Page 1
ROUTING SWITCHER CONTROLLER BKPF-R70 INSTALLATION MANUAL 1st Edition Serial No. 10001 and Higher...
Page 2
! WARNING This manual is intended for qualified service personnel only. To reduce the risk of electric shock, fire or injury, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. Refer all servicing to qualified service personnel.
This section explains the precautions when connecting the BKPF-R70 to the system. 1-9. The Cautions of Power-ON This section explains the precautions in power on when the backup BKPF-R70 is installed in another PFV which installs the main BKPF-R70. 3 (E)
1-10. Setup This section explains the connection (between BKPF-R70 and a control terminal) and the sample screen when sets the devices connecting to the S-BUS line. 1-11. ISR (Interactive Status Reporting) This section explains the overview of the ISR system.
3. Insert the main board along the board guide rails. front panel. Fig1-02E 2. Remove the six screws and remove the board retainers. Fig1-01E Board guide rail PSW 3x6 Main board Component side Board retainers PSW 3x6 1-1 (E) BKPF-R70...
Page 8
When removing the main board, turn the board levers in the direction of the arrows 2, and pull out the board toward you. B 3x6 Connector panel Do not open the slot for air-cooled effect of the PFV-D300. Install the blank panel to a dead slot. 1-2 (E) BKPF-R70...
: 75 Z terminator Digital Video Interface Unit (PFV-xxx) REMOTE 3 Routing Switcher Controller Routing Switcher Controller BKPF-R70 BKPF-R70 (A) and (B) of the BKPF-R70 mean the main (A)/backup (B) switch setting on the board. Secondary station DVS-V6464B BKS-R3210 BKS-R3281...
1-3. Components 1-4. Location and Function of the Connectors 1-3. Components The BKPF-R70 is composed of the following items. . Main board (CPU-256 board) . Connector panel (CN-1515 board) . Operation Manual . Installation Manual . Slot number label . Data Backup Software (BZR-10) 1-4.
1-5. Connecting Connectors and Cables 1-5. Connecting Connectors and Cables If any cable is connected to the connectors on the connector panel when installing or servicing, use the connector or cable listed below or equivalent. BKPF-R70 Connector Panel Matching Connector/Cable Panel Indication Connector Connector SONY Part No.
ERROR Lights when an error is detected in a periodic self-diagnostics. This indicator goes out automatically when the board recovers from an error. The error is indicated on the 7-segment LED (IC27) by a double-digit error code. 1-7 (E) BKPF-R70...
Page 14
Selects the mode of the BKPF-R70 when the BKPF-R70 is connected to a personal computer. If selects ON, the BKPF-R70 is set to the ISR mode. If selects OFF, the BKPF-R70 is set to the setting terminal mode or data backup mode. ON (ISR):...
Page 15
Therefore, the cable break cannot be detected, but the response speed is faster than 312 kbps. OPEN (Upper) : 1250 kbps CLOSE (Lower) : 312 kbps (Factory setting) S4-5 to S4-7: Not used Factory setting : All CLOSE (Lower) 1-9 (E) BKPF-R70...
Page 16
Set COR2 to SBON if installs this board to a device which has the S-BUS remote connectors, such as PFV-D300. If installs two BKPF-R70 to PFV-D300 for the main board and backup board, set COR2 on the both boards to SBON. If the PFV-D300 is connected to the S-BUS line, the REMOTE 1 (S-BUS) connec- tor A of this board is connected to the S-BUS line without a cable and bridge.
If the IC link shorts out, be sure to replace it with the specified IC link described in the Maintenace Manual. . Prepare the T bridge and a coaxial cable and use them as follows for the dual-controller by using the main BKPF-R70 and the backup BKPF-R70. REMOTE1...
When each of two BKPF-R70 is used in different PFV unit, note the following. The caution of Power-ON . Turn on the power of the PFV in which a main BKPF-R70 (S8 is set to A side on CPU-256 board) is installed before the PFV in which a backup BKPF-R70 is installed.
Page 19
Y: DISPLAY TABLE DATA Z: SET UNIT DETECTABLE Ctrl _ X: QUIT SETUP MENU For the remainder of the setup procedure and the setting data backup (BZR-10 supplied with BKPF-R70 is used), refer to the installation manual of ROUTING SWITCHER SYSTEM. 1-13 (E)
This board has its own ISR interface function. The following messages are sent to the ISR system, permitting the operating status of the BKPF-R70 to be monitored without BKPF-500 ISR Interface Board. The ISR function is controlled by Sony application program software. For the program software, usage, installation, and operation of a personal computer in which this program software can be used, consult with your local Sony’s sales/service office.
Page 21
The material contained in this manual consists of information that is the property of Sony Corporation and is intended solely for use by the purchasers of the equipment described in this manual. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any...