Page 3
___________________ Motor reactors Safety information ___________________ General ___________________ Mechanical installation SINAMICS ___________________ Electrical installation SINAMICS G130 ___________________ Motor reactors Technical specifications Operating Instructions Control version V4.5 03/2012 A5E00409660A...
Page 4
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Safety information Warnings WARNING Hazardous voltages are present when electrical equipment is in operation. Severe personal injury or substantial material damage may result if these warnings are not observed. Only qualified personnel are permitted to work on or around the equipment. This personnel must be thoroughly familiar with all the warnings and maintenance procedures described in these operating instructions.
The operating manual and machine documentation are written in different languages as specified in the delivery contracts. Note We recommend engaging the support and services of your local Siemens service center for all planning, installation, commissioning and maintenance work. Motor reactors...
General Description Motor reactors reduce the voltage load on the motor windings by reducing the voltage gradients at the motor terminals that occur during converter operation. At the same time, the capacitive charge/discharge currents that occur at the converter output when long motor cables are used are reduced.
Page 10
General Assignment of motor reactor and Power Module Table 2- 1 Assignment of motor reactor and Power Module Power Module Unit rating of the Power Module Suitable motor reactor Line voltage 380 – 480 V 3 AC 6SL3310-1GE32-1AAx 110 kW 6SL3000-2BE32-1AA0 6SL3310-1GE32-6AAx 132 kW...
Page 11
General Using a motor reactor and dv/dt filter to limit the voltage gradient and transients IGBT converter switching frequencies result in high voltage gradients (dv/dt) at the converter output. If long motor cables are used, this leads to an additional current load on the converter due to capacitive charge/discharge currents.
Page 12
General Motor reactors Operating Instructions, 03/2012, A5E00409660A...
Mechanical installation Dimension drawing Figure 3-1 Dimension drawing, motor reactor Motor reactors Operating Instructions, 03/2012, A5E00409660A...
Page 14
Mechanical installation Table 3- 1 Dimensions of motor reactor, 380 V – 480 V 3 AC, part 1 (all specifications in mm) 6SL3000- 2BE32-1AA0 2BE32-6AA0 2BE33-2AA0 2BE33-8AA0 Connection Type 1 Type 1 Type 1 Type 1 type 12.5 12.5 12.5 12.5 Lengths n1 and n2 correspond to the drill hole spacing Table 3- 2...
Page 15
Mechanical installation Table 3- 3 Dimensions of motor reactor, 500 V – 600 V 3 AC, part 1 (all specifications in mm) 6SL3000- 2AH31-8AA0 2AH32-4AA0 2AH32-6AA0 2AH33-6AA0 Connection Type 1 Type 1 Type 1 Type 1 type 12.5 12.5 12.5 12.5 Lengths n1 and n2 correspond to the drill hole spacing Table 3- 4...
Page 16
Mechanical installation Table 3- 5 Dimensions of motor reactor, 660 V – 690 V 3 AC, part 1 (all specifications in mm) 6SL3000- 2AH31-0AA0 2AH31-5AA0 2AH31-8AA0 2AH32-4AA0 2AH32-6AA0 Connection type Type 1 Type 1 Type 1 Type 1 Type 1 12.5 12.5 12.5...
Electrical installation Important safety precautions WARNING The devices are operated with high voltages. All connection procedures must be carried out when the cabinet is de-energized. All work on the device must be carried out by trained personnel only. Death, serious injury, or substantial material damage can result if these warnings are not taken into account.
Page 18
Electrical installation Connection When connecting the motor reactor, you must take into account the following conditions to ensure that it functions correctly: ● With analog control cables, connecting the shield at both ends can result in coupled-in noise. To prevent this, the shield must only be connected at one end on the Power Module.
Technical specifications General technical data Table 5- 1 General technical data Output frequency 0 ... 150 Hz Product standard EN 61800-5-1 Ambient conditions Storage Transport Operation Ambient temperature -25 ... +70 °C -25 ... +70 °C 0 ... +50 °C 95 % Relative air humidity 5 ...
Page 20
Technical specifications Detailed technical data Table 5- 2 Technical specifications of motor reactors 380 V – 480 V 3 AC, part 1 Order number 6SL3000- 2BE32-1AA0 2BE32-6AA0 2BE33-2AA0 2BE33-8AA0 Suitable for Power Module 6SL3310- 1GE32-1AAx 1GE32-6AAx 1GE33-1AAx 1GE33-8AAx Rated current Power loss - at 50 Hz 0.436...
Page 21
Technical specifications Table 5- 4 Technical specifications of motor reactors 380 V – 480 V 3 AC, part 3 Order number 6SL3000- 2AE41-0AA0 Suitable for Power Module 6SL3310- 1GE41-0AAx Rated current Power loss - at 50 Hz 0.939 - at 150 Hz 1.062 Connections - to the Power Module...
Page 22
Technical specifications Table 5- 6 Technical specifications of motor reactors 500 V – 600 V 3 AC, part 2 Order number 6SL3000- 2AH34-5AA0 2AH34-7AA0 2AH35-8AA0 2AH38-1AA0 Suitable for Power Module 6SL3310- 1GF34-1AA0x 1GF34-7AAx 1GF35-8AAx 1GF37-4AAx Rated current Power loss - at 50 Hz 0.481 0.631 0.705...
Page 23
Technical specifications Table 5- 8 Technical specifications of motor reactors 660 V – 690 V 3 AC, part 1 Order number 6SL3000- 2AH31-0AA0 2AH31-0AA0 2AH31-5AA0 2AH31-5AA0 Suitable for Power Module 6SL3310- 1GH28-5AAx 1GH31-0AAx 1GH31-2AAx 1GH31-5AAx Rated current Power loss - at 50 Hz 0.215 0.269 0.237...
Page 24
Technical specifications Table 5- 10 Technical specifications of motor reactors 660 V – 690 V 3 AC, part 3 Order number 6SL3000- 2AH34-5AA0 2AH34-7AA0 2AH35-8AA0 2AH38-1AA0 Suitable for Power Module 6SL3310- 1GH34-1AAx 1GH34-7AAx 1GH35-8AAx 1GH37-4AAx Rated current Power loss - at 50 Hz 0.481 0.631 0.705...