Siemens SIMATIC S7-1500 Manual

Power supply module, 6es7505-0rb00-0ab0
Hide thumbs Also See for SIMATIC S7-1500:
Power supply module
PS 60W 24/48/60VDC HF (6ES7505-0RB00-0AB0)
SIMATIC
S7-1500/ET 200MP
Power supply module
PS 60W 24/48/60VDC HF
(6ES7505-0RB00-0AB0)
Manual
01/2019
A5E39450002-AB
Preface
Documentation guide
Product overview
Wiring
Parameters
Interrupts, diagnostic alarms,
error and status alarms
Technical specifications
Dimensional drawing
Parameter data record
1
2
3
4
5
6
A
B
Table of Contents
loading

Summary of Contents for Siemens SIMATIC S7-1500

  • Page 1 Power supply module Preface PS 60W 24/48/60VDC HF (6ES7505-0RB00-0AB0) Documentation guide SIMATIC Product overview Wiring S7-1500/ET 200MP Power supply module Parameters PS 60W 24/48/60VDC HF (6ES7505-0RB00-0AB0) Interrupts, diagnostic alarms, error and status alarms Manual Technical specifications Dimensional drawing Parameter data record 01/2019 A5E39450002-AB...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks.
  • Page 4 We are liable for the product described, including the open-source software contained in it, pursuant to the conditions applicable to the product. Siemens accepts no liability for the use of the open source software over and above the intended program sequence, or for any faults caused by modifications to the software.
  • Page 5: Table Of Contents

    Table of contents Preface ..............................3 Documentation guide ..........................6 Product overview ..........................10 Properties ..........................10 Operating and display elements ..................... 12 Wiring ..............................13 Wiring the power supply module ..................... 13 Parameters ............................15 Parameters ..........................15 Interrupts, diagnostic alarms, error and status alarms ................16 Status and error displays ......................
  • Page 6: Documentation Guide

    Documentation guide The documentation for the SIMATIC S7-1500 automation system, the CPU 1516pro-2 PN based on SIMATIC S7-1500 and the SIMATIC ET 200MP distributed I/O system is arranged into three areas. This arrangement enables you to access the specific content you require.
  • Page 7 You can download the product information free of charge from the Internet (https://support.industry.siemens.com/cs/us/en/view/68052815). Manual Collection S7-1500/ET 200MP The Manual Collection contains the complete documentation on the SIMATIC S7-1500 automation system and the ET 200MP distributed I/O system gathered together in one file. You can find the Manual Collection on the Internet (https://support.industry.siemens.com/cs/ww/en/view/86140384).
  • Page 8 ● Manuals, characteristics, operating manuals, certificates ● Product master data You can find "mySupport" - CAx data on the Internet (http://support.industry.siemens.com/my/ww/en/CAxOnline). Application examples The application examples support you with various tools and examples for solving your automation tasks. Solutions are shown in interplay with multiple components in the system - separated from the focus on individual products.
  • Page 9 You can find the SIMATIC Automation Tool on the Internet (https://support.industry.siemens.com/cs/ww/en/view/98161300). PRONETA With SIEMENS PRONETA (PROFINET network analysis), you analyze the PROFINET network during commissioning. PRONETA features two core functions: ● The topology overview independently scans PROFINET and all connected components.
  • Page 10: Product Overview

    Product overview Properties Order number 6ES7505-0RB00-0AB0 View of the module Figure 2-1 View of the PS 60W 24/48/60VDC HF module Power supply module PS 60W 24/48/60VDC HF (6ES7505-0RB00-0AB0) Manual, 01/2019, A5E39450002-AB...
  • Page 11 Product overview 2.1 Properties Properties The PS 60W 24/48/60VDC HF power supply module supports the use of additional modules. Advantage over the "standard" power supply module: To save a higher volume of data retentively in case of power failure, the PS 60W 24/48/60VDC HF supplies power to the CPU.
  • Page 12: Operating And Display Elements

    Product overview 2.2 Operating and display elements Operating and display elements The following figure shows the control and connection elements of the PS 60W 24/48/60VDC HF behind the front panel as well as the power connector. ① LED displays indicating the current operating state and diagnostic status of the PS ②...
  • Page 13: Wiring

    Wiring Wiring the power supply module Mains connection WARNING Installation instructions Risk of death or serious injury. Observe the general installation instructions applicable in your country when wiring the power supply module. Fuse the power cables according to their conductor cross-section. The following applies to mains connection of the power supply module using the power connector: ●...
  • Page 14 S7-1500/ET 200MP Automation System (https://support.industry.siemens.com/cs/ww/en/view/59191792). Siemens recommends the use of devices from the SITOP family of products for applications with load power supplies. Wiring information is available in the documentation for the load power supply.
  • Page 15: Parameters

    Parameters Parameters Parameters of the PS 60W 24/48/60VDC HF The PS 60W 24/48/60VDC HF is usually already integrated in the hardware catalog of STEP 7 (TIA Portal). In this case, STEP 7 (TIA Portal) checks the configured properties for plausibility during configuration. However, you can also assign parameters to the module by means of a GSD file and the configuration software of any provider.
  • Page 16: Interrupts, Diagnostic Alarms, Error And Status Alarms

    Interrupts, diagnostic alarms, error and status alarms Status and error displays Introduction Diagnostics by means of LEDs is a basic tool for troubleshooting. Usually, you can pinpoint the source of error more precisely by analyzing the module status information in STEP 7, or in the diagnostic buffer of the CPU.
  • Page 17 Interrupts, diagnostic alarms, error and status alarms 5.1 Status and error displays Meaning of the LED displays The following table explains the meaning of the status and error displays. You can find remedial measures for diagnostic alarms in chapter Diagnostic alarms (Page 18). Table 5- 1 Status and error displays RUN/ERROR/MAINT Meaning...
  • Page 18: Diagnostic Alarms

    Interrupts, diagnostic alarms, error and status alarms 5.2 Diagnostic alarms Diagnostic alarms Diagnostic alarms The following table shows the meaning of the diagnostic alarms and possible remedial measures for the respective cause. One of the following "LED images" indicates directly on the PS that a diagnostic alarm was triggered.
  • Page 19: Interrupts

    Reactions to a diagnostic interrupt You can find the CPU reaction to a diagnostic interrupt in the function manual System diagnostics (http://support.automation.siemens.com/WW/view/en/59192926). Detailed information on the error event is available in the diagnostic interrupt OB by executing the "RALRM" instruction (read additional interrupt information) and in the STEP 7 Online Help.
  • Page 20: Technical Specifications

    Technical specifications Technical specifications of the PS 60W 24/48/60VDC HF Article number 6ES7505-0RB00-0AB0 General information Product type designation PS 60 W 24/48/60 V DC HF HW functional status Firmware version V1.0.0 Engineering with V14 SP1 STEP 7 TIA Portal configurable/integrated as of version •...
  • Page 21 Technical specifications Article number 6ES7505-0RB00-0AB0 Degree and class of protection Degree of protection acc. to EN 60529 IP20 Equipment protection class I, with protective conductor Dimensions Width 105 mm Height 147 mm Depth 129 mm Weights Weight, approx. 865 g Power supply module PS 60W 24/48/60VDC HF (6ES7505-0RB00-0AB0) Manual, 01/2019, A5E39450002-AB...
  • Page 22: Dimensional Drawing

    Dimensional drawing Dimensional drawing of PS 60W 24/48/60VDC HF This appendix includes the dimensional drawing of the power supply module that is installed on a mounting rail with shielding bracket. Take the dimensions into account for installation in cabinets, control rooms, etc. The following figure shows the front view and the side view of the module Figure A-1 Dimensional drawing of the PS 60W 24/48/60VDC HF module...
  • Page 23 Dimensional drawing The following figure shows the side view of the module with open front panel. Figure A-2 Dimensional drawing of the PS 60W 24/48/60VDC HF module Power supply module PS 60W 24/48/60VDC HF (6ES7505-0RB00-0AB0) Manual, 01/2019, A5E39450002-AB...
  • Page 24: Parameter Data Record

    Parameter data record Parameter assignment in the user program You have the option to re-parameterize the power supply module in RUN mode of CPU. Changing parameters in RUN mode The parameters of the power supply module are in data record 0. Using the instruction WRREC the adjustable parameters can be transferred to the power supply module.
  • Page 25 Parameter data record Data record structure The following figure shows the structure of the data record 0. ● A fixed bit pattern is entered in byte 0. It indicates the version of the data record structure. Each time a data record is written, the module checks the written data and accepts only data records with major version 1.

Table of Contents