Page 1
Embedded Computing for Business-Critical Continuity RTM-ATCA-F120-OPT Installation and Use P/N: 6806800G29B January 2009...
Page 2
Emerson reserves the right to revise this document and to make changes from time to time in the content hereof without obligation of Emerson to notify any person of such revision or changes.
RTM and provides some information on the IPMI functionality of the RTM Appendix A, Related Documentation, on page 63 lists further Emerson user manuals that are related to the RTM and the ATCA-F120. Abbreviations...
Page 10
File > Exit Notation for selecting a submenu Notation for variables and keys [text] Notation for software buttons to click on the screen and parameter description Repeated item for example node 1, node 2, ..., node RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Page 11
No danger encountered. Pay attention to important information Summary of Changes This manual has been revised and replaces all prior editions. Part Number Publication Date Description 6806800G29A September 2008 First edition 6806800G29B January 2008 Update for Final Release (GA) RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Page 12
Mail comments to us by filling out the following online form: http://www.emersonnetworkpowerembeddedcomputing.com/ > Contact Us > Online Form In "Area of Interest" select "Technical Documentation". Be sure to include the title, part number, and revision of the manual and tell us how you used it. RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Emerson intends to provide all necessary information to install and handle the product in this manual. Because of the complexity of this product and its various uses, we do not guarantee that the given information is complete.
Page 14
Emerson could void the user's authority to operate the equipment. Board products are tested in a representative system to show compliance with the above mentioned requirements.
Page 15
Therefore, carefully inspect the RTM and the backplane for both pin and component integrity before installation. Emerson and our suppliers take significant steps to ensure there are no bent pins on the backplane or connector damage to the blades/RTMs prior to leaving the factory. Bent pins caused by improper installation or by inserting blades with damaged connectors could void the ECC warranty for the backplane or blades.
Page 16
Only remove the optical plug when you are ready to connect a cable to the SFP/SFP+ module. When no cable is connected, cover the port with an optical port plug. Environment Always dispose of used blades, system components and RTMs according to your country’s legislation and manufacturer’s instructions. RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Produkt mit vielfältigen Einsatzmöglichkeiten handelt, können wir die Vollständigkeit der im Handbuch enthaltenen Informationen nicht garantieren. Falls Sie weitere Informationen benötigen sollten, wenden Sie sich bitte an die für Sie zuständige Geschäftsstelle von Emerson. Das System erfüllt die für die Industrie geforderten Sicherheitsvorschriften und darf ausschließlich für Anwendungen in der Telekommunikationsindustrie und im Zusammenhang...
Page 18
Sicherheitshinweise Das Produkt wurde in einem Emerson Standardsystem getestet. Es erfüllt die für digitale Geräte der Klasse A gültigen Grenzwerte in einem solchen System gemäß den FCC-Richtlinien Abschnitt 15 bzw. EN 55022 Klasse A. Diese Grenzwerte sollen einen angemessenen Schutz vor Störstrahlung beim Betrieb des Produktes in Gewerbe- sowie Industriegebieten...
Page 19
Überprüfen Sie daher das RTM sowie die Backplane vor der Installation sorgältig und stellen Sie sicher, dass sich beide in einwandfreien Zustand befinden und keine Pins verbogen sind. Emerson und unsere Zulieferer unternehmen größte Anstrengungen um sicherzustellen, dass sich Pins und Stecker von Blades/RTMs vor dem Verlassung der Produktionsstätte in einwandfreiem Zustand befinden.
Page 20
Entfernen Sie die Schutzkappe nur dann, wenn Sie beabsichtigen, ein Kabel anzuschliessen. Andernfalls belassen Sie die Schutzkappe auf dem SFP/SFP+-Modul. Umweltschutz Entsorgen Sie alte Batterien und/oder Blades/Systemkomponenten/RTMs stets gemäß der in Ihrem Land gültigen Gesetzgebung, wenn möglich immer umweltfreundlich. RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Introduction Features The RTM-ATCA-F120-OPT is a rear transition module (RTM) as defined in the PICMG 3.0 revision 2.0 AdvancedTCA Base Specification for AdvancedTCA systems. It is designed to be used with the ATCA-F120 base blade and provides the following I/O interfaces towards the...
Page 22
Introduction Figure 1-1 Overview RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Introduction Standard Compliances This RTM-ATCA-F120-OPT meets the following standards. Table 1-1 Standard Compliances Standard Description UL 60950-1 Legal safety requirements EN 60950-1 IEC 60950-1 CAN/CSA C22.2 No 60950-1 CISPR 22 EMC requirements (legal) on system level (predefined Emerson system) CISPR 24...
Table 1-2 Mechanical Data Feature Value Physical dimension of PCB 322.25 mm x 70 mm Weight of RTM 0.7 kG Ordering Information Consult your local Emerson sales representative for available RTM variants and their order numbers.. RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Before touching the blade or electronic components, make sure that your are working in an ESD-safe environment. To inspect the shipment, perform the following steps. Shipment Inspection 1. Verify that you have received all items of your shipment: Printed user manual (Getting Started guide) RTM-ATCA-F120-OPT RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Operating temperatures refer to the temperature of the air circulating around the RTM, and not to component temperatures. If you integrate the RTM in your own, non-Emerson, system, please contact your local sales representative for further safety information. RTM Damage High humidity and condensation on the RTM surface causes short circuits.
1,200 mm/all edges and corners 1.0m (Packaged) per ETSI 300 019-2-2 (Blade level packaging) 100mm (unpackaged) per GR-63- CORE 2.3.2 Power Requirements The RTM has a typical power dissipation of 22W, and a maximum power dissipation of 30W. RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Installing the RTM with other blades than the ATCA-F120 may damage the RTM and the front blade. Only install the RTM with the Emerson ATCA-F120 blade. Damage of Circuits Electrostatic discharge and incorrect RTM installation and removal can damage circuits or shorten their life.
Page 29
Continue to gently push the RTM until the RTM connectors engage. 8. Squeeze the lever and the latch together and hook the lower and the upper handle into the shelf rail recesses. RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Page 30
RTM. 11.Tighten both face plate screws on the RTM. 12.Wait until the blue LEDs of both the front blade and the RTM are OFF. RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Page 31
4. Slide the RTM into the slot. 5. Apply equal and steady pressure to the RTM to carefully slide the RTM into the shelf until you feel resistance. Continue to gently push the RTM until the RTM connectors engage. RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Page 32
RTM are illuminated permanently. This indicates that the IPMC of the front blade and the MMC of the RTM are powered up. 10.Close the handles of the front blade. RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Removing the RTM from the system while the payload of the front blade is powered up may damage the front blade and RTM. Whenever removing the RTM from the system, you have to power down the payload of the front blade first. RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Page 34
2. Wait until the blue LEDs on both the front blade and the RTM are permanently ON. A permanently switched ON LED indicates that the payload of respective blade or RTM has been powered down. RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
RTM. Not complying to these regulations, may lead to personal injury. When installing and using optical SFP/SFP+ modules which are classified as laser products, make sure to comply to the respective regulations. RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Page 36
SFP/SFP+ modules can be installed/removed both while the RTM is powered and non- powered. The presence and also the type of SFP/SFP+ modules is automatically detected. The maximum power consumption of all installed SFP/SFP+ modules must not exceed 12W. RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
2.5.1 Installing an SFP/SFP+ Module Procedure In order to install an SFP/SFP+ module, proceed as follows: 1. Slide the SFP/SFP+ module into the slot until it locks into position. 2. Remove the optical port plug. RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Page 38
Only remove the optical plug when you are ready to connect a cable to the SFP/SFP+ module. When no cable is connected, cover the port with an optical port plug. 3. Connect the network cable to the SFP/SFP+ module RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
1. Remove any connected cable from the SFP module. 2. Open the SFP/SFP+ latch. Note that the latch mechanism of your SFP/SFP+ module may be slightly different compared to the latch shown in the following figure. RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Page 40
SFP/SFP+ module inoperable. Only remove the optical plug when you are ready to connect a cable to the SFP/SFP+ module. When no cable is connected, cover the port with an optical port plug. RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Chapter 3 Controls, LEDs and Connectors Overview This chapter describes: Face plate LEDs Face plate Interface connectors Rear panel connectors RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Controls, LEDs and Connectors LEDs and Interface Connectors The following figure shows the face plate of the RTM. Figure 3-1 Face Plate RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Permanently blue: RTM is powered down and is ready to be extracted. OFF: RTM is active and cannot be removed. 3.2.2 Interface Connectors The RTM provides access to the following interfaces at its face plate. Six Fabric Channel interface uplinks Six Base channel interface uplinks RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
The RTM provides access to the following six Ethernet fabric channel uplink interfaces at its face plate: Four 10 Gigabit Ethernet uplink interfaces via SFP+ connectors Two 1 Gigabit Ethernet interfaces via SFP connectors Their location is shown in the following figure. RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
(FTLX1471D3BCL). Orderable via Emerson P/N: 5806803A01 These modules passed all tests sucessfully without incidents. They are also listed in the Emerson Network Power sales configurator. When using SFP+ modules, we recommend to use these models. The SFP/SFP+ modules can be installed/removed both while the RTM is powered and non- powered.
Base Channel Interface Connectors The RTM provides access to the folllowing six Ethernet base channel uplink interfaces at its face plate: Two 10 Gigabit Ethernet uplink interfaces via SFP+ connectors Four 1 Gigabit Ethernet interfaces via SFP connectors RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
(FTLX1471D3BCL). Orderable via Emerson P/N: 5806803A01 These modules passed all tests sucessfully without incidents. They are also listed in the Emerson Network Power sales configurator. When using SFP+ modules, we recommend to use these models. The SFP+ modules can be installed/removed both while the RTM is powered and non-powered.
Periodic heartbeat messages are transmitted until a connection has been established. Once established, all channels begin operating normal levels. RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
3.2.2.4 Telecom Clocking Connectors The RTM provides two telecom clock extension connectors, named CH2 and CH3, at its face plate. Their location is shown in the following figure. Figure 3-4 Location of Clock Extension Connectors RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
These connectors allow the RTM to distribute telecom clocking signals generated by an appropriate AMC module installed on the ATCA-F120 to two external shelves. The telecom clocking interfaces are currently not supported. Consult your local Emerson sales representative for further details.
Controls, LEDs and Connectors Figure 3-5 Location of Serial Interface Connectors Serial Interface Connector RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Controls, LEDs and Connectors The following table describes the used pinout of the RJ-45 connector. Table 3-6 Serial Interface - Pinout Signal n.c. n.c. n.c. RTM_RX RTM_TX n.c. n.c. RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Chapter 4 Functional Description Overview This chapter contains the following information: Block diagram Mezzanine management controller RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
LOS SFP12 Other FRU 0x2B Present SFP01 Other FRU 0x10 Present SFP02 Other FRU 0x11 Present SFP03 Other FRU 0x12 Present SFP04 Other FRU 0x13 Present SFP05 Other FRU 0x14 Present SFP06 Other FRU 0x15 RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Page 58
Temperature 0x44 Temp. SFP06 Temperature 0x45 Temp. SFP07 Temperature 0x46 Temp. SFP08 Temperature 0x47 Temp. SFP09 Temperature 0x48 Temp. SFP10 Temperature 0x49 Temp. SFP11 Temperature 0x4A Temp. SFP12 Temperature 0x4B Top Edge Temp Temperature 0xA1 RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Page 59
TX Fault SFP09 Other FRU 0x38 TX Fault SFP10 Other FRU 0x39 TX Fault SFP11 Other FRU 0x3A TX Fault SFP12 Other FRU 0x3B The following figure shows the location of the on-board temperature sensors. RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Functional Description Figure 4-2 Location of IPMI Temperature Sensors T op E dge T emp R TM RptrTemp Bottom EdgeTemp RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Page 61
Functional Description For further details about these sensors as well as further IPMI-related information, refer to the RTM-ATCA-F120-OPT: Control via IPMI Programmer's Reference. RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Page 62
Functional Description RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Power - Embedded Computing product documentation. Check the Emerson website or consult your local Emerson sales representative for release notes or errata sheets that may be applicable to the ATCA-F120 or the RTM-ATCA-F120-OPT. Table A-1 Emerson Publications Document Title and Source Publication Number ATCA-F120: Control via IPMI Programmer’s Reference...
Page 64
Related Documentation RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Environmental requirements Fabric channel connectors Face plate feedback Installation procedure IPMI sensors LEDs Main features Mezzanine management controller Removal procedure SFP/SFP+ module hot swap capabilities Standard compliances Supported SFP/SFP+ modules Temperature sensors RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Page 66
Index RTM-ATCA-F120-OPT Installation and Use (6806800G29B)
Page 68
Precision Cooling Surge & Signal Protection Emerson, Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. All other product or service names are the property of their respective owners.