  • Page 1 Access Control AC5200 Quick Start Manual Siemens AB Security Products...
  • Page 2 Data and design subject to change without notice. / Supply subject to availability. © 2014 Copyright by Siemens AB Wir behalten uns alle Rechte an diesem Dokument und an dem in ihm dargestellten Gegenstand vor. Der Empfänger erkennt diese Rechte an und wird dieses Dokument nicht ohne unsere vorgängige schriftliche Ermächtigung ganz oder teilweise Dritten zugänglich machen oder...
  • Page 3: Table Of Contents

    AC5200 Mechanical .................. 8 Hardware Connection ................9 Basic Connection ..................9 Explanation of connectors ............... 10 Mounting the AC5200 ................11 Battery Installation................... 11 AC5200 Configuration ................12 Upgrading an Entro SR34i or SR35i ............12 Configuring Network Settings ..............13 Firmware Download ................
  • Page 4 Siemens AB Security Products 10.2013...
  • Page 5: Introduction

     the number of doors supported. The AC5200 can be used with either ACC or Entro devices. However ACC-X con- trollers can only be used with Entro devices, and are for migration sites. This Quick Start Manual outlines how to install and configure an AC5200 controller to work with SiPass integrated.
  • Page 6: Ac5200 Exterior

    Keypad cover. When the AC5200 is unlocked and the doors opened, this cover slides downward exposing a numeric keypad that can be used to set basic options for the AC5200. Keylock. To open the AC5200 cover the correct key must be used to unlock and provide mechanical access.
  • Page 7: Ac5200 Interior

    Introduction AC5200 Interior Fig. 2 AC5200 Interior Diagram Item Description Lock for use with supplied key. The middle of the front lid must be pressed downwards before the left and rid lid can be opened. B1, B2 Corner details that can be knocked out for hiding cable entry.
  • Page 8: Ac5200 Mechanical

    Introduction AC5200 Mechanical Fig. 3 AC5200 Mechanical Layout Siemens AB Security Products 10.2013...
  • Page 9: Hardware Connection

    This chapter explains how to connect up the power, communications and other things to the AC5200 hardware. Basic Connection The following section outlines the basic tasks required to get the AC5200 up and running. Power Connection The AC5200 requires a 12-24V power supply. Connect the power at terminals 1 and 2 of the AC5200.
  • Page 10: Explanation Of Connectors

    RJ45 Ethernet connections. Peer to Peer communication between controllers is also done via TCP/IP. Explanation of connectors The following table explains of each of the available connectors on the AC5200. Terminal Number Connector Label...
  • Page 11: Mounting The Ac5200

    To mount an AC5200: Remove the AC5200 from its carton and discard the packaging material. Place the AC5200 against the surface to which it is to be affixed and mark the location of the mounting holes. Select the appropriate drill bit according to the mounting surface / hole size and drill the holes in the locations marked (if required).
  • Page 12: Ac5200 Configuration

    AC5200 Configuration AC5200 Configuration This chapter outlines the configuration steps required to connect an AC5200 with SiPass integrated. Upgrading an Entro SR34i or SR35i This section only applies if you are upgrading Entro controllers in the field to ACC- X units.
  • Page 13: Configuring Network Settings

    Enter the host address with the keypad. – Press 5 to set the Port Address. This is the port the AC5200 uses to com- municate with SiPass integrated. By default it is 4343 Enter the port address with the keypad.
  • Page 14: Firmware Download

    Firmware downloads are done from the SiPass integrated software. This process is the same as downloading firmware for an ACC. Before you begin: The AC5200 must be created in the SiPass integrated database and be com-  municating To download firmware to the AC5200: Select System >...
  • Page 15: Menu Navigation

    Menu Navigation Menu Navigation This chapter explains the various menu navigation options. Fig. 4 AC5200 Keypad Item Description Display for Navigation and Messages Address Setting Escape Key (goes back to the previous menu) Backspace while entering (letters and digits) Confirmation button (some menus)
  • Page 17 2-3-1 Toggles telnet access Enabled Disabled 4) Reset to apply changes 1) Reset and apply changes 2-4-1 Resets the AC5200 and applies all network changes. 3) Compact Flash 1) Entro Firmware / Upgrade Firmware upgrade will commence and a status AC5200 Firmware will be displayed on the bottom line.
  • Page 18: Keyword Index

    Keyword index Keyword index AC5200, 5 Keylock, 6 ACC FLN, 9 Keypad cover, 6 ACC-X, 5 LCD Panel, 6 Change IP Settings, 17 COM A, 10 COM B, 10 Network Settings, 13, 17 Communication with devices, 9 Communication with SiPass integrated, 10...
  • Page 20 Issued by Siemens AB Infrastructure & Cities Security Products International Headquarters © 2014 Copyright by Siemens AB Englundavägen 7 SE-171 24 Solna Data and design subject to change without notice. Tel. +46 8 629 0300 Supply subject to availability. www.siemens.com/securityproducts A6V10208242 Document no.