  • Page 3 ___________________ Safety information ___________________ General ___________________ SINAMICS Mechanical installation ___________________ Electrical installation SINAMICS G130 Sinusoidal filter ___________________ Technical specifications Operating Instructions Firmware version V5.1 11/2017 A5E00992420A...
  • Page 4 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 5: Table Of Contents

    Table of contents Safety information ........................... 5 General safety instructions ....................... 5 Handling electrostatic sensitive devices (ESD) ..............10 General ..............................11 Mechanical installation .......................... 15 Electrical installation..........................17 Technical specifications ........................19 Sinusoidal filter Operating Instructions, 11/2017, A5E00992420A...
  • Page 6 Table of contents Sinusoidal filter Operating Instructions, 11/2017, A5E00992420A...
  • Page 7: Safety Information

    Safety information General safety instructions WARNING Electric shock and danger to life due to other energy sources Touching live components can result in death or serious injury. • Only work on electrical equipment if you are appropriately qualified. • Always observe the country-specific safety rules for all work. Generally, the following steps apply when establishing safety: 1.
  • Page 8 Safety information 1.1 General safety instructions WARNING Electric shock due to equipment damage Improper handling may cause damage to equipment. For damaged devices, hazardous voltages can be present at the enclosure or at exposed components; if touched, this can result in death or severe injury. •...
  • Page 9 • If you come closer than around 2 m to such components, switch off any radio devices or mobile phones. • Use the "SIEMENS Industry Online Support App" only on equipment that has already been switched off. WARNING Motor fire in the event of insulation overload There is a greater load on the motor insulation as result of a ground fault in an IT system.
  • Page 10 Safety information 1.1 General safety instructions WARNING Fire due to inadequate ventilation clearances Inadequate ventilation clearances can cause overheating of components with subsequent fire and smoke. This can cause severe injury or even death. This can also result in increased downtime and reduced service lives for devices/systems. •...
  • Page 11 Safety information 1.1 General safety instructions Note Important safety instructions for Safety Integrated functions If you want to use Safety Integrated functions, you must observe the safety instructions in the Safety Integrated manuals. Sinusoidal filter Operating Instructions, 11/2017, A5E00992420A...
  • Page 12: Handling Electrostatic Sensitive Devices (Esd)

    Safety information 1.2 Handling electrostatic sensitive devices (ESD) Handling electrostatic sensitive devices (ESD) Electrostatic sensitive devices (ESD) are individual components, integrated circuits, modules or devices that may be damaged by either electric fields or electrostatic discharge. NOTICE Damage through electric fields or electrostatic discharge Electric fields or electrostatic discharge can cause malfunctions through damaged individual components, integrated circuits, modules or devices.
  • Page 13: General

    General Description The sine-wave filter limits the voltage gradient and the capacitive charge/discharge currents which usually occur with inverter operation. It also prevents additional noise caused by the pulse frequency. The service life of the motor is as long as that attained with direct mains operation.
  • Page 14 When using components that have not been released, damage or malfunctions can occur at the devices or the system itself. • Only use sine-wave filters that SIEMENS has released for SINAMICS. NOTICE Risk of damaging the sine-wave filter by exceeding the maximum output frequency The maximum permissible output frequency when sine-wave filters are used is 115 Hz or 150 Hz.
  • Page 15 Note If a filter cannot be parameterized (p0230 ≠ 3) during commissioning, then no provision is made for this SIEMENS sine-wave filter for the SINAMICS G130. Sinusoidal filter Operating Instructions, 11/2017, A5E00992420A...
  • Page 16 General Table 2- 2 Technical specifications for sine-wave filters with SINAMICS G130 Article number Voltage Pulse frequency Output current SINAMICS G130 [kHz] 6SL3310-1GE32-1AA3 3-phase 380 – 480 172 A 6SL3310-1GE32-6AA3 3-phase 380 – 480 216 A 6SL3310-1GE33-1AA3 3-phase 380 – 480...
  • Page 17: Mechanical Installation

    Mechanical installation Dimension drawing Figure 3-1 Dimension drawing, sine-wave filter Sinusoidal filter Operating Instructions, 11/2017, A5E00992420A...
  • Page 18 Mechanical installation Table 3- 1 Dimensions of the sine-wave filter (all values in mm) 6SL3000- 2CE32-3AA0 2CE32-8AA0 2CE33-3AA0 2CE34-1AA0 2CF31-7AA0 The lengths n1, n2 and n3 correspond to the drill hole spacing Sinusoidal filter Operating Instructions, 11/2017, A5E00992420A...
  • Page 19: Electrical Installation

    Electrical installation Connection When connecting the sine-wave filter, you must take into account the following conditions to ensure that the filter functions correctly: ● With analog control cables, connecting the shield at both ends can result in coupled-in noise. To prevent this, the shield must only be connected at one end on the Power Module.
  • Page 20 Electrical installation Sinusoidal filter Operating Instructions, 11/2017, A5E00992420A...
  • Page 21: Technical Specifications

    Technical specifications General technical data Table 5- 1 General technical data Output frequency 380 V - 480 V 3 AC: 0 ... 150 Hz 500 V - 600 V 3 AC: 0 ... 115 Hz Product standard EN 61800-5-1 Ambient conditions Storage Transport Operation...
  • Page 22 Technical specifications Detailed technical data Table 5- 2 Technical data for sine-wave filters, 3 AC 380 V ... 480 V Article number 6SL3000- 2CE32-3AA0 2CE32-3AA0 2CE32-8AA0 2CE33-3AA0 2CE34-1AA0 Suitable for Power Mod- 6SL3310- 1GE32-1AA3 1GE32-6AA3 1GE33-1AA3 1GE33-8AA3 1GE35-0AA3 Rated current (unit rat- 170 A 215 A 270 A...
  • Page 23 Technical specifications Table 5- 3 Technical data for sine-wave filters, 3 AC 500 V ... 600 V Article number 6SL3000- 2CF31-7AA0 2CF31-7AA0 Suitable for Power Mod- 6SL3310- 1GF31-8AA3 1GF32-2AA3 Rated current (unit rat- 152 A 187 A ing) of the Power Module (90 kW) (110 kW) at a 2.5 kHz pulse fre-...