  • Page 3 ___________________ Safety information ___________________ General ___________________ SINAMICS Mechanical installation ___________________ Electrical installation SINAMICS G130 dV/dt filter compact plus Voltage ___________________ Peak Limiter Maintenance and servicing ___________________ Technical specifications Operating Instructions Firmware version V5.1 11/2017 A5E02590131A...
  • Page 4 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 5: Table Of Contents

    Table of contents Safety information ........................... 5 General safety instructions ....................... 5 Handling electrostatic sensitive devices (ESD) ..............10 General ..............................11 Mechanical installation .......................... 17 Electrical installation..........................23 Maintenance and servicing ........................29 Technical specifications ........................31 dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 11/2017, A5E02590131A...
  • Page 6 Table of contents dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 11/2017, A5E02590131A...
  • Page 7: Safety Information

    Safety information General safety instructions WARNING Electric shock and danger to life due to other energy sources Touching live components can result in death or serious injury. • Only work on electrical equipment if you are appropriately qualified. • Always observe the country-specific safety rules for all work. Generally, the following steps apply when establishing safety: 1.
  • Page 8 Safety information 1.1 General safety instructions WARNING Electric shock due to equipment damage Improper handling may cause damage to equipment. For damaged devices, hazardous voltages can be present at the enclosure or at exposed components; if touched, this can result in death or severe injury. •...
  • Page 9 • If you come closer than around 2 m to such components, switch off any radio devices or mobile phones. • Use the "SIEMENS Industry Online Support App" only on equipment that has already been switched off. WARNING Motor fire in the event of insulation overload There is a greater load on the motor insulation as result of a ground fault in an IT system.
  • Page 10 Safety information 1.1 General safety instructions WARNING Fire due to inadequate ventilation clearances Inadequate ventilation clearances can cause overheating of components with subsequent fire and smoke. This can cause severe injury or even death. This can also result in increased downtime and reduced service lives for devices/systems. •...
  • Page 11 Safety information 1.1 General safety instructions Note Important safety instructions for Safety Integrated functions If you want to use Safety Integrated functions, you must observe the safety instructions in the Safety Integrated manuals. dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 11/2017, A5E02590131A...
  • Page 12: Handling Electrostatic Sensitive Devices (Esd)

    Safety information 1.2 Handling electrostatic sensitive devices (ESD) Handling electrostatic sensitive devices (ESD) Electrostatic sensitive devices (ESD) are individual components, integrated circuits, modules or devices that may be damaged by either electric fields or electrostatic discharge. NOTICE Damage through electric fields or electrostatic discharge Electric fields or electrostatic discharge can cause malfunctions through damaged individual components, integrated circuits, modules or devices.
  • Page 13: General

    General Description The dv/dt filter compact plus Voltage Peak Limiter comprises two components: the dv/dt reactor and the voltage-limiting network (Voltage Peak Limiter), which cuts off the voltage peaks and feeds back the energy into the DC link. The dv/dt filter compact plus Voltage Peak Limiter is designed for use with motors for which the voltage strength of the insulation system is unknown or insufficient.
  • Page 14 Damage to the dv/dt filter compact by using components that have not been released When using components that have not been released, damage or malfunctions can occur at the devices or the system itself. • Only use a dv/dt filter compact that SIEMENS has released for operation with SINAMICS. NOTICE Damage to the dv/dt filter compact by exceeding the maximum output frequency The maximum permissible output frequency when using a dv/dt filter compact is 150 Hz.
  • Page 15 General NOTICE Damage to the dv/dt filter compact by exceeding the maximum pulse frequency The maximum permissible pulse frequency when using a dv/dt filter compact is 2.5 kHz or 4 kHz. The dv/dt filter compact can be damaged if the pulse frequency is exceeded. •...
  • Page 16 General Assignment of dv/dt filter compact plus Voltage Peak Limiter and Power Module Table 2- 1 Assignment of dv/dt filter compact plus Voltage Peak Limiter and Power Module Power Module Unit rating of the Power Module suitable dv/dt filter compact plus Voltage Peak Limiter Line voltage 3 AC 380 ...
  • Page 17 General Table 2- 2 Max. pulse frequency when a dv/dt filter compact plus Voltage Peak Limiter is used in units with a rated pulse frequency of 2 kHz Article no. of the Unit rating Output current for a Max. pulse frequency when a dv/dt filter com- Power Module [kW] pulse frequency of 2 kHz [A]...
  • Page 18 General Article no. of the Unit rating Output current for a Max. pulse frequency when a dv/dt filter com- Power Module [kW] pulse frequency of 1.25 kHz [A] pact plus Voltage Peak Limiter is used 6SL3310-... Line voltage 3 AC 660 V ... 690 V 1GH28-5AA3 2.5 kHz 1GH31-0AA3...
  • Page 19: Mechanical Installation

    Mechanical installation dV/dt filter compact plus Voltage Peak Limiter, type 1 Figure 3-1 Dimension drawing of dV/dt filter compact plus Voltage Peak Limiter, type 1 dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 11/2017, A5E02590131A...
  • Page 20 Mechanical installation dV/dt filter compact plus Voltage Peak Limiter, type 2 Figure 3-2 Dimension drawing of dV/dt filter compact plus Voltage Peak Limiter, type 2 dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 11/2017, A5E02590131A...
  • Page 21 Mechanical installation dV/dt filter compact plus Voltage Peak Limiter, type 3 Figure 3-3 Dimension drawing of dV/dt filter compact plus Voltage Peak Limiter, type 3 dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 11/2017, A5E02590131A...
  • Page 22 Mechanical installation dV/dt filter compact plus Voltage Peak Limiter, type 4 Figure 3-4 Dimension drawing for dV/dt filter compact plus Voltage Peak Limiter, Type 4: dV/dt reactor dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 11/2017, A5E02590131A...
  • Page 23 Mechanical installation Figure 3-5 Dimension drawing for dV/dt filter compact plus Voltage Peak Limiter, Type 4: Voltage Peak Limiter dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 11/2017, A5E02590131A...
  • Page 24 Mechanical installation Table 3- 1 Assignment of the dV/dt filter compact plus Voltage Peak Limiter to the dimension draw- ings dV/dt filter compact plus Voltage Peak Limiter Dimension drawing type Line voltage 380 V – 480 V 3 AC 6SL3000-2DE32-6EA0 Type 1 6SL3000-2DE35-0EA0 Type 2...
  • Page 25: Electrical Installation

    Electrical installation Interface overview Figure 4-1 Interface overview dv/dt filter compact plus Voltage Peak Limiter, type 1 dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 11/2017, A5E02590131A...
  • Page 26 Electrical installation Figure 4-2 Interface overview dv/dt filter compact plus Voltage Peak Limiter, type 2 Figure 4-3 Interface overview dv/dt filter compact plus Voltage Peak Limiter, type 3 dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 11/2017, A5E02590131A...
  • Page 27 Electrical installation Figure 4-4 Interface overview dv/dt filter compact plus Voltage Peak Limiter - dv/dt reactor Type 4 dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 11/2017, A5E02590131A...
  • Page 28 Electrical installation Figure 4-5 Interface overview dv/dt filter compact plus Voltage Peak Limiter - Voltage Peak Limiter, Type 4 Connection When connecting the dv/dt filter compact plus Voltage Peak Limiter, you must take into account the following conditions to ensure that it functions correctly: ●...
  • Page 29 Electrical installation Connection overview Figure 4-6 Connecting the dv/dt filter compact plus Voltage Peak Limiter - integrated unit Figure 4-7 Connecting the dv/dt filter compact plus Voltage Peak Limiter - separate components Cable cross-sections In a dv/dt filter with separate Voltage Peak Limiter (Type 4), the connections between dv/dt reactor and Voltage Peak Limiter are already installed on the Voltage Peak Limiter.
  • Page 30 Electrical installation Table 4- 2 Connection cable enclosed for connecting dv/dt reactor and Voltage Peak Limiter Voltage Peak Limiter Cross-section Lug for connecting 1U2 / 1V2 / 1W2 on the [mm²] dv/dt reactor Type 4 Cable type: 600 V, UL style 3271, operating temperature 125° C WARNING Fire and device damage as a result of ground fault/short-circuit Inadequate installation of the cables to the Power Module DC link can result in a ground...
  • Page 31: Maintenance And Servicing

    Maintenance and servicing Maintenance and servicing are not carried out for the compelte units (dV/dt filter compact plus Voltage Peak Limiter) and subcomponents (dV/dt reactor, Voltage Peak Limiter). In the case of an error, full replacement is necessary. dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 11/2017, A5E02590131A...
  • Page 32 Maintenance and servicing dV/dt filter compact plus Voltage Peak Limiter Operating Instructions, 11/2017, A5E02590131A...
  • Page 33: Technical Specifications

    Technical specifications General technical data Table 6- 1 General technical data Output frequency 0 ... 150 Hz Product standard EN 61800-5-1 Ambient conditions Storage Transport Operation Ambient temperature -25 ... +70 °C -25 ... +70 °C 0 ... +50 °C Relative air humidity (con- 5 ...
  • Page 34 Technical specifications Detailed technical data Table 6- 2 Technical data for the dv/dt filter compact plus Voltage Peak Limiter, 3 AC 380 V ... 480 V, part 1 Article number 6SL3000- 2DE32-6EA0 2DE35-0EA0 2DE38-4EA0 Suitable for Power Module 6SL3310- 1GE32-1AA3 1GE33-1AA3 1GE36-1AA3 1GE32-6AA3...
  • Page 35 Technical specifications Table 6- 3 Technical data for the dv/dt filter compact plus Voltage Peak Limiter, 3 AC 380 V ... 480 V, part 2 Article number 6SL3000- 2DE41-4EA0 Suitable for Power Module 6SL3310- 1GE41-0AA3 Unit rating of the Power Module 1405 thmax...
  • Page 36 Technical specifications Table 6- 4 Technical data for the dv/dt filter compact plus Voltage Peak Limiter, 3 AC 500 V ... 600 V, part 1 Article number 6SL3000- 2DG32-2EA0 2DG33-3EA0 2DG34-1EA0 Suitable for Power Module 6SL3310- 1GF31-8AA3 1GF32-6AA3 1GF34-1AA3 1GF32-2AA3 1GF33-3AA3 Unit rating of the Power Module...
  • Page 37 Technical specifications Table 6- 5 Technical data for the dv/dt filter compact plus Voltage Peak Limiter, 3 AC 500 V ... 600 V, part 2 Article number 6SL3000- 2DG35-8EA0 Suitable for Power Module 6SL3310- 1GF34-7AA3 1GF35-8AA3 Unit rating of the Power Module thmax Degree of protection...
  • Page 38 Technical specifications Table 6- 6 Technical data for the dv/dt filter compact plus Voltage Peak Limiter, 3 AC 500 V ... 600 V, part 3 Article number 6SL3000- 2DG38-1EA0 Suitable for Power Module 6SL3310- 1GF37-4AA3 1GF38-1AA3 Unit rating of the Power Module thmax Degree of protection...
  • Page 39 Technical specifications Table 6- 7 Technical data for the dv/dt filter compact plus Voltage Peak Limiter, 3 AC 660 V ... 690 V, part 1 Article number 6SL3000- 2DG31-0EA0 2DG31-5EA0 2DG32-2AA0 Suitable for Power Module 6SL3310- 1GH28-5AA3 1GH31-2AA3 1GH31-8AA3 1GH31-0AA3 1GH31-5AA3 1GH32-2AA3 Unit rating of the Power...
  • Page 40 Technical specifications Table 6- 8 Technical data for the dv/dt filter compact plus Voltage Peak Limiter, 3 AC 660 V ... 690 V, part 2 Article number 6SL3000- 2DG33-3AA0 2DG34-1EA0 2DG35-8EA0 Suitable for Power Module 6SL3310- 1GH32-6AA3 1GH34-1AA3 1GH34-7AA3 1GH33-3AA3 1GH35-8AA3 Unit rating of the Power Module...
  • Page 41 Technical specifications Table 6- 9 Technical data for the dv/dt filter compact plus Voltage Peak Limiter, 3 AC 660 V ... 690 V, part 3 Article number 6SL3000- 2DG38-1EA0 Suitable for Power Module 6SL3310- 1GH37-4AA3 1GH37-4AA3 Unit rating of the Power Module thmax Degree of protection...