaration of Conformity BEKOMAT ®...
  • Page 25 Voltage options: 24VAC/ 100VAC/ 110VAC 200VAC, 230VAC: Pressure options: 0,5 - 10 bar (g) (only BEKOMAT 8) 0,5 - 4 bar (g) (only BEKOMAT 9) Product description and function: Condensate drain for the electronically level-controlled discharge of condensate in the compressed-air system.
  • Page 26 Installation and operating manual BEKOMAT ®...
  • Page 27 Installation and operating manual BEKOMAT ®...
  • Page 28 Italy 日本 / Japan Poland BEKO TECHNOLOGIES S.r.l BEKO TECHNOLOGIES K.K BEKO TECHNOLOGIES Sp. z o.o. Via Peano 86/88 KEIHIN THINK Building 8 Floor Ul. Pańska 73 I - 10040 Leinì (TO) 1-1 Minamiwatarida-machi PL - 00-834 Warszawa Phone +39 011 4500 576...