Mitsubishi Electric EHPT20 series Operation Manual

Cylinder unit and hydrobox
Hide thumbs Also See for EHPT20 series:

Quick Links

Cylinder Unit
eHSt20 series
eHPt20 series
oPeration ManUal
For safe and correct use, please read this operation manual thoroughly before operating the cylinder unit and
the hydrobox.
bedienUnGSanleitUnG
Lesen Sie sich zur sicheren und korrekten Verwendung diese Bedienungsanleitung bitte sorgfältig durch,
bevor Sie das Hydraulikmodul inkl. Speicher und die Hydrobox verwenden.
Mode d'eMPloi
Pour garantir une utilisation sûre et appropriée, lisez attentivement le présent mode d'emploi avant d'utiliser
l'ECODAN hydrobox duo et l'ECODAN hydrobox.
HandleidinG
Voor een veilig en juist gebruik moet u deze handleiding goed doorlezen alvorens de cilinder en hydrobox in
gebruik te nemen.
ManUal de inStrUCCioneS
Para un uso correcto y seguro del hydrobox duo y del Hydrobox, lea este manual de instrucciones antes de su
utilización.
ManUale di FUnZionaMento
Per un uso corretto e sicuro del dispositivo, leggere attentamente il presente manuale di funzionamento prima
di utilizzare l'hydrotank e l'hydrobox.
ManUal de FUnCionaMento
Para uma utilização segura e correcta, é favor ler cuidadosamente este manual de funcionamento antes de
trabalhar com o cilindro e permutador de calor.
brUGSvejledninG
Læs venligst denne brugsvejledning grundigt inden betjening af i tank modulet (unit) og hydroboksen.
användarManUal
För säker och korrekt användning, var god läs denna användarmanual noggrant innan du använder i cylindertanken
och hydroboxen.
brUkSanviSninG
Les denne bruksanvisningen nøye før du bruker sylinderenheten og hydroboksen for å sikre trygg og riktig
bruk.
käyttöoPaS
Turvallisen ja asianmukaisen käytön varmistamiseksi lue tämä käyttöopas huolellisesti ennen varaajayksikön
ja hydroboxin käyttöä.
Hydrobox
eHSC series
eHPx series
erSC series
For USer
FÜr nUtZer
PoUr leS UtiliSateUrS
voor de GebrUiker
Para el USUario
Per l'Utente
Para o UtiliZador
til brUGer
För användaren
For brUkeren
käyttäjälle
english (Gb)
deutsch (d)
Français (F)
nederlands (nl)
español (e)
italiano (i)
Português (P)
dansk (de)
Svenska (SW)
norsk (no)
Suomi (Fi)
Table of Contents
loading

Summary of Contents for Mitsubishi Electric EHPT20 series

  • Page 1 Cylinder Unit Hydrobox eHSt20 series eHSC series eHPt20 series eHPx series erSC series oPeration ManUal For USer english (Gb) For safe and correct use, please read this operation manual thoroughly before operating the cylinder unit and the hydrobox. bedienUnGSanleitUnG FÜr nUtZer deutsch (d) Lesen Sie sich zur sicheren und korrekten Verwendung diese Bedienungsanleitung bitte sorgfältig durch,...
  • Page 2: Customising Settings For Your Home

    The following is a guide to viewing the main settings. Should you require more information please
    contact your installer or local Mitsubishi Electric dealer. Cooling mode is available for ERS series only. However, Cooling mode is not avail- Letter...
  • Page 3: General Operation

    Customising Settings for Your Home General Operation In general operation the screen displayed on the main controller will be shown as in the figure on the right. This screen shows the target temperature, space heating mode, DHW mode (if DHW tank is present in system), any additional heat sources being used, holiday mode, and the date and time.
  • Page 4 Customising Settings for your Home For room sensor settings it is important to choose the correct room sensor de- pending on the heating mode the system will operate in. 1. From the Initial settings menu select Room sensor settings. 2.
  • Page 5: Domestic Hot Water (Dhw)/Legionella Prevention

    Customising Settings for your Home domestic Hot Water (dHW)/legionella Prevention The domestic hot water and legionella prevention menus control the operation of DHW tank heat ups. 1. Highlight the hot water icon and press CONFIRM. 2. Use button F to switch between Normal and ECO heating modes. 3.
  • Page 6 Customising Settings for Your Home Explanation of Legionella Prevention Mode operation DHW tank temp. Stop Stop • At the time entered by the installer ‘Start time’ flow of useful heat from the sys- Restart tem is diverted to heat the water in the DHW tank. Stop temp. • When the temperature of the stored water exceeds the ‘Hot Water temp.’ set by Legionella the installer (above 65°C) primary circuit water is no longer diverted to heat the hot water temp.
  • Page 7: Holiday Mode

    Customising Settings for Your Home Holiday Mode Holiday mode can be used to keep the system running at lower flow temperatures and thus reduced power usage whilst the property is unoccupied. Holiday mode can run either flow temp, room temp, heating, compensation curve heating and DHW all at reduced flow temperatures to save energy if the occupier is absent.
  • Page 8: Service Menu

    Customising Settings for your Home . In the preview menu screen press F4 button. Preview screen 2. First select the days of the week you wish to schedule. 3. Press F2/F3 buttons to move between days and F to check or uncheck the box.
  • Page 9: Service And Maintenance

    Service and Maintenance Troubleshooting The following table is to be used as a guide to possible problems. It is not exhaustive and all problems should be investigated by the installer or another competent person. Users should not attempt to repair the system themselves. At no time should the system be operating with the safety devices by-passed or plugged.