Bosch AMC2-4R4 Installation Manual

Access modular controller
Hide thumbs Also See for AMC2-4R4:

Quick Links

Access Modular Controller
AMC2-4R4
en
Installation Manual
Table of Contents
loading

Summary of Contents for Bosch AMC2-4R4

  • Page 1 Access Modular Controller AMC2-4R4 Installation Manual...
  • Page 3: Table Of Contents

    RS-485 Host Interface 4.9.1 RS-485 Two Wire Connection 4.9.2 RS-485 Four Wire Connection 4.10 RS-232 Host Interface 4.11 DIL switch selector 4.11.1 Host settings 4.12 RS-485 for extension modules 4.13 RS-485 Interface for Card Readers Bosch Sicherheitssysteme GmbH 2013-08 | AMC2-4R4 |...
  • Page 4 4.16 Tamper Protection Operating Status Display of the AMC2 Configuring the Ethernet Interface Resetting the AMC2 5.3.1 Resetting the Software 5.3.2 Resetting the Device to Factory Default Technical Data Appendices Connecting Diagrams Index 2013-08 | AMC2-4R4 | Bosch Sicherheitssysteme GmbH...
  • Page 5: Safety Instructions

    If the unit has been exposed to water and/or inclement weather (rain, snow, etc.). – If the unit does not operate normally when following the operating instructions. Adjust only those controls specified in the operating instructions. Improper Bosch Sicherheitssysteme GmbH 2013-08 | AMC2-4R4 |...
  • Page 6 10. Lightning - For added protection during electrical storms external lightning conductors can be installed. This prevents power surges from damaging the unit. 11. The units should be installed in locations with restricted access. 2013-08 | AMC2-4R4 | Bosch Sicherheitssysteme GmbH...
  • Page 7: Safety Precautions

    Ideally, use a magnetic lock. Install a normally-closed break glass or a manual pull (B) in the lock supply wiring, so that in an emergency the fail-safe lock can be immediately powered down. Bosch Sicherheitssysteme GmbH 2013-08 | AMC2-4R4 |...
  • Page 8: Unpacking

    If any parts are missing, inform your customer service representative or a Bosch Security Systems salesperson. The shipping carton is the safest transport container for the unit. Store it and the other packaging material for future use. If the unit has to be sent back, use the original packaging.
  • Page 9: Important Information

    Bosch Security Systems retains all rights not expressly granted. Nothing in this license constitutes a waiver of Bosch’s rights under the U.S. Copyright laws or any other federal or state law. If you have any questions concerning this license, please, write...
  • Page 10: Internet

    Tips and shortcuts may also be included in such notes. Internet If you are interested in further information on this product or information on other products, please consult our website at http://www.boschsecurity.com. 2013-08 | AMC2-4R4 | Bosch Sicherheitssysteme GmbH...
  • Page 11: Introduction

    Controller Introduction Description The AMC2-4R4 (also called AMC2 or controller) is equipped with four independent interfaces for RS-485 type readers. It is able to control four doors with a reader in each direction and up to eight doors with a reader in one direction only.
  • Page 12 The extensions offer 8 or 16 additional inputs and outputs. The setup procedure for an AMC2-4R4 is made very simple and fast by the use of door templates. Once selected, all the inputs and outputs are predefined. These settings can be changed to choose every free contact of the controller or a connected extension.
  • Page 13: Equipment Configuration

    8 years. Spare part: VARTA CR 2032 PCB. Reset push button - reachable through the casing using a screwdriver Liquid Crystal Display Push button, available on top of the housing, to select different display modes Bosch Sicherheitssysteme GmbH 2013-08 | AMC2-4R4 |...
  • Page 14 12 Configurable 10/100 Mbit/s Ethernet host interface Figure 3.4: Overview - Interfaces 13 RS-485 extension module bus 14 External tamper contact 15 Connector for power supply 16 RS-485 interfaces for up to card readers 2013-08 | AMC2-4R4 | Bosch Sicherheitssysteme GmbH...
  • Page 15: Performance Characteristics

    (shield) for the extension interface. Performance Characteristics – Intelligent access manager for 1 - 8 entrances (for example doors, man traps, barriers) – Host address selectable using DIL sliding switch. Bosch Sicherheitssysteme GmbH 2013-08 | AMC2-4R4 |...
  • Page 16: System Overview

    PBC-60 (F.01U.026.573) with integrated uninterruptable power supply (UPS). System Overview The Access Controller AMC2-4R4 is connected between the management host system and different peripheral devices. By default, a management host system is connected using Ethernet. A management host connection using RS-485 or RS-232 is also possible.
  • Page 17 Ethernet System configurations for Access Control applications – The minimum configuration consists of – one PC with system software – one AMC2 controller – one AMC PBC-60 power supply – one AMC enclosure Bosch Sicherheitssysteme GmbH 2013-08 | AMC2-4R4 |...
  • Page 18 The extension interface supports up to three additional I/O boards (AMC2-8IOE, AMC2-16IE, or AMC2-16IOE). All extension boards are controlled by the AMC2 and are freely combinable. 2013-08 | AMC2-4R4 | Bosch Sicherheitssysteme GmbH...
  • Page 19: Installing

    Controller Installing Mounting The AMC2-4R4 can be attached on a standard 35 mm (1.377 in.) mounting rail using a snap-in mechanism. Attach the AMC2-4R4 into the upper edge of the mounting rail [1], then push down the device and snap it onto the rail by pushing it towards the back [2].
  • Page 20: Unmounting

    To remove the AMC2-4R4 from a mounting rail, first remove all pluggable connectors. Push down the AMC2-4R4 until the lower edge snaps out of the mounting rail [1]. Pull the lower end of the AMC2-4R4 from the mounting rail [2].
  • Page 21: Opening The Case

    Notice! To open the AMC2-4R4, first remove all pluggable connectors. The AMC2-4R4 case consists of a top cover mounted with a two- point snap-in closure on a chassis. To open the case, push down the two snap-ins with a screwdriver, then swing the cover down.
  • Page 22: Closing The Case

    Insert the hooks on the lower edge of the front cover into the lugs on lower edge of the plastic back cover [1]. Please ensure that the BOSCH logo is not upside-down. The upper edge of the front cover now aligns with the two-point snap-in closures on the upper edge of the back cover [2], and may thus be clicked gently into place.
  • Page 23: Cabling

    Cabling Notice! Risk of malfunction The cables used in the AMC2-4R4 access control system are not prone to electrical interference. However, you should avoid routing cables close to heavy load switching cables and equipment. If this is unavoidable, cross the cable at right angles every 1 to 2 m (3 to 6 ft) to reduce interference.
  • Page 24 | Installing Controller Notice! These specifications apply to power supply, readers, relay outputs, and extension interface. Regarding inputs, specific voltage-drop values need to be taken into account. Refer to Connecting Analog Input Devices, page 2013-08 | AMC2-4R4 | Bosch Sicherheitssysteme GmbH...
  • Page 25: Grounding And Shielding

    Installing | en Controller Grounding and Shielding The main grounding point at the AMC2-4R4 is connected to pin 2 of the power supply connector – see Connecting Diagrams, page 58. It is good practice to shield all wires carrying low level signals.
  • Page 26: Grounding For Host Interface

    Figure 4.5: Location of ground jumper RS-485 host interface The jumper setting A1 shows the factory settings. Jumper JP1 connects the internal ground of the AMC2-4R4 to the ground of the RS-485 host interface. Jumper JP2 manages the signal ground.
  • Page 27: Grounding For Extension Interface

    Access Modular Installing | en Controller Notice! If the AMC2-4R4 is set to RS-232 mode, set jumper JP1 (= A2). 4.6.2 Grounding for Extension Interface Figure 4.6: Location of ground jumper bottom side Jumper B connects the internal ground of the AMC2-4R4 to the RS-485 ground of the slave interface.
  • Page 28: Grounding For Bus Interfaces

    AMC2 to the RS-485 ground of the bus. Only set jumper C and D (C2 or D2) if the AMC2 powers all other peripheral devices which are directly connected to the AMC2. 2013-08 | AMC2-4R4 | Bosch Sicherheitssysteme GmbH...
  • Page 29: Connecting Power Supply

    – pin 4 and 7 for power good AC – pin 5 and 7 for power good Battery – pin 6 and 7 for power good DC Otherwise these pins must be short-circuited. Bosch Sicherheitssysteme GmbH 2013-08 | AMC2-4R4 |...
  • Page 30: Ethernet Host Interface

    The AMC2-4R4 offers a 10/100 Mbit/s Ethernet auto-sensing interface to connect to a local area network or host computer. Notice! Use either a CAT5 crossover cable to connect the AMC2-4R4 directly to host computer, or a standard CAT5 patch cable to connect the AMC2-4R4 via a network.
  • Page 31: Rs-485 Host Interface

    An RS-485 host system can consist of up to eight AMC2 controllers connected using 2- or 4-wire connection. Figure 4.10: Configuration of a RS-485 host system Host RS-232 connection RS-232 / RS-485 converter RS-485 bus AMC2 controller Bosch Sicherheitssysteme GmbH 2013-08 | AMC2-4R4 |...
  • Page 32 Any bus line conductor connects up to eight AMC2. Do not exceed the maximum number of devices. To use RS-485 mode at the AMC2-4R4 , connect the data cables to the pluggable screw connector of the RS-485 host interface. The setting of the AMC2-4R4 must correspond with the settings of the RS-232 / RS-485 converter.
  • Page 33: Rs-485 Two Wire Connection

    Figure 4.13: Settings for RS-485 four wire connection Notice! See the notices for setting the RS-232 / RS-485 converter. Notice! If a four-wire connection is used the interface must be set up as a crosslink. Bosch Sicherheitssysteme GmbH 2013-08 | AMC2-4R4 |...
  • Page 34: Rs-232 Host Interface

    As the AMC2 controller is conceptionally a PC, it is not possible to connect them directly using normal cables. Use instead a null modem or “crossover” cable. A complete connection diagram of the RS-232 host interface is shown in chapter Connecting Diagrams, page 58 2013-08 | AMC2-4R4 | Bosch Sicherheitssysteme GmbH...
  • Page 35: Dil Switch Selector

    If using an RS-232 connection, set the address by configuring it in the Access Control System. This is a point-to-point connection that is usually configured as address 1, so set switch 1 to ON. Figure 4.15: Location of the selector for host settings Bosch Sicherheitssysteme GmbH 2013-08 | AMC2-4R4 |...
  • Page 36 RS-485 host connection with more than one and maximum eight AMC2s per bus Notice! Changing the type of the host connection requires a reset of the AMC2 - see Resetting the Software, page 53. 2013-08 | AMC2-4R4 | Bosch Sicherheitssysteme GmbH...
  • Page 37: Rs-485 For Extension Modules

    Table 4.2: Protocol and connection settings 4.12 RS-485 for extension modules The RS-485 Extension Module Bus expands the AMC2-4R4 with additional I/O modules (AMC2-8IOE, AMC2-16IE, AMC2-16IOE). Figure 4.16: Location of the RS-485 extension module bus Up to three expansion modules can be connected to provide additional in- and outputs, for example, for elevator control.
  • Page 38: Rs-485 Interface For Card Readers

    Figure 4.17: Connection of an extension module to an AMC2 4.13 RS-485 Interface for Card Readers The AMC2-4R4 has four RS-485 interfaces. Each interface is connected using a 10-pin pluggable screw connector (S2, S7, S14, and S19). 2013-08 | AMC2-4R4 |...
  • Page 39 However the addresses of the readers must be unique on an AMC2. Depending on the input voltage of the AMC2-4R4 either 12 V or 24 V is available for the readers. A complete connection diagram of the RS-485 interface is shown in chapter Connecting Diagrams, page 58.
  • Page 40 Readers that are not suitable for this voltage will be damaged. Notice! Keep in mind the cable length limitations and conditions of a RS-485 bus system as described in RS-485 Host Interface, page 2013-08 | AMC2-4R4 | Bosch Sicherheitssysteme GmbH...
  • Page 41: Connecting Relay Outputs

    Controller 4.14 Connecting Relay Outputs To operate locks or alarm systems, the AMC2-4R4 has eight form C relay outputs. The outputs will be connected to the 3-pin pluggable screw connectors S5, S6, S10, S11, S17, S18, S22, and S23 - refer to Connecting Diagrams, page 58.
  • Page 42 – inductive loads have to be short circuited using recovery diodes, see image below. These diodes (1N4004) are supplied with every AMC2-4R4 package. – If you need higher voltage for special applications you can connect external relays to the outputs. Recommended,...
  • Page 43 Notice! Risk of damage to equipment Do not connect externally powered devices in wet mode. This can damage the AMC2-4R4. Bosch Sicherheitssysteme GmbH 2013-08 | AMC2-4R4 |...
  • Page 44 Controller Each relay output has a separate jumper setting on the underside of the circuit board to select dry (E1) or wet (E2) mode. Figure 4.22: Location of relay output jumpers (bottom side) 2013-08 | AMC2-4R4 | Bosch Sicherheitssysteme GmbH...
  • Page 45: Connecting Analog Input Devices

    Controller 4.15 Connecting Analog Input Devices The AMC2-4R4 has 8 analog inputs, for example, for potential- free lock mechanisms, or to detect whether a lock is closed or open. The inputs will be connected to the 2-pin pluggable screw connectors: S3, S4, S8, S9, S15, S16, S20 and S21 - refer to Connecting Diagrams, page 58.
  • Page 46 To detect the four states, the voltage drop in the connecting cable may not exceed special values. The following table shows the maximum values of permissible cable resistance depending on the used resistor combination. 2013-08 | AMC2-4R4 | Bosch Sicherheitssysteme GmbH...
  • Page 47 1800 1900 Table 4.3: Maximum values of cable resistance per used resistor combination in Ohm Notice! We recommend using serial resistors (R ) no higher than 5K6 in order to obtain clear measurements. Bosch Sicherheitssysteme GmbH 2013-08 | AMC2-4R4 |...
  • Page 48: Tamper Protection

    | Installing Controller 4.16 Tamper Protection To protect the AMC2-4R4 against unauthorized access and so prevent tampering with sensitive data, the AMC2-4R4 provides an additional interface to connect external tamper contacts. This interface is a potential-free 2-pin pluggable screw connector marked with T.
  • Page 49: Operating

    Operating Status Display of the AMC2 The liquid crystal display delivers status information about the AMC2-4R4. Push the 'Dialog' button to switch between different modes. Figure 5.1: Location of the ’Dialog’ button The selected display mode remains set until the next time the button is pressed.
  • Page 50 IP-address of the gateway (Version V 00.44 or higher) M 255.255.255.0 Subnetmask (Version V 00.44 or higher) H 192.168.10.10 IP-address of the host computer DHCP 1 DHCP-status: 1 = on 0 = off 2013-08 | AMC2-4R4 | Bosch Sicherheitssysteme GmbH...
  • Page 51 Host activity: + = online - = offline "C" = Counter of the received data packages from the host interface. RS 485 Bus connection: A = Address 1 … H = Address 8 Bosch Sicherheitssysteme GmbH 2013-08 | AMC2-4R4 |...
  • Page 52: Configuring The Ethernet Interface

    Access Modular en | Operating Controller Configuring the Ethernet Interface To configure the AMC2-4R4 in a TCP/IP network environment, use the AmcIpConfig tool provided in the following directory on the standalone or the remote server of the Building Integration System:...
  • Page 53: Resetting The Amc2

    The AMC2-4R4 deletes its application program leaving only its bootloader and network setting. As soon as it is online again, the AMC2-4R4 bootloader will download a fresh copy of the application program and configuration. If the problem persists please request technical support.
  • Page 54: Resetting The Device To Factory Default

    5.3.2 Resetting the Device to Factory Default Reset the AMC2-4R4 as described above. Open the upper case of the AMC2-4R4 as described in Opening the Case, page 21. Set all six DIL switches of the RS-485 selector to ON as shown in the figure below.
  • Page 55: Technical Data

    1,25 A – operating ratings (wet and dry): 1,25 A @ 30 Vdc 2 A @ 12 Vdc 1,5 A @ 24 Vdc – Eight analog inputs with sabotage monitoring; only connect dry contacts Bosch Sicherheitssysteme GmbH 2013-08 | AMC2-4R4 |...
  • Page 56 0° C to 45° C (32° F to 113° F) Humidity Up to 95%, without condensation Housing material ABS with OC (UL 94 V-0) Dimensions (W/H/D) 232 x 90 x 63mm (8.9 x 3.5 x 2.5 in) 2013-08 | AMC2-4R4 | Bosch Sicherheitssysteme GmbH...
  • Page 57 Controller Weight approx. 0.53kg (1.2lb) Notice! The voltage drop from the power supply to the AMC2-4R4 affects the AMC interfaces. The total drop must not exceed 2V! Notice! To determine the environmental impact of an installation, take into account the most extreme values of all participating devices.
  • Page 58: Appendices

    Figure 7.1: Connectors on upper PCB Shield Data RxTx+ (2-wire) Data Rx+ (4-wire) Data RxTx- (2-wire) Data Rx- (4-wire) Ground (PAG) Data Tx+ (4-wire) Data Tx- (4-wire) Table 7.1: RS-485 host on upper PCB 2013-08 | AMC2-4R4 | Bosch Sicherheitssysteme GmbH...
  • Page 59 Access Modular Appendices | en Controller TXD+ TXD- RXD+ not connected not connected RXD- not connected not connected Table 7.2: Ethernet Network socket (RJ45) Figure 7.2: Interconnect diagram of the RS-232 serial interface Bosch Sicherheitssysteme GmbH 2013-08 | AMC2-4R4 |...
  • Page 60 Access Modular en | Appendices Controller Figure 7.3: Connector blocks of the AMC2-4R4 2013-08 | AMC2-4R4 | Bosch Sicherheitssysteme GmbH...
  • Page 61 Reader Supply (0V) Shield Data RxTx+ Data RxTx- Data shield (PAG) not connected not connected not connected not connected Table 7.4: RS-485 reader interface Analog Input, in Analog Input, out Table 7.5: Analog input Bosch Sicherheitssysteme GmbH 2013-08 | AMC2-4R4 |...
  • Page 62 Power supply for external devices (10V - 30V) Power supply for external devices (0V) Shield Data RxTx+ Data RxTx- Ground (PAG) Table 7.7: Host / Extension interface Tamper Contact, in Tamper Contact, out Table 7.8: External tamper contact 2013-08 | AMC2-4R4 | Bosch Sicherheitssysteme GmbH...
  • Page 63: Index

    25 interfaces system overview, 16 Ethernet, 52 extension, 27, 56 tamper, 48 host, 16, 30, 31, 34, 55 transfer rates, 16, 55 reader, 16, 55 RS-485, 38 unmounting, 20 interfades extension, 37 Bosch Sicherheitssysteme GmbH 2013-08 | AMC2-4R4 |...
  • Page 66 Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.com © Bosch Sicherheitssysteme GmbH, 2014...