Overview
Safety instructions
Installing and connecting the
device
Software and commissioning
Expand device
Maintaining and repairing the
device
Certificates and approvals
Dimension drawings
Technical specifications
Hardware descriptions
Technical support
Markings and symbols
List of abbreviations
1
2
3
4
5
6
7
8
9
10
A
B
C
Table of Contents
loading

Summary of Contents for Siemens SIMATIC IOT2050

  • Page 1 SIMATIC IOT2050 Preface Overview Safety instructions Installing and connecting the device SIMATIC IOT SIMATIC IOT2050 Software and commissioning Expand device Operating Instructions Maintaining and repairing the device Certificates and approvals Dimension drawings Technical specifications Hardware descriptions Technical support Markings and symbols...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    The device documentation comprises: ● Product information, for example, "Important notes on your device" ● Quick Install Guide SIMATIC IOT2050 ● SIMATIC IOT2050 operating instructions in German, English and Chinese Conventions The following generic terms are used in this documentation:...
  • Page 4 Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
  • Page 5: Table Of Contents

    Preface ..............................3 Overview..............................7 Product description ........................7 Structure of the devices ......................9 1.2.1 SIMATIC IOT2050 ........................9 Accessories ..........................10 Safety instructions ..........................11 General safety instructions ..................... 11 Data protection ........................14 Notes on use ........................... 14 Installing and connecting the device ......................
  • Page 6 Markings and symbols .......................... 63 Overview ..........................63 Safety ............................. 63 Operator controls ........................63 Certificates, approvals and markings ..................64 Interfaces ..........................65 List of abbreviations ..........................66 Glossary ............................... 68 Index ..............................70 SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 7: Overview

    Features ● High degree of ruggedness ● Compact design ● External RS232/RS422/RS485, Ethernet, DP and USB interfaces ● Internal interfaces for Arduino Shield and Mini PCIe card ● Freely programmable interfaces ● Maintenance-free SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 8 6ES7647-0BA00-0YA2 6ES7647-0BA00-1YA2 Processor TI SOC AM6528 GP Dual Core TI SOC AM6548 HS Quad Core with High Security possibility 1 GB RAM (DDR4) 2 GB RAM (DDR4) eMMC 16 G Battery-buffered real-time clock SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 9: Structure Of The Devices

    Overview 1.2 Structure of the devices Structure of the devices 1.2.1 SIMATIC IOT2050 The following figures show the configuration and interfaces of the SIMATIC IOT2050. ① Ethernet interfaces 100/1000 Mbps ⑦ LED display, see section "Motherboard (Page 52)" ② ⑧...
  • Page 10: Accessories

    DisplayPort line 3 m long 6AV7860-0DH30-0AA0 5 m long 6AV7860-0DH50-0AA0 Arduino Shield SIMATIC IOT2000 Input/Output Module, 6ES7647-0KA01-0AA2 5 x DI, 2 x AI, 2 x DO SIMATIC IOT2000 Input Module 6ES7647-0KA02-0AA2 Sink/Source, 10 x DI SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 11: Safety Instructions

    WARNING Risk of fire through expansion cards Expansion cards generate additional heat. The device may overheat and cause a fire. Note the following: • Observe the safety and installation instructions for the expansion cards. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 12 LEDs on a plug-in card in the device visible. • Cables are routed from the inside out of the device or from the outside into the device, for example, to connect sensors or displays. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 13 When you touch electrostatic sensitive components, you can destroy them through voltages that are far below the human perception threshold. If you work with components that can be destroyed by electrostatic discharge, observe the ESD Guideline. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 14: Data Protection

    2.2 Data protection Data protection Siemens observes the data protection guidelines, especially the requirements regarding data minimization (privacy by design). This means the following for this SIMATIC product: The product does not process / save any personal information, but only technical functional data (e.g.
  • Page 15: Installing And Connecting The Device

    4. Check the contents of the packaging and any accessories you may have ordered for completeness and damage. – Device – DC connecting terminal, already plugged into the device. – One mounting accessory kit including: 1 x Rail clamp, 2 x mounting brackets and screws. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 16 6. Keep the enclosed documentation in a safe place. You need the documentation when you commission the device for the first time. 7. Write down the identification data of the device. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 17: Identification Data Of The Device

    The device can be mounted horizontally or vertically on a DIN rail or to a wall. Vertical mounting position, preferred Horizontal mounting position Consider the permitted temperature range for operation that depends on the mounting position in accordance with the "Technical specifications" section. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 18: Mounting The Device

    ● Install all the expansions in the device before mounting the device on a DIN rail or a wall, see section "Expand device (Page 29)". ● Siemens recommends you use 0.6 Nm tightening torque to install the mounting clamps and brackets.
  • Page 19: Mounting On Din Rails

    Mounting on DIN rails 3.2.2.1 Secure the mounting clips Requirement ● The DIN rail is installed at the installation site (35 mm standard profile). ● Mounting bracket and mounting clamps ● Two screws ● T8 screwdriver SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 20 2. Fasten the rail clamp with the two supplied screws. 3. Lay the brackets on the rear of the device. Align the bracket edge with the device edge. 4. Fasten the brackets with the supplied screws. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 21: Mounting On Din Rails

    Vertical Horizontal Removing 1. Push down the device until it is released by the rail clamp. 2. Swing the device out of the standard profile rail. 3. Lift the device up and off. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 22: Wall Mounting

    1. Lay the mounting brackets on the rear of the device. 2. Fasten the brackets with supplied screws. 3. Mark the bore holes, drill the required holes in the wall and fasten the device to the wall using two screws. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 23: Horizontal Wall Mounting

    1. Lay the mounting brackets on the rear of the device. 2. Fasten the brackets with supplied screws. 3. Mark the bore holes, drill the required holes in the wall and fasten the device to the wall using two screws. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 24: Connecting The Device

    • Only connect I/O devices which are approved for industrial applications in accordance with EN 61000-6-2 and IEC 61000-6-2. • I/O devices that are not hotplug-capable may only be connected after the device has been disconnected from the power supply. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 25: Connecting The Function Earth

    • Never operate the device without function earth. • If a device is defective, remove it from operation without delay and label it accordingly. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 26: Connecting The Power Supply

    (Page 48)". If there are voltage peaks on power supply lines, use a protective device in the form of a varistor (MOV) UMOV = U-rated x 1.2 (BLITZDUCTOR BVT AVD 24 (918 422) or compatible). SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 27 1. Switch off the power supply. 2. Connect the lines to the connecting terminal with a torque of 0.56 Nm (5lb- in). 3. Connect the connecting terminal to the connection for the power supply. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 28: Software And Commissioning

    Operating system and software for the SIMATIC IOT devices are freely programmable and are downloaded from the Micro SD/eMMC card when the device is booted. For SIMATIC IOT2050 6ES7647-0BA00-1YA2: The device starts with "Secure Boot", which means the SD card with the customer-specific image must be signed accordingly.
  • Page 29: Expand Device

    2. Push the Micro SD card/Nano SIM card correctly into the supporting frame. The contacts of the Micro SD card/Nano SIM card must point in the direction of the motherboard. 3. Push the card cover back. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 30: Install Arduino Shield

    The temperature in the housing of the device can be up to 30 °C above the maximum permissible ambient temperature of the device. Make sure that the maximum permissible ambient temperature of the Arduino shield is specified accordingly. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 31 You can use the four boreholes in the motherboard to additionally fasten the Arduino shield on the motherboard. The boreholes are shown in the figure above. Only use fixing elements made from plastic, not metallic or conductive materials. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 32: Install Mini Pcie Card

    The following example describes the installation of a Mini PCIe card, including mounting of the antenna jacks. If you install a different Mini PCIe card, the work steps 4, 5 and 7 are not required. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 33 7. Connect the cables of mini PCIe installation accessory to the Mini PCIe card. 8. Get the cable of mini PCIe installation accessory out of the housing through the whole drilled in step 4. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 34 Carefully insert the COM interface into the top housing. 2. Insert the two plastic clips of top housing into the clip holes on heatsink. 3. Press the top housing to fix the clips. Then install power plug and screws for COM interface. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 35: Installing Half-Size Mini Pcie Card

    2. Install the standoff to the place as shown in the picture. 3. Insert the half-size Mini PCIe card in the Mini PCIe interface on the motherboard as illustrated. 4. Fix the mini PCIe card with one M2 screw. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 36 5. Connect the cables of mini PCIe installation accessory to the Mini PCIe card. 6. Get the cable of mini PCIe installation accessory out of the housing. Then install the top housing (Page 32). SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 37: Maintaining And Repairing The Device

    This can result in malfunctions and damage to the machine or plant. Make sure you take precautionary measures even when you open the device, for example, when opening device doors, device covers or the housing cover. For more information, refer to the chapter "ESD Guideline" SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 38: Replacing The Backup Battery (For 6Es7647-0Ba00-1Ya2 Only)

    • Do not throw lithium batteries into fire, do not solder on the cell body, do not recharge, do not open, do not short-circuit, do not reverse polarity, do not heat above 100°C and protect from direct sunlight, moisture and condensation. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 39 • Label the battery container "Used batteries and rechargeable batteries". Requirement ● The device is disconnected from the power supply. ● A replacement battery with the article number A5E34345932 is available. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 40 Remove the top housing of the enclosure. Remove the marked screws on the motherboard. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 41: Recycling And Disposal

    Contact a certified disposal service company for electronic scrap for environmentally sound recycling and disposal of your old devices, and dispose of the device according to the relevant regulations in your country. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 42: Certificates And Approvals

    The associated declaration of conformity is available on the Internet at the following address: AUTOHOTSPOT. ISO 9001 certificate The Siemens quality management system for all production processes (development, production and sales) meets the requirements of GB/T 19001-2008/ISO 9001:2015, ISO 14001:2015 + Cor. 1:2009 and BS OHSAS 18001:2007.
  • Page 43 ● Declaration of conformity according to Technical Regulations of the Customs Union (TR Korea Certification This product satisfies the requirement of the Korean Certification (KC Mark). 이 기기는 업무용(A급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며 가정 외의 지역에서 사용하는 것을 목적으로 합니다. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 44: Directives And Declarations

    The following abbreviations are commonly used for electrostatic sensitive devices: ● ESD – Electrostatic sensitive device ● ESD – Electrostatic Sensitive Device as a common international designation Electrostatic sensitive devices can be labeled with an appropriate symbol. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 45 These values conform to the specifications of IEC 61000-4-2. ① Synthetic materials ② Wool ③ Antistatic materials such as wood or concrete SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 46 This way, the discharge energy does not reach and damage the sensitive components. – Discharge your body electrostatically before you take a measurement at a module. Do so by touching grounded metallic parts. Always use grounded measuring instruments. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 47: Dimension Drawings

    Dimension drawings The following figures show the dimension drawings of the type IOT2050. All dimensions in mm. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 48: Technical Specifications

    61000-4-6 If there are voltage peaks on power supply lines, use a protective device in the form of a varistor (MOV) UMOV = U-rated x 1.2 (BLITZDUCTOR BVT AVD 24 (918 422) or compatible). SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 49 1 x mini PCIe for PCIe cards 30 x 50.59 mm or 30 x 26.8 mm via adapter Interfaces All devices of the type SIMATIC IOT2050 USB Type A, X60 2 x USB 2.0 host, high current, max. 2.5 W/500 mA...
  • Page 50: Ambient Conditions

    5 to 8.4 Hz: Deflection 3.5 mm • • 8.4 Hz to 500 Hz: Acceleration 9.8 m/s • Impact resistance, tested in accordance with IEC 60068-2-27 150 m/s , 11 ms Operation • 250 m/s , 6 ms Storage/transport • SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 51: Power Demand Of The Components

    24 W Typical power consumption Power consumption (at a rated voltage of 24 V) Basic device 12 W Arduino shields See section "Power demand of the components (Page 51)" USB ports Expansion cards SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 52: Hardware Descriptions

    Hardware descriptions 10.1 Motherboard The following figures show the motherboard of the SIMATIC IOT2050. Pin 1 SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 53 Jumper defines VIN connection to the Arduino ply, 24 V DC) shield: Jumper on pins 1-2: VIN is connected to • the Arduino shield Jumper on pins 2-3: VIN is not connected • to the Arduino shield SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 54: External Interfaces

    Name of interface on the device: USB1 - X60 - USB2 -Pin Assignment +5 VDC, out (max. 500 mA) USB-DN USB-DP 10.2.3 Ethernet port RJ45 socket Name of interface on the device: P1 - X1 LAN - P2 SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 55: Serial Port

    RS 232 RS 422 RS 485 Assignment RS 232 Short description Meaning Data carrier detect (I) Received data (I) Transmitted data (O) Data terminal ready (O) Ground Data set ready (I) Request to send (O) SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 56: Internal Interfaces

    The tables below show the pin assignment of the interfaces of the Arduino shield, depending on the operating mode. The position of the interfaces and Pin 1 of the respective interface is available in section "Motherboard (Page 52)". SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 57 Hardware descriptions 10.3 Internal interfaces Operating mode DIGITAL ANALOG POWER SERIAL MOSI MISO Operating mode DIGITAL ANALOG POWER SERIAL UART_R UART_Tx UART_C UART_R Operating mode DIGITAL ANALOG POWER SERIAL SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 58: Uart Debug

    Hardware descriptions 10.3 Internal interfaces Operating mode DIGITAL ANALOG POWER SERIAL IOREF RESET 3,3 V X15 (ICSP) Operating mode DIGITAL ANALOG POWER SERIAL MISO MOSI RESET 10.3.2 UART Debug Assignment RTS_N n. c. CTS_N SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 59: Mini Pcie Interface

    COEX2 1.5 V COEX1 WAKE# 3.3 V 10.3.4 Micro SD interface Abbreviation Function Dat2 Data line bit 2 Dat3 Card Detect / data line bit 3 Command Line Voltage supply 2.7–3.6 V Clock input SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 60: Displayport 1.1A

    AUX CH_P Auxiliary channel+ Bidirectional Ground AUX CH_N Auxiliary channel- Bidirectional Hot plug Hot Plug Detect output Return Return for power Connected to ground DP_PWR Power for connector (3.3 V 500 mA) power out SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 61: Technical Support

    You can find additional information and support for the products described on the Internet at the following addresses: ● SIMATIC IOT2000 (www.siemens.com/iot2000) ● Technical support (https://support.industry.siemens.com) ● After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) ● SIMATIC Documentation Collection (http://www.siemens.com/simatic-tech-doku-portal) ● Your local representative (https://www.automation.siemens.com/aspa_app) ● Training center (http://sitrain.automation.siemens.com/sitrainworld/?AppLang=en) ●...
  • Page 62: Troubleshooting

    User button can't work when User button and Arduino inter- Avoid using user button and Arduino shield reset pin is work- face reset pin can't work at Arduino interface reset pin at ing. same time. the same time. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 63: Markings And Symbols

    Opening for Kensington lock opening Attention ESD (Electrostatic sensitive Warning of hot surface device) Operator controls Symbol Meaning Symbol Meaning On/off switch, without electrical isola- Eject CD/DVD tion On/off switch, without electrical isola- tion SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 64: Certificates, Approvals And Markings

    Marking of Federal Communications Commission for the USA EFUP (Environment Friendly Use Approved for Korea Period) marking for China Test mark of the Underwriters La- Disposal information, observe the boratories local regulations. Approval for India SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 65: Interfaces

    LAN interface, not approved for con- Line Out necting WAN or telephone Serial port Microphone input USB port Universal Audio Jack USB 2.0 high-speed port Headphone output USB 3.0 super-speed port USB 3.1 SuperSpeedPlus interface SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 66: List Of Abbreviations

    Machine-readable product desig- nation Personal computer PCIe Peripheral Component Intercon- High-speed serial, differential full-duplex PtP nect express interface with high data rate. Programming device Ring Input Incoming call Request to send Request to send SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 67 SELV Safety Extra Low Voltage Safety extra low voltage UEFI Unified Extensible Firmware In- terface Underwriters Laboratories Inc. US organization for testing and certification ac- cording to national or binational standards. Universal Serial Bus SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 68: Glossary

    Embedded Linux Linux for industrial, embedded systems (see "Debian"). ESD Guideline Guideline for using electrostatic sensitive components. Ethernet Local network (bus structure) for text and data communication with a transfer rate of 100/1000 Mbps. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 69 Generic term which describes all functions for controlling and monitoring user program execution, distribution of system resources to the user programs and the operating mode in cooperation with the hardware (for example, Windows 7 Ultimate). Reset Hardware reset: Reset/restart of the PC using a button/switch. SIMATIC IOT2050 Operating Instructions, 03/2020, A5E39456816-AA...
  • Page 70: Index

    Clearance, 18 Installing Components sensitive to electrostatic charge, 44 Arduino shield, 30 Condensation, 16 Backup battery, 39 Configuration Mini PCIe card, 32 SIMATIC IOT2050, 9 Interface Connecting DisplayPort, 60 function earth, 25 Interfaces, 49 Peripherals, 24 Power supply, 26 Connecting the function earth, 26...
  • Page 71 New Zealand, 43 Noise emission, 48 Package contents, 15 Checking, 15 Packaging, 15 Checking, 15 Removing, 15 Ports SIMATIC IOT2050, 9 Power supply Connecting, 26 DC power supply, 51 Processor, 49 PROFINET, 51 Protection class, 48 Protective measure Static electricity, 46...