Sony BDX-M1000 Installation Manual

Mpeg multiplexer unit

Quick Links

MPEG MULTIPLEXER UNIT
BDX-M1000
INSTALLATION MANUAL
1st Edition (Revised 1)
Serial No. 10001 and Higher: BDX-M1000
Table of Contents
loading

Summary of Contents for Sony BDX-M1000

  • Page 1 MPEG MULTIPLEXER UNIT BDX-M1000 INSTALLATION MANUAL 1st Edition (Revised 1) Serial No. 10001 and Higher: BDX-M1000...
  • Page 2 Pour toute réparation faire appel à une personne compétente uniquement. For the U.S.A. Attention-when the product is installed in Rack: (For BDX-M1000) 1. Prevention against overloading of branch circuit When this product is installed in a rack and is supplied power from an outlet on the rack, please make sure that the rack does not overload the supply circuit.
  • Page 3: Table Of Contents

    2. Service Overview 2-1. Cleaning of Air Filter .................. 2-1 2-2. Description of Internal Indicators ............... 2-2 2-2-1. IPM-81 Board ................2-2 2-2-2. OPM-25 Board ................2-3 2-2-3. SY-244 Board ................2-4 Appendix. Setting of Output Data Rate 1 (E) BDX-M1000...
  • Page 5: Manual Structure

    Manual Structure Purpose of this manual This manual is the installation manual of the BDX-M1000 MPEG Multiplexer Unit . This manual is intended for use by trained system and service engineers, and describes information regarding installation. Related manuals Besides this installation manual, the following manuals are available for the BDX- M1000.
  • Page 7: Installation

    BDX-M1000 is installed. 2 Plug holder (Black) 2-990-242-01 Plug holder is included in DK-2401 (UK). The rear side of the BDX-M1000 should be at least 20 cm (8 inches) away from walls for ventilation and maintenance. AC inlet Do not block the ventilation holes.
  • Page 8: External Dimensions

    The BDX-M1000 can be mounted in a 19-inch standard rack. . When the BDX-M1000 or the peripheral equipment is mounted in a 19-inch standard rack, it is recom- mended to install a ventilation fan to prevent a temperature rise in the rack.
  • Page 9 : The BDX-M1000 comes with the eight screws. The two screws of them are spare. 4. Attach the inner rails to the BDX-M1000 using the six screws (B4x8) supplied with the BDX-M1000. Be sure to use the RMM-30 Rack Mount Rail.
  • Page 10 Stopper 581 (Maximum traveling distance) Inner rail . Be sure to mount the BDX-M1000 in the rack with two or more persons. Distance to the center of the slide rail Trying to handle this job by one-person could occur to...
  • Page 11: Matching Connectors And Cables

    When connecting cables to various connectors on the rear panel at the time of installing or servicing, connect the following connectors/cables or their equivalents. BDX-M1000 Matching Connector/Cable Panel Indication Connector/Cable SONY Part No. BIT STREAM INPUT BNC 75 Z, male 1-569-370-12 5C-2V cable (*1) REF.VIDEO INPUT...
  • Page 12: Input And Output Signal Of Connector

    XDATA 5B Data 4B XDATA 6B Data 3B XDATA 7B (MSB) Data 2B SOP B (=Start of packet B) Data 1B N.C. Data 0B PBYTE CLK (B) DVALID B (=Data valid B) PSYNC B (=Packet sync B) 1-6 (E) BDX-M1000...
  • Page 13: Switch Setting Of Connector Panel

    When the loop-through output is not used, set the 75 Z TALLY control unit termination switch to ON. (external) This switch is factory-set to OFF. BDX-M1000 4 10BASE-T (8-pin Modular jack) – External view – Pin No. Signal TXD +...
  • Page 14: Settings Of Internal Switches

    . The addresses on the board are shown by ( ) marks. . For the switches described “Unassigned”, do not change the factory setting. S101 (A-2): Reset switch Do not press this switch under normal conditions. 1-8 (E) BDX-M1000...
  • Page 15: Opm-25 Board

    Factory setting: All switches are set to 0. lever position.) S905 S904 S902 S901 Set the PID (=Packet ID) of output packet in hexadecimal. S905 is MSB side, and S901 is LSB side. (Example) To set the PID at “1A7C”: S905=1, S904=A, S902=7, S901=C 1-9 (E) BDX-M1000...
  • Page 16 ComStream Corporation, set both of set by S1100 and S500 to S504 is over-written. two parameters ML and TT of CM3000 at “0”.) . When the BDX-M1000 is not connected to the S1101(A-3): modulator, do not set this switch at “0”. If this Factory setting: All switch levers set to ON.
  • Page 17 S800 to S802 (A-2 to 4): Factory use Do not press these switches under normal conditions. S803 (A-1): Reset switch Do not press this switch under normal conditions. If this switch is pressed, all setting data of BDX-M1000 will be reset. S502 S700...
  • Page 19: Service Overview

    When washing the filter, be sure to dry it well. . Filter (3U) : 2-139-072-03 6. After cleaning, fasten the filter to the tapes. If the BDX-M1000 is kept on operating with too dusty of the filter, the temperature inside the unit getting rise. This may cause a fire.
  • Page 20: Description Of Internal Indicators

    D204 : Channel Error indicator When S201-5 is set to OFF : Blinks when some error occurs at the input circuit. When S201-5 is set to ON : Lights up when the channel overflowed at input buffer exists. D205 : Unassigned 2-2 (E) BDX-M1000...
  • Page 21: Opm-25 Board

    D1101 (A-3) (green) : Modulator Clock indicator Lights up when a clock supplied from modulator connect- ed to the BDX-M1000 is detected. D1102 (A-3) (green) : REF. LOCK indicator Lights up when internal clock synchronizes to REF.VIDEO input signal.
  • Page 22: Sy-244 Board

    Lights up when data is transmitted to D312 (J-4) (red) : Factory use Ethernet port#5. D104 (yellow) : LAN#5 Received Lights up when data is received from Ethernet port#5. D105, D106 (green) : Factory use D107, D108 (red) : Factory use 2-4 (E) BDX-M1000...
  • Page 23 Only D706 lights up under normal conditions. D801 to D803 (A-8) (orange) : Factory use Only D801 lights up under normal conditions. D804 to D806 (A-8) (orange) : Factory use Only D804 lights up under normal conditions. 2-5 (E) BDX-M1000...
  • Page 25 15.30 11.80 15.40 11.90 15.50 12.00 15.60 12.10 15.70 12.20 15.80 12.30 15.90 12.40 16.00 12.50 16.10 12.60 16.20 12.70 16.30 12.80 16.40 12.90 16.50 13.00 16.60 13.10 16.70 13.20 16.80 13.30 16.90 13.40 17.00 13.50 17.10 A-1 (E) BDX-M1000...
  • Page 26 23.70 19.60 23.80 19.70 23.90 19.80 24.00 19.90 24.10 20.00 24.20 20.10 24.30 20.20 24.40 20.30 24.50 20.40 24.60 20.50 24.70 20.60 24.80 20.70 24.90 20.80 25.00 20.90 25.10 21.00 25.20 21.10 25.30 21.20 25.40 21.30 25.50 A-2 (E) BDX-M1000...
  • Page 27 32.10 28.00 32.20 28.10 32.30 28.20 32.40 28.30 32.50 28.40 32.60 28.50 32.70 28.60 32.80 28.70 32.90 28.80 33.00 28.90 33.10 29.00 33.20 29.10 33.30 29.20 33.40 29.30 33.50 29.40 33.60 29.50 33.70 29.60 33.80 29.70 33.90 A-3 (E) BDX-M1000...
  • Page 28 40.50 36.40 40.60 36.50 40.70 36.60 40.80 36.70 40.90 36.80 41.00 36.90 41.10 37.00 41.20 37.10 41.30 37.20 41.40 37.30 41.50 37.40 41.60 37.50 41.70 37.60 41.80 37.70 41.90 37.80 42.00 37.90 42.10 38.00 42.20 38.10 42.30 A-4 (E) BDX-M1000...
  • Page 29 48.90 44.80 49.00 44.90 49.10 45.00 49.20 45.10 49.30 45.20 49.40 45.30 49.50 45.40 49.60 45.50 49.70 45.60 49.80 45.70 49.90 45.80 50.00 45.90 50.50 46.00 51.00 46.10 51.50 46.20 52.00 46.30 52.50 46.40 53.00 46.50 53.50 A-5 (E) BDX-M1000...
  • Page 30 86.50 66.00 87.00 66.50 87.50 67.00 88.00 67.50 88.50 68.00 89.00 68.50 89.50 69.00 90.00 69.50 90.50 70.00 91.00 70.50 91.50 71.00 92.00 71.50 92.50 72.00 93.00 72.50 93.50 73.00 94.00 73.50 94.50 74.00 95.00 74.50 95.50 A-6 (E) BDX-M1000...
  • Page 31 128.50 108.00 129.00 108.50 129.50 109.00 130.00 109.50 130.50 110.00 131.00 110.50 131.50 111.00 132.00 111.50 132.50 112.00 133.00 112.50 133.50 113.00 134.00 113.50 134.50 114.00 135.00 114.50 135.50 115.00 136.00 115.50 136.50 116.00 137.00 116.50 137.50 A-7 (E) BDX-M1000...
  • Page 32 170.50 150.00 171.00 150.50 171.50 151.00 172.00 151.50 172.50 152.00 173.00 152.50 173.50 153.00 174.00 153.50 174.50 154.00 175.00 154.50 175.50 155.00 176.00 155.50 176.50 156.00 177.00 156.50 177.50 157.00 178.00 157.50 178.50 158.00 179.00 158.50 179.50 A-8 (E) BDX-M1000...
  • Page 33 A. Setting of Output Data Rate Output data rate S1100 S500 S501 S502 S503 S504 (Mbps) 180.00 180.50 181.00 181.50 182.00 182.50 183.00 183.50 184.00 184.50 185.00 185.50 186.00 186.50 187.00 187.50 188.00 188.50 189.00 189.50 190.00 A-9 (E) BDX-M1000...
  • Page 35 The material contained in this manual consists of information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation.
  • Page 36 Printed in Japan Sony Corporation BDX-M1000 (SY) J, E 1999. 8 11 Broadcasting & Professional Systems Company 3-194-483-02 ©1997...

Table of Contents