  • Page 1 Installation Manual SIMATIC NET Rugged Multi Service Platforms RUGGEDCOM RX1400 For RX1400 Edition 09/2019 https://www.siemens.com...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Multi Service Platforms RUGGEDCOM RX1400 Communication Ports Technical Specifications Installation Manual Certification For RX1400 09/2019 C79000-G8976-1103-13...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommend- ed or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing Documentation ....................... v Disclaimer of Liability ......................v Registered Trademarks ......................v Training ..........................vi Customer Support ........................vi Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................1 Description ......................2 Required Tools and Materials ................. 4 Decommissioning and Disposal ................
  • Page 5 ISED ........................48 6.1.9 RRA ........................51 6.1.10 ANATEL ....................... 52 6.1.11 ICASA ........................53 6.1.12 ACMA ........................53 6.1.13 RoHS ........................53 6.1.14 Other Approvals ....................54 EMC and Environmental Type Tests ..............54 RUGGEDCOM RX1400 Installation Manual, 09/2019, C79000-G8976-1103-13...
  • Page 6: Preface

    However, deviations between the product and the documentation may exist. Siemens shall not be liable for any errors or omissions contained herein or for conse- quential damages in connection with the furnishing, performance, or use of this ma- terial.
  • Page 7: Training

    Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
  • Page 8: Contacting Siemens

    Preface Contacting Siemens • Ask questions or share knowledge with fellow Siemens customers and the support community Contacting Siemens Address Telephone E-mail Siemens AG Toll-free: 1 888 264 0006 ruggedcom.info.i-i Industry Sector Tel: +1 905 856 5288 [email protected] 300 Applewood Crescent...
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM RX1400 Installation Manual, 09/2019, C79000-G8976-1103-13...
  • Page 10: Introduction

    The RUGGEDCOM RX1400 is a multi-protocol intelligent node that combines Ethernet switch, routing and firewall functionality with various wide area connectivity options. The RUGGEDCOM RX1400 switch, with its rugged metal housing, is designed for DIN rail, panel or rack mounting.
  • Page 11: Description

    RF interfaces • R-SMA connectors for WLAN RF in- terface Description The RUGGEDCOM RX1400 features various ports, controls and indicator LEDs on the front panel for connecting, configuring and troubleshooting the device. Serial Ports Access Plate Port Status LEDs...
  • Page 12 RS232 Serial Console Port (DB9) ANT5 Port POWER LED ALARM LED CELL LED Figure 1.1 RUGGEDCOM RX1400 POWER LED Illuminates when power is being supplied to the device. ALARM LED Illuminates when an alarm condition exists. CELL LED Indicates when the cellular modem is connected to the network.
  • Page 13: Required Tools And Materials

    Introduction 1.3 Required Tools and Materials Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RX1400: Tool/Material Available For Pur- chase From Siemens WLAN, LTE and/or GPS antennas ü Antenna N-connect and/or SMA cables ü...
  • Page 14: Protection On Twisted-Pair Data Ports

    Siemens also does not recommend using copper Ethernet ports to interface with de- vices in the field across distances that could produce high levels of ground potential rise (i.e.
  • Page 15 1000Base-SX 10GBase-SR OM1 (62.5/125) — 1300 2000 — — OM2 (50/125) — 1300 2000 — — OM3 (50/125) 1500 — 1300 2000 — — OM4 (50/125) 3500 — 1300 2000 — — Laser optimized. RUGGEDCOM RX1400 Installation Manual, 09/2019, C79000-G8976-1103-13...
  • Page 16: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 17: General Procedure

    Inspect the package for damage before opening it. Visually inspect each item in the package for any physical damage. Verify all items are included. NOTICE If any item is missing or damaged, contact Siemens for assistance. RUGGEDCOM RX1400 Installation Manual, 09/2019, C79000-G8976-1103-13...
  • Page 18: Installing The Device In Hazardous Locations

    2.3 Installing the Device in Hazardous Locations Installing the Device in Hazardous Locations The RUGGEDCOM RX1400 is designed to comply with the safety standards for Class I, Division 2, Zone 2 hazardous locations where concentrations of flammable gases, va- pors or liquids may be present, as opposed to normal operating environments.
  • Page 19: Mounting The Device

    "Dimension Drawings (Page 39)". 2.4.1 Mounting the Device to a Rack For rack mount installations, the RUGGEDCOM RX1400 can be equipped with rack mount adapters pre-installed on the chassis. CAUTION Electrical/mechanical hazard – risk of damage to the device. Before installing the device in a rack, make sure of the following: •...
  • Page 20: Mounting The Device On A Din Rail

    2.4.2 Mounting the Device on a DIN Rail For DIN rail installations, the RUGGEDCOM RX1400 can be equipped with a DIN rail bracket pre-installed on the back of the chassis. The bracket allows the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
  • Page 21: Mounting The Device To A Panel

    2.4.3 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RX1400 can be equipped with panel adapters pre-installed on each side of the chassis. The adapters allow the device to be attached to a panel using screws.
  • Page 22: Connecting The Antennas

    Install the supplied screws to secure the adapters to the panel. Connecting the Antennas The RUGGEDCOM RX1400 can be connected to external antennas for access to wire- less networks. For increased signal coverage and improved performance, antennas are intended to be installed in a remote location separate from the RUGGEDCOM RX1400.
  • Page 23: Antenna Ports

    Installing the Device 2.5.1 Antenna Ports 2.5.1 Antenna Ports The RUGGEDCOM RX1400 features the following antenna ports:   Port Type Function ANT1 LTE SISO ANT2 ANT3 RP/SMA WLAN SISO ANT4 RP/SMA WLAN MIMO ANT5 LTE MIMO ANT1 Port ANT2 Port ANT3 Port...
  • Page 24 Directional 6GK5793-6DG00-0AA0 https://support.indus- T793-6DG try.siemens.com/cs/ww/en/- view/60509676 ANT793-6D- Omni-Di- 6GK5793-6DT00-0AA0 https://support.indus- rectional try.siemens.com/cs/ww/en/- view/60510334 ANT793-6MN Omni-Di- 6GK5793-6MN00-0AA6 https://support.indus- rectional try.siemens.com/cs/ww/en/- view/26228205 Directional 18.0 6GK5793-8DJ00-0AA0 https://support.indus- T793-8DJ try.siemens.com/cs/ww/en/- view/60509959 ANT793-8D- Directional 13.5 6GK5793-8DP00-0AA0 https://support.indus- try.siemens.com/cs/ww/en/- view/89534905 RUGGEDCOM RX1400 Installation Manual, 09/2019, C79000-G8976-1103-13...
  • Page 25: Connecting Lte Antennas

    Antennas must be placed at a distance of at least 35 cm (13.8 in) from all persons during normal operation. The antennas used for this product must not be located or operating in conjunction with any other antenna or transmitter, except in accor- dance with FCC multi-transmitter evaluation procedures. RUGGEDCOM RX1400 Installation Manual, 09/2019, C79000-G8976-1103-13...
  • Page 26 Tested in accordance with UL 50 and UL 497 NOTICE A Radio Frequency (RF) site survey is recommended prior to any installation to help determine the best location for the LTE antennas. For assistance, contact a Siemens Sales representative. NOTICE The cellular modem supports SISO (Single Input Single Output) and MIMO (Multiple Input Multiple Output) modes.
  • Page 27: Connecting A Gps Antenna

    For increased signal coverage and improved performance, the GPS antenna is intend- ed to be installed in a remote location separate from the RUGGEDCOM RX1400. The signals received from the GPS satellite network are at a frequency of 1575.42 MHz.
  • Page 28 NOTICE A site survey is recommended prior to any installation to help determine the best lo- cation for the GPS antenna. For assistance, contact a Siemens Sales representative. NOTICE Although it is impossible to protect the antenna from a direct lightning strike, the antenna and connected components can be protected from secondary effects through site selection and by installing protection devices.
  • Page 29: Connecting Wlan Antennas

    Installing the Device 2.5.5 Connecting WLAN Antennas If required, connect the optional lightning arrestor, line amplifier or bandpass fil- ter to the antenna. Drain Wire RUGGEDCOM RX1400 Shielded Coaxial Cable Lightning Protector, Line Amplifier or Bandpass Filter Ground Wire GPS Antenna Figure 2.7...
  • Page 30: Connecting The Failsafe Alarm Relay

    Control of the failsafe relay output is configurable through RUGGEDCOM RX1400. One common application for this relay is to signal an alarm if a power failure oc- curs. For more information, refer to the RUGGEDCOM RX1400 User Guide for the RUGGEDCOM RX1400.
  • Page 31: Connecting Power

    Common Normally Open Figure 2.9 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RX1400 supports a single integrated high AC/DC or low DC power supply. NOTICE Before installing the device, note the following: • An appropriately rated AC or DC circuit breaker must be installed.
  • Page 32 Connect the ground terminal on the power source to the chassis ground termi- nal on the device. RUGGEDCOM RX1400 Installation Manual, 09/2019, C79000-G8976-1103-13...
  • Page 33: Connecting Low Dc Power

    Connect the ground terminal on the power source to the chassis ground termi- nal on the device. RUGGEDCOM RX1400 Installation Manual, 09/2019, C79000-G8976-1103-13...
  • Page 34: Device Management

    This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RX1400 console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM RX1400 User Guide for the RUGGEDCOM RX1400.
  • Page 35: Configuring The Device

    RUGGEDCOM RX1400 User Guide associated with the installed software release. Installing the SIM Cards The RUGGEDCOM RX1400 supports dual micro-SIM cards for the LTE modem to pro- vide a fail-over mechanism should one of the SIM cards lose connectivity with the network.
  • Page 36: Inserting/Removing The Microsd Card

    Close the access panel and secure it with the two screws. Once the device is fully installed, activate the micro-SIM cards for the LTE mo- dem. For more information, refer to the RUGGEDCOM RX1400 User Guide for the RUGGEDCOM RX1400.
  • Page 37 MicroSD Card Access Plate Figure 3.3 Inserting/Removing a MicroSD Card Without touching the contacts on the card, insert or remove the microSD card. Install the access plate and finger-tighten the retention screw. Power up the device. RUGGEDCOM RX1400 Installation Manual, 09/2019, C79000-G8976-1103-13...
  • Page 38: Communication Ports

    Communication Ports The RUGGEDCOM RX1400 can be equipped with various types of communication ports to enhance its abilities and performance. Serial Ports Access Plate ANT1 Port Fast Ethernet Ports ANT2 Port SFP Transceiver Ports ANT3 Port ANT4 Port ANT5 Port Figure 4.1...
  • Page 39: Sfp Transceivers

    State Description Green (Solid) Link established Green (Blinking) Activity No link detected Compatible SFP Transceivers The following SFP transceivers are compatible with the RUGGEDCOM RX1400. For more information, including installation/removal instructions and ordering infor- RUGGEDCOM RX1400 Installation Manual, 09/2019, C79000-G8976-1103-13...
  • Page 40: Serial Ports

    1000 MM = Multi-Mode, SM = Single-Mode Serial Ports The RUGGEDCOM RX1400 supports two serial ports with female DB9 connectors, which can be run in RS-232, RS-485 or RS-422 mode. For technical specifications, re- fer to "Serial Port Specifications (Page 36)".
  • Page 41 The shield should be connected to earth ground at a single point to avoid loop currents. • The twisted pair should be terminated at each end of the chain. The following shows the recommended RS485 wiring. RUGGEDCOM RX1400 Installation Manual, 09/2019, C79000-G8976-1103-13...
  • Page 42 Communication Ports 4.3 Serial Ports 120Ω 10nF 120Ω 10nF RUGGEDCOM RX1400 Device Common (Isolated Ground) Negative Positive Shield to Earth (Connected At a Single Point) RS-485 Devices (32 Total) Figure 4.4 Recommended RS-485 Wiring RUGGEDCOM RX1400 Installation Manual, 09/2019, C79000-G8976-1103-13...
  • Page 43 Communication Ports 4.3 Serial Ports RUGGEDCOM RX1400 Installation Manual, 09/2019, C79000-G8976-1103-13...
  • Page 44: Technical Specifications

    Technical Specifications This chapter provides important technical specifications related to the device. Power Supply Specifications The RUGGEDCOM RX1400 includes one of the following internal power supplies: Maximum Pow- Power Supply Type Input Range Internal Fuse Rating er Consumption 88-264 VAC 98-300 VDC 3.15 A(T)
  • Page 45: Serial Port Specifications

    Auto-negotiating. Shielded or unshielded. Auto-crossover and auto-polarity. RMS 1 minute. Serial Port Specifications The RUGGEDCOM RX1400 supports two serial ports with female DB9 connectors. For more information about the serial ports, refer to "Serial Ports (Page 31)". Baud Rate 1200 to 230400 kbps...
  • Page 46 Band 8 AT&T 880-915 925-960 WCDMA 900 Europe Supported GSM Frequency Bands Band Frequencies (MHz) Transmit (Tx) Receive (Rx) GSM 850 824-849 869-894 EGSM 900 880-915 925-960 DCS 1800 1710-1785 1805-1880 PCS 1900 1850-1910 1930-1990 RUGGEDCOM RX1400 Installation Manual, 09/2019, C79000-G8976-1103-13...
  • Page 47: Gnss Specifications

    Any other than LHCP (Left-Hand Circular Polarized) is acceptable. Vertical linear polarization is sufficient. Gv and Gh are measured and averaged over -45 to 90° in elevation, and ± 180° in azimuth. WLAN Specifications Supported Standards IEEE 802.11a IEEE 802.11b IEEE 802.11g RUGGEDCOM RX1400 Installation Manual, 09/2019, C79000-G8976-1103-13...
  • Page 48: Operating Environment

    Host Interface 4-Bit SDIO Maximum EIRP < 200 mW at 5250 to 5350 MHz Operating Environment The RUGGEDCOM RX1400 is rated to operate under the following environmental conditions. Ambient Operating -40 to 85 °C (-40 to 185 °F) Temperature Ambient Storage Tem- -40 to 85°C (-40 to 185 °F)
  • Page 49 Technical Specifications 5.9 Dimension Drawings 88.0 120.0 130.1 Figure 5.1 Overall Dimensions 465.2 3 x 45° 482.0 418.0 Figure 5.2 Rack Mount Dimensions RUGGEDCOM RX1400 Installation Manual, 09/2019, C79000-G8976-1103-13...
  • Page 50 Technical Specifications 5.9 Dimension Drawings 142.1 Figure 5.3 Panel Mount Dimensions RUGGEDCOM RX1400 Installation Manual, 09/2019, C79000-G8976-1103-13...
  • Page 51 Technical Specifications 5.9 Dimension Drawings 129.6 139.7 Figure 5.4 Din Rail Mount Dimensions RUGGEDCOM RX1400 Installation Manual, 09/2019, C79000-G8976-1103-13...
  • Page 52: Certification

    Certification The RUGGEDCOM RX1400 device has been thoroughly tested to guarantee its confor- mance with recognized standards and has received approval from recognized regula- tory agencies. Approvals This section details the standards to which the RUGGEDCOM RX1400 complies. 6.1.1 This device meets the requirements of the following Canadian Standards Association (CSA) standards under certificate 16.70029035:...
  • Page 53: Csa/Sira

    • Ex nA nC IIC T4 Gc • Class I, Zone 2, AEx nA nC IIC T4 Gc A copy of the CSA Certificate of Compliance is available via Siemens Industry Online Support at https://support.industry.siemens.com/cs/ww/en/view/109744578. 6.1.2 CSA/Sira This device meets the requirements of the following CSA/Sira standards and is ap- proved for use in hazardous locations under certificates Sira 15ATEX4323X and IECEx CSA 16.0004X:...
  • Page 54: Tüv Süd

    National standard, with UL 60950-1) • UL 60950-1 Information Technology Equipment – Safety – Part 1: General Requirements) A copy of the TUV Certificate is available via Siemens Industry Online Support at https://support.industry.siemens.com/cs/ww/en/view/109476631. 6.1.4 European Union (EU) This device is declared by Siemens AG to comply with essential requirements and other relevant provisions of the following EU directives: •...
  • Page 55 The device is marked with a CE marking and notified body number, and can be used throughout the European community. 0682 A copy of the EU Declaration of Conformity is available via Siemens Industry Online Support at https://support.industry.siemens.com/cs/ww/en/view/109475609. RUGGEDCOM RX1400...
  • Page 56: Fcc

    Connect the device into an outlet on a circuit different from that to which the re- ceiver is connected • Contact Siemens Customer Support for assistance Notes specific to the FCC: NOTICE Changes or modifications not expressly approved by the party responsible for com- pliance could void the user's authority to operate this device.
  • Page 57: Fda/Cdrh

    ISO 9001:2015 Quality management systems – Requirements 6.1.8 ISED This device is declared by Siemens AG to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (B)/NMB-3 (B) Notices specific to ISED: Note This device is unable to transmit on the 5600 to 5650 MHz frequency band.
  • Page 58 NOTA Le dispositif fonctionnant dans la bande 5150-5250 MHz est réservé uniquement pour une utilisation à l'intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux. RUGGEDCOM RX1400 Installation Manual, 09/2019, C79000-G8976-1103-13...
  • Page 59 FCC. Ce périphérique contient l'ID IC: 2417C-MC7355 WWAN Modem cellulaire / PCS GSM / EDGE / CDMA / WCDMA / LTE. RUGGEDCOM RX1400 Installation Manual, 09/2019, C79000-G8976-1103-13...
  • Page 60: Rra

    Clause 3, Article 58-2 of the Radio Waves Act. As such, the device is marked with a KC symbol and can be used in the Republic of Korea (South Korea) as a Class B product in a commercial, industrial or business environment. MSIP-CMM-S14-RX1400 RUGGEDCOM RX1400 Installation Manual, 09/2019, C79000-G8976-1103-13...
  • Page 61: Anatel

    Section IX: Equipment Using Spectral Scatter Technology or other Digital Modula- tion Technologies Notices specific to ANATEL: NOTICE The RUGGEDCOM RX1400 is not certified for use on 2G, 3G or 4G LTE networks in Brazil. NOTICE In accordance with resolution No. 506, section IX, published by ANATEL (Agência Nacional de Telecomunicações), the maximum combined peak power of both anten-...
  • Page 62: Icasa

    6.1.13 RoHS This device is declared by Siemens AG to meet the requirements of the following Ro- HS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
  • Page 63: Other Approvals

    Industrial Environments • NEMA TS-2 Traffic Controller Assemblies with NTCIP Requirements EMC and Environmental Type Tests The RUGGEDCOM RX1400 has passed the following Electromagnetic Compatibility (EMC) and environmental tests. EMC Type Tests per IEC 61850-3 Test Description Test Levels...
  • Page 64 Signal Ports 5 kV DC Power Ports Siemens-specified severity levels EMC Immunity Type Tests per IEEE 1613 Note The RUGGEDCOM RX1400 meets Class 1 requirements for copper ports, which allows for temporary communication loss. Test Description Test Levels IEEE 1613...
  • Page 65 2 g @ 10-150 Hz IEC 60255-21-2 Shock 30 g @ 11 ms IEC 60255-21-3 Seismic Method A, Class 2 IEC 60068-1-14 Change of Temperature 5 Cycles (-40 to 85 °C or -40 to 185 °F) RUGGEDCOM RX1400 Installation Manual, 09/2019, C79000-G8976-1103-13...
  • Page 66 Further Information Siemens https://www.siemens.com Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...

Table of Contents