Siemens WS 400-30 Description

Operator panels

Quick Links

Equipment for Machine Tools
WS 400-30/WS 400-50
Operator Panels
Description
May 1992 Edition
Table of Contents
loading

Summary of Contents for Siemens WS 400-30

  • Page 1 Equipment for Machine Tools WS 400-30/WS 400-50 Operator Panels Description May 1992 Edition...
  • Page 2 This publication was produced on the Siemens 5800 Office System. Subject to change without prior notice. The reproduction, transmission or use of this document contents permitted without express written authority. Offenders will be liable for damages. All rights, including rights created by patent grant or registration of a utility model or design, are reserved.
  • Page 3 Area of Application Design Description of Keypads Connection of the Operator Panels Technical Data Ordering Data Appendix...
  • Page 5: Table Of Contents

    WS 400-30 for WF 470 ........
  • Page 7: Area Of Application

    • The WS 400-30 and WS 400-50 operator panels cope with these requirements. They are de- signed for machine-level application in an industrial environment. On this basis, a range of standard operator panels has been put together for the user. The op- erator panels have all the keys needed for convenient operation of the various graphic and control systems.
  • Page 9: Design

    The keypads and the softkey panel are connected to the units by a keyboard encoder. The keyboard encoder is built in to the WS 400-30 and WS 400- 50 basic units. In addition, a WS 400-30 operator panel is available for universal use.
  • Page 10: Ws 400-50 For Gracis

    The softkey panel and the GRACIS keypad contain all the keys needed for convenient opera- tion at the planning stage and during GRACIS process operation. 2 - 2 © Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 11 GRACIS process operation. Keypad Expansion Unit (Typewriter Layout) An alphanumeric keypad with digits, punctuation marks and special characters is built in to the keypadexpansion unit. © 2 - 3 Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 12: Ws 400-30 For Gracis

    WS 400-30 for GRACIS SIEMENS The WS 400-30 operator panel is equipped with: • a softkey panel with 16 function keys • five 22.5-mm diameter drilled holes on each side of the screen for 3SB... probes • a programming unit keyboard interface The drilled holes on both sides of the screen go through to the back of the operator panel and can be used for mounting switching or pushbutton units.
  • Page 13: Ws 400-50 For Wf 470

    Keypad Expansion Unit An alphanumeric keypad with digits, punctuation marks and special characters is built in to the keypad expansion unit. © 2 - 5 Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 14: Ws 400-30 For Wf 470

    WS 400-30 for WF 470 SIEMENS The WS 400-30 operator panel connection to the WF 470 diagnostics and display system is fit- ted with a softkey panel of 16 function keys and has five drilled holes on both sides of the screen.
  • Page 17: Description Of Keypads

    (key code of the special keys with the Shift key pressed) SL means Shift Lock (key code of the special keys with Shift Lock on) © 3 - 1 Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 18: Softkey Panel With 16 Function Keys

    06 16 ALT F6 ALT Shift F6 07 12 07 16 ALT F7 ALT Shift F7 08 12 08 16 ALT F8 ALT Shift F8 3 - 2 © Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 19 2D 00 2D 00 2E 00 2E 00 61 00 41 00 62 00 42 00 63 00 43 00 64 00 44 00 © 3 - 3 Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 20: Keypad For Wf 470

    Keypad for WF 470 The WS 400-50's keypad for the WF 470 is built in to the operator panel. In the case of the WS 400-30, the keypad for the WF 470 is in the keypad expansion unit. WF 470 Key Codes...
  • Page 21: Gracis Keypad Version A

    If a hashmark (#) is printed before one of the numbers in the table below, this means that the operator must press the corresponding number key on the programming unit's keypad. © 3 - 5 Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 22 ALT # 21 00 21 02 21 00 ALT ! 20 00 20 02 20 00 37 00 37 02 37 00 ALT 7 3 - 6 © Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 23 0F 00 4C 02 0F 00 Ctrl O ALT L 17 00 02 20 17 00 Ctrl W Ctrl+ 0D 00 0A 10 0D 00 © 3 - 7 Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 24 1B 00 1B 02 ALT Esc 17 00 02 20 Ctrl W Ctrl+ BACKSPACE 08 00 49 02 ALT I 0D 00 0A 10 3 - 8 © Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 25: Alphanumeric Keys

    50 00 – 2D 00 2D 02 2D 00 – ALT – 2E 00 3A 00 2E 00 61 00 41 00 41 00 © 3 - 9 Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 26 62 00 42 00 42 00 6E 00 4E 00 4E 00 6D 00 4D 00 4D 00 0D 00 0D 02 0D 00 3 - 10 © Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 27: Meanings Of The Key Symbols

    Delete character under the cursor Abort Open/close window Move between windows Accept Function keys Leave a level Continue a function key help dialogue call Switch operating modes © 3 - 11 Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 28: Programming Unit Connector Strip And Key-Operated Switch

    The programming unit connector socket and the key- operated switch are looped through 1:1 to the back of the operator panel to allow the connection of a PLC, for example. 3 - 12 © Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 29: Connecting The Operator Panels

    4.1.1 Module Configuration The WS 400-30 and WS 400-50 operator panels can be connected to different graphics and/or control systems. Adjustment of the operator panel setting to the connected graphics and/or control system is by means of DIL switch S1 that is built in to the keyboard encoder. Viewed from the back, the encoder is to the left of the monitor behind a cover plate.
  • Page 30: Gracis-S5

    Operator panel and programming unit keyboards enabled If a programming unit keyboard is connected to X18, it can only be used in GRACIS-PG mode (switch S1). 4 - 2 © Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 31: Keypad Identification

    X X X X GRACIS keypad version A (X 901) GRACIS keypad version B X X X X (X 701) Alphanumeric keys X X X (X 1001) © 4 - 3 Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 32: Connection To Simatic S5 Via The Parallel Interface

    For more detailed information, consult Part 2 of the GRACIS Commissioning Guide SIMATIC S5 Interface under ZFS-TAST. 4.2.2 WF 470 Connection For more detailed information, consult the WF 470 Description. 4 - 4 © Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 33: Interfaces

    Interfaces The WS 400-30/WS 400-50 flexible operator panels have one parallel and two serial interfaces (20mA and RS 232). The serial and the parallel interfaces can be assigned at the same time. Seven bits and the strobe signal are used to transmit the key codes. In the case of GRACIS, eight bits and one strobe signal are used.
  • Page 34 WS 400-30 (Universal) Rear View Mains Connection X102 4 - 6 © Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 35 WS 400-30 (GRACIS and WF 470) Rear View Maintenance Connector (Monitor) Mains Connection 24 V X101 Parallel and TTY interface V.24 interface 24-volt supply voltage X14 Softkey connection to basic unit (X101) X18 Programming unit keyboard (with GRACIS only) Because of the short connecting cable, the keypad expansion unit must be set up directly below the monitor.
  • Page 36: Parallel Interface And 20Ma Interface On Connector X1

    6FM1790-8CA00 15-pin, female Solder Side Screw interlock Active or passive setting of the 20mA interface is carried out on switch X33 (see Chapter 4.2). 4 - 8 © Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 37: V.24 Interface On Connector X2

    25-pin, male • • • • 6FM1 790-8GA00 • • • • Solder Side • • • • Screw interlock • • • 1 • © 4 - 9 Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 38: Ws 400-30 Keyboard Interface, Universal

    Connection to a SIMATIC DE module, for example Assignment of X102 PIN 18 PIN 19 This interface is universally available with the WS 400-30 operator panel only. Connection to a keyboard encoder is not possible. 4 - 10 © Siemens AG 1992 All Rights Reserved...
  • Page 39: Monitor Interface

    ”75E”. The 24V output is for voltage supply of the keyboard encoder only. Running the monitor at full contrast reduces the CRT's useful life. © 4 - 11 Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 40: Overview Of Cables

    OUT 75E HIGH IN HS/CS Switchover 495 6FM1 495-5AC00 OUT 75E HIGH IN 6FM1 490-3C 00 6FM1 490-3B 00 6FM1 490-1D 00 WF 470 WS 400-30/WS 400-50 4 - 12 © Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 41 OUT 75E HIGH IN 6FM1 490-3C 00 BLUE OUT 75E HIGH IN HS/CS OUT 75E HIGH IN 6FM1 490-1M 00 GRACIS WS 400-30/WS 400-50 © 4 - 13 Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 42 For programming units with HS/CS HIGRAPH 2 e.g. 6EA1 770-0AA11-1AA1 OUT 75E HIGH IN 6FM1 490-1PY00 Programming Unit Keyboard WS 400-30/WS 400-50 PG 770 Keyboard 4 - 14 © Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 43: Cable Plans

    – TxD – RxD +TxD Cable 5 x 0,25, shielded Housing Screen Housing Screen Connector Connector 15-pin, female 25-pin, female Solder Side Solder Side © 4 - 15 Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 44: 6Fm1 490-1D 00

    Connection to the WF 470 monitor display system Cable name.: Cable from flexible operator panels to WF 470 Order No.: 6FM1 490-1D 00 WS 400-30 / WS 400-50 WF 470 Flexible Operator Panel +TxD 12 680 +24V – TxD +RxD +RxD –...
  • Page 45: Connecting Cable For Colour Monitor

    Order No..: 6FM1 490-3C 00 3 BNC connectors 3 BNC bayonet connectors With cables that are longer than 60 m, always carry out interference correction. © 4 - 17 Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 47: Technical Data

    The units are connected to the mains by means of a socket for non-heating apparatus on the monitor. A two-metre long mains cable is supplied. © 5 - 1 Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 48 WF 470 Typewriter keyboard+keypad for WF 470 c) 16-key GRACIS version B keypad ALPHA Typewriter keyboard layout d) 75-key GRACIS version A keypad Machine control panel 5 - 2 © Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 49 WS 400-50 Rear View 482,6 130.9 120.6 Mains Connection 382.4 130.9 5.5-mm diameter drilled holes Side View © 5 - 3 Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 50 WS 400-30 Front View 54.2 ±0.2 54.2 ±0.2 SIEMENS 169,3 22.5 5 - 4 © Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 51 WS 400-30 GRACIS/WF 470 and universal Rear View 482.6 130.9 120.6 382.4 Mains Connection 130.9 5.5-mm diameter drilled holes 22.5-mm diameter drilled holes (sealed with caps) Side View © 5 - 5 Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02...
  • Page 52 Keypad Expansion Unit for WS 400-30/50 and Machine Control Panel Rear View 482.6 115.7 100.7 133.3 5.5-mm diameter drilled holes Side View 5 - 6 © Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 53: Appendix

    Appendix Order Numbers Operator Panel Version Order Number WS 400-30 for WF 470 6FM1 430-1BB10 WS 400-30 Keypad Expansion Unit for WF 470 6FM1 430-2BB10 WS 400-50 for WF 470 6FM1 450-1BB10 WS 400-50 Keypad Expansion Unit (Alphanumeric) 6FM1 450-2BB00...
  • Page 54 WS 400 6FM1 490-1PY00 (Keyboard Connection) Length Code for 6FM1 ...-..Length (Metres) 2.00 5.00 10.00 18.00 25.00 35.00 50.00 60.00 Special Length 6 - 2 © Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 55: Bibliography

    Bibliography Title Order Number 6ZB5 440-0BX01-0BA2 WS 400-30/WS 400-50 Operator Panels Product Brief GRACIS 6ZB5 440-0BK02-0BA2 Product Brief GRACIS 6ZB5 440-0BJ02-0BA1 Description GRACIS 6ZB5 440-0AJ01-0AA0 Register Manual GRACIS 6ZB5 440-0BL02-0AA2 Technical Description GRACIS 6ZB5 440-0BM01-0AA1 Installation, Part 1 GRACIS 6ZB5 440-0BN02-0AA1...
  • Page 56 6ZB5 440-0KE01-0AA8 /17/ AR 10 E86060-K6310-A101-A2-7600 WS/WF Series Systems and Components (Replaces: Ordering Aids 6ZB5 440-0JL02-0BA0 Overview of WS/WF Technology) Available in German only 6 - 4 © Siemens AG 1992 All Rights Reserved 6ZB5 440-0KP02 WS 400-30/WS 400-50 (Description)
  • Page 57: Index

    WS 400-30 for WF 470 ....WS 400-30 universal ....Interfaces .
  • Page 59 Siemens AG Suggestions/Corrections AUT - V 260 For Publication: Postfach 48 48 Equipment for Machine Tools W 8500 Nuernberg 1 WS 400-30/WS 400-50 Federal Republic of Germany Operator Panels Description Order No.: 6ZB5 440-0KP02-0BA3 Edition: May 1992 From: Should you come across any printing errors...
  • Page 60 Automation Systems for Machine Tools, Robots and Special-Purpose Machines Postfach 48 48, W-8500 Nuernberg 1 © Siemens AG 1992 All Rights Reserved Federal Republic of Germany Subject to change without prior notice Order No. 6ZB5 440-0KP02-0BA3 Siemens Aktiengesellschaft Printed in the Fed. Rep. of Germany...

This manual is also suitable for:

Ws 400-50