Quick Links

Dell Networking S5000
Getting Started Guide
Regulatory Model: S5000
Table of Contents
loading

Summary of Contents for Dell S5000

  • Page 1 Dell Networking S5000 Getting Started Guide Regulatory Model: S5000...
  • Page 2: Notes, Cautions, And Warnings

    CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2013 Dell Inc. Trademarks used in this text: Dell , the Dell logo, Dell Boomi , Dell Precision , OptiPlex...
  • Page 3: Product Description

    The S5000 is purpose-built to provide architectural flexibility for unified and virtualized environments. It is a 10G ToR solution that enables converged local area networks (LAN) and storage area networks (SAN) in the same box. The S5000 delivers Fibre Channel over Ethernet (FCoE) and Fibre Channel (FC) capability in a one rack unit (RU) ToR switch form factor.
  • Page 4 Identify slots 0, 1, 2, and 3 on the Utility panel, refer to Figure 3. You can insert Power supply units (PSUs) only in slots 0 and 3. You can insert the Fan modules in any of the slots. Figure 1. S5000 I/O and Utility Panels 1. I/O panel...
  • Page 5: Hardware Installation Overview

    Install the SFP+ and QSFP+ optics. Supply power and power up the system. Hardware Overview This section contains information about device characteristics and modular hardware configurations for the S5000. The S5000 has the following physical dimensions: • Height: 1.71 inches (43.5 mm) •...
  • Page 6: Utility Panel

    3. Slot 2 (for Fan Module 1) Power Supplies The S5000 supports two hot-swappable PSUs. NOTE: The PSUs must be installed at the customer site. The S5000 has SKUs that support the following configurations: • AC PSU with fan airflow from I/O to Utility •...
  • Page 7: Port Numbering Convention

    The S5000 supports two fan trays with airflow directions from I/O to Utility or Utility to I/O. Do not mix I/O to Utility and Utility to I/O airflows in a single S5000 chassis. All fans and PSUs in a configuration must be in the same airflow direction.
  • Page 8 The following table lists the LED definitions for the S5000 system. Figure 5. System LEDs (Utility Panel) (AC Power Supplies installed) 1. Locator beacon LED 5. Seven–segment display to identify Stack ID 2. Alarm LED 6. PSU status LED 3. System status LED 7.
  • Page 9 Label LED Color/Display Description • Green solid • Normal operation • Green blinking • System is booting • Amber solid • System in card problem state • Green solid • Switch in Stacking Master Master LED mode OR Switch in •...
  • Page 10 Label LED Color/Display Description • Blue • Port beacon/locator Port link/activity LED • • No link or interface disabled • Green solid • Link present and interface enabled (Ethernet module) • Green blinking • Port has activity Module locator beacon LED •...
  • Page 11: Installation

    Figure 8. QSFP+ Port LEDs 1. Port link/activity LED Table 5. 40GbE Port/Module LEDs Label LED Color/Display Description Port link/activity LED • • No link or interface disabled • Green solid • Link present and interface enabled • Green blinking •...
  • Page 12: Attaching The Mounting Brackets

    NOTE: Always handle the system and its components with care. Avoid dropping the S5000 chassis or its field replaceable units. NOTE: For proper ventilation, position the S5000 chassis in an equipment rack (or cabinet) with a minimum of 5 inches (12.7 cm) of clearance around exhaust vents. The acceptable ambient temperature ranges are listed in the Environmental Parameters section.
  • Page 13: Rack Mounting Safety Considerations

    NOTE: The illustrations in this document are not intended to represent a specific switch. Installing the S5000 Chassis into a 4-Post Rack or Cabinet NOTE: Dell Networking recommends that one person hold the S5000 chassis in place while a second person attaches the brackets to the posts.
  • Page 14: Rack Grounding

    WARNING: Electrostatic discharge (ESD) damage can occur if components are mishandled. Always wear an ESD- preventive wrist or heel ground strap when handling the S5000 and its components. NOTE: For the Ethernet module, the part name and port number are inscribed on the handle, as shown in the...
  • Page 15: Installing An Ethernet Module

    NOTE: A blue color release latch indicates that the Ethernet module does not support hot swapping during switch operations. Instead, you must power down the switch before removing and replacing an Ethernet module. A red color release latch indicates that the Ethernet module supports hot swapping during switch operations. Figure 11.
  • Page 16: Important Points To Remember For Installing A Fibre Channel Module

    • The S5000 does not support the hot swapping of a Fibre Channel pluggable module during switch operations. Instead, you must power down the switch before removing and replacing a Fibre Channel module. WARNING: Electrostatic discharge (ESD) damage can occur if components are mishandled. Always wear an ESD-...
  • Page 17: Installing A Fibre Channel Module

    NOTE: The part name and port number of a Fibre Channel module are inscribed on the handle as shown below. Figure 13. Part name and Port number on the Fibre Channel Module Handle 1. Part Name 2. Port Number Installing a Fibre Channel Module Use the grab handle on the Fibre Channel module to slide it into the switch module slot.
  • Page 18: Important Points To Remember For Installing An Ac Power Supply

    The S5000 supports AC and DC power supplies with two air-flow directions (I/O to Utility and Utility to I/O). The S5000 does not support mixing PSU types, that is, you cannot replace an AC PSU with a DC PSU and an AC-R PSU with a DC-R PSU.
  • Page 19: Installing An Ac Power Supply

    (I/O to Utility or Utility to I/O). The power supplies and fans must have the same color strap. If you mismatch the airflows, the following error message appears and the system shuts down: 00:02:19: %S5000:0 %CHMGR-2-PSU_TYPE_AIRFLOW_MISMATCH: Mismatching PSU airflow detected. Unit 0 shall get shutdown in next 60 seconds if mismatch not rectified.
  • Page 20: Assembling And Connecting The Safety Ground Wire For Dc Power Supply

    Damage due to servicing that Dell Networking did not authorize is not covered by your warranty. Strip the insulation from the end of the green/yellow wire, exposing approximately 4.5 mm (0.175 inch) of copper wire.
  • Page 21: Important Points To Remember For Installing A Dc Power Supply

    The S5000 supports AC and DC power supplies with two air-flow directions (I/O to Utility and Utility to I/O). The S5000 does not support mixing PSU types, that is, you cannot replace an AC PSU with a DC PSU and an AC-R PSU with a DC-R PSU.
  • Page 22: Installing A Dc Power Supply

    WARNING: Electrostatic discharge (ESD) damage can occur if components are mishandled. Always wear an ESD- preventive wrist or heel ground strap when handling the S5000 and its components. CAUTION: DO NOT mix airflow directions. The airflow directions are color coded. A red label indicates that hot air is expelled from the PSU and a blue label indicates that hot air is expelled from the I/O.
  • Page 23: Installing The Ferrite Bead For Dc Power And Return Cables

    WARNING: To protect the power supply from electrostatic discharge, you must cover the captive screws with the rubber cap before inserting the mating connector into the power supply. Rotate the rubber cap clockwise to fix it over the captive screws. Insert the mating connector into the power supply.
  • Page 24: Securing Power Cables

    Figure 20. Installing the Ferrite Bead for DC Power and Return Cables 1. Ferrite Bead 2. DC Power and Return Cables Leave approximately 4 to 5 inches of the DC power and return cables end protruding from the ferrite. Snap the ferrite bead shut. Securing Power Cables Bend the system power cables, as shown in the following illustration, and attach to the cable clasp.
  • Page 25: Important Points To Remember For Installing A Fan Module

    • For proper ventilation, position the S5000 in an equipment rack (or cabinet) with a minimum of 5 inches (12.7 cm) of clearance around the exhaust vents. When you install two S5000 systems near each other, position the two chassis at least 5 inches (12.7 cm) apart to permit proper airflow.
  • Page 26: Installing The Sfp+ And Qsfp+ Optics

    Splitting QSFP+ Ports to SFP+ Ports The S5000 supports splitting a single 40GbE QSFP+ port into four 10GbE SFP+ ports using one of the supported breakout cables. For a list of supported optics, refer to the S5000 data sheet: http://www.dell.com/us/enterprise/p/force10-s-series/pd.
  • Page 27: Supplying Power And Powering Up The System

    LED at the top of the PSU. Connect the plug to each AC power connector. Make sure that the power cord is secure. As soon as the cable is connected between the S5000 and the power source, the chassis is powered-up; there is no on/off switch.
  • Page 28: Performing The Initial Configuration

    NOTE: Before starting this procedure, be sure that you have a terminal emulation program already installed on your The DB9 RS-232/RJ-45 console port is labeled on the lower left-hand side of the S5000 as you face the Utility side of the chassis.
  • Page 29: Accessing The Rj-45 Console Port With A Db-9 Adapter

    (for example, a PC). The pin assignments between the console and a DTE terminal server are as follows: Table 6. Pin Assignments Between the Console and a DTE Terminal Server S5000 Console Port RJ-45 to RJ-45 RJ-45 to RJ-45...
  • Page 30: Enter The Initial Configuration Information

    Figure 24. USB-B Console Port Connector Power on the PC. Install the necessary USB device drivers (you will need an Internet connection). For assistance, contact Dell Networking Technical Support. Connect the USB-A end of cable into an available USB port on the PC.
  • Page 31: Configuring The Enable Password

    – 5 is for inputting a password that is already encrypted using an MD5 hash. Obtain the encrypted password from the configuration file of another Dell Networking system. Configuring a Host Name The host name appears in the prompt. The default host name is FTOS. Host names must start with a letter, end with a letter or digit, and must have characters, letters, digits, and hyphens in the string.
  • Page 32: Default Configuration

    Default Configuration A version of FTOS is preloaded onto the S5000; however, the system is not configured when you power up for the first time (except for the default host name, which is FTOS). You must configure the system using the CLI.
  • Page 33 – 7 is for inputting a password that is already encrypted using a Type 7 hash. Obtaining the encrypted password from the configuration of another Dell Networking system. Creating a Port-based VLAN The default virtual local area network (VLAN) (VLAN 1) is part of the system startup configuration and does not require configuration.
  • Page 34 Assigning Interfaces to a VLAN You can only assign interfaces in Layer 2 mode to a VLAN using the tagged and untagged commands. To place an interface in Layer 2 mode, use the switchport command. You can designate Layer 2 interfaces as tagged or untagged. When you place an interface in Layer 2 mode using the switchport command, the interface is automatically designated untagged and placed in the Default VLAN.
  • Page 35: Technical Specifications

    Connecting the S5000 to the Network After you have completed the hardware installation and software configuration for the S5000 system, you can connect to your company network by following your company’s cabling requirements. Figure 25. RJ-45 Network/Management Port Technical Specifications NOTE: Operate the product at an ambient temperature not higher than 40°C.
  • Page 36 Parameter Specifications Maximum thermal output 2388 BTU/hr Maximum Altitude No performance degradation to 6600 ft Shock Meets Bellcore Zone 4 earthquake requirements Table 9. Power Requirements Parameter Specifications AC Power supply 100 VAC ~ 240 VAC 50/60 Hz DC Power supply –48V ~ –60V VDC 7 A @ 100 VAC Maximum current draw per system...

Table of Contents