Changed Setting Parameter By Load Cytropac Configuration - Bosch Rexroth Sytronix FcP 5020 Quick Start Manual

Frequency-controlled pump drive system
Hide thumbs Also See for Rexroth Sytronix FcP 5020:
Table of Contents
FcP 5020

8.7 Changed Setting Parameter by Load CytroPac Configuration

Code
Name
F1.20 CytroPac parameter initialization
Tab. 8-6: Auto-modified FcP 5020 parameter list in CytroPac initialization
When CytroPac parameter is initialized (via F1.20), all F group parameters and
some EFC parameters will be changed to CytronPac default settings according
to diverse CytroPac variants. The CytroPac default settings are different from
FcP default setting by following parameters shown in the list:
Code
E0.17 Direction control
E1.61 Broken wire protection
E2.15 Relay1 output selection
F1.03 Pressure command source
F1.11 Flow command source
F1.15 Motor type
F2.18 X3 input
F2.19 X4 input
F2.20 X5 input
F2.21 EX1 input
F2.22 EX2 input
F2.23 EX3 input
F2.24 EX4 input
F2.36 DO1 output
F2.37 EDO output
F3.00 p/Q parameter selection source
F4.00 Protection function control word
F4.36 Pump thermal protection speed
Tab. 8-7: Different parameter list between CytroPac and FcP default setting
* Not changing current value of this parameter.
DOK-RCON03-FCP5020****-QU02-EN-P
0: No selection
1: CytroPac basic
2: CytroPac advanced
3: CytroPac advanced + comm.
FcP default
Name
FcP 5020 Parameter List
Setting range
CytroPac
setting
basic
3
1
0
2
14
15
0
- *
0
-
1
0
0
-
0
-
0
-
0
-
0
-
0
-
0
-
1
0
0
-
0
-
0
8
500
0
Bosch Rexroth AG
Default
Min.
Attri.
0
-
Stop
CytroPac
CytroPac
advanced +
advanced
comm.
1
1
2
2
15
15
-
3
-
2
0
0
16
16
15
15
7
7
6
6
8
8
1
-
2
-
2
2
3
3
-
2
8
8
0
0
63/75
Table of Contents
loading