Bosch REXROTH IndraDrive Applications Manual page 48

Hide thumbs Also See for REXROTH IndraDrive:
Table of Contents
46/97
Bosch Rexroth AG
Intelligent Error Reaction
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01
Rexroth IndraDrive Rexroth IndraMotion MLD Application Examples
As long as "bEnable" has been set, the drive moves in step 4 (Step 30)
with command velocity preset via the analog input and parameter
P‑0‑1374. When "bEnable" is reset, the error reaction is completed in Step
100 (see below).
Fig.6-13:
Step 30: Analog Velocity Input
6. Error reaction aborted/completed
In the fifth step (Step 100), "bActive" is set to the value of "bEnable",
"bTriggered" is reset, the axis is stopped, the enable signal of the drive is
removed and the drive PLC cedes control. When control is no longer in
the drive PLC, the program jumps back to the monitoring step (Step 0).
Step 40 has been prepared for further functionality and can be included
by the corresponding changes in the program. "Step 99" has been pre‐
pared for an additional error reaction, but it has not been programmed in
this example of application.
Fig.6-14:
Step 100: Error Reaction Aborted/Completed
DOK-INDRV*-MLD-APPLI**-AW02-EN-P