Dell EqualLogic PS4210 Installation And Setup Manual

Dell EqualLogic PS4210 Installation And Setup Manual

Storage arrays
Hide thumbs Also See for EqualLogic PS4210:
Dell EqualLogic PS4210 Storage Arrays
Installation and Setup Guide
Table of Contents
loading

Summary of Contents for Dell EqualLogic PS4210

  • Page 1 Dell EqualLogic PS4210 Storage Arrays Installation and Setup Guide...
  • Page 3   Dell EqualLogic PS4210 Storage Arrays Installation and Setup Guide Version 1.0 Regulatory Model Series E03J and E04J...
  • Page 4 © Copyright 2014 Dell Inc. All rights reserved.  Dell™ and EqualLogic® are trademarks of Dell Inc. All trademarks and registered trademarks mentioned herein  are the property of their respective owners. Information in this document is subject to change without notice.  Reproduction of this material in any manner whatsoever without the written permission of Dell is strictly  forbidden. Published: October 2014 Part Number: M40C6-A00...
  • Page 5: Table Of Contents

    Table of Contents Preface 1 Understanding the Array Installation Procedure 2 Rack Mounting the Array Before You Begin Protecting Hardware Steps for Mounting an Array in a Rack 3 Connecting the Array Cables Network Requirements and Recommendations Minimum and Recommended Cable Configurations Connect and Secure the Power Cables Connect the Array to the Network Set Up a Serial Connection to the Array 4 Software Configuration Choose a Configuration Method Collect Configuration Information Start the Software Configuration Set the Member RAID Policy 5 Storage Allocation Create a Volume Connect a Computer to a Volume 6 Where to Go After Setting Up a Group Common Group Customization Tasks 7 Other Information You Might Need...
  • Page 6 Installation and Setup Guide Table of Contents...
  • Page 7: Preface

    Related Documentation For detailed information about   P S Series arrays, groups, volumes, array software, and host software:         1.  Log in to the Dell EqualLogic support site (eqlsupport.dell.com). 2.  Select Downloads. 3.  From the drop-down list, choose   P S Series Firmware. 4.  Under Recommended PS Series Firmware, select the required version. The link to the download page  appears. 5.  Click the Download page link. 6.  Scroll down to Documentation. Dell Online Services You can learn about Dell products and services by visiting dell.com (or the URL specified in any Dell product  information). To learn more about Dell EqualLogic products and new releases, visit the Dell EqualLogic Tech Center site:  delltechcenter.com/page/EqualLogic. Here you can also see articles, demos, online discussions, and more details  about the benefits of our product family. Technical Support and Customer Service Dell’s support service is available to answer your questions about PS Series SAN arrays. If you have an Express  Service Code, have it ready when you call. The code helps Dell’s automated-support telephone system direct ...
  • Page 8 Installation and Setup Guide Preface Contacting Dell Dell provides several online and telephone-based support and service options. Availability varies by country and  product, and some services might not be available in your area. To contact Dell EqualLogic Technical Support by phone, if you are located in the United States, call 800-945- 3355. For a listing of International Dell EqualLogic support numbers, visit dell.com/support/home. From this  website, select your country from the drop-down list in the upper left corner of the screen. If you do not have  access to an Internet connection, contact information is printed on your invoice, packing slip, bill, or Dell product  catalog. Use the following procedure to register for an EqualLogic customer support account, to log cases via the web,  and to obtain software updates, further documentation and resources.  1.  Visit eqlsupport.dell.com  or the Dell support URL specified in information provided with the Dell product. 2.  Select the required service. Click the   link, or select the Dell support service from the list of  Contact Us services provided. 3.  Choose your preferred method of contacting Dell support, such as e-mail or telephone. Warranty Information The PS4210 array warranty is included in the shipping box. For information about registering a warranty, visit  https://eqlsupport.dell.com/utility/form.aspx?source=warranty. Notes, Cautions, and Warnings Symbols A NOTE symbol indicates important information that helps you make better use of your hardware or software. A CAUTION symbol indicates potential damage to hardware or loss of data if instructions are not followed. A WARNING symbol indicates a potential for property damage, personal injury, or death. Further Information For  ...
  • Page 9: Understanding The Array Installation Procedure

    1 Understanding the Array Installation Procedure To set up your array and start using the iSCSI SAN array, follow these steps: 1.  Install the array in a rack. See Rack Mounting the Array on page 2.  Connect the array to power and the network. See Connect and Secure the Power Cables on page 11 and  Connect the Array to the Network on page 3.  Configure the PS Series software. First, initialize an array to make it accessible on the network. Then, either  create a group with the array as the first group member or add the array to an existing group. When you  expand a group, capacity and performance increase automatically. See Choose a Configuration Method on page 4. ...
  • Page 10 PS4210 Hardware Owner's Manual 1  Understanding the Array Installation Procedure...
  • Page 11: Rack Mounting The Array

    2 Rack Mounting the Array For proper operation, a PS Series storage array must be properly installed in a rack. This section  contains   g eneral electrostatic, safety, network, and installation information for PS Series arrays. After installing the array in a rack, connect the power and network cables, as described in  Chapter Before You Begin Before installing the array: •  Register for a Dell™ EqualLogic® Customer Support Account. If you do not have a  customer service support account, go to eqlsupport.dell.com and create one. •  Download and read the Release Notes from the Support Site. The PS Series Storage Arrays Release Notes contain the latest product information. •  Read the installation safety precautions. See Installation Safety Precautions on page Make sure the rack meets the rack requirements. See Rack Requirements on page •  •  Make sure the array and installation location meet the environmental requirements. See  Environmental Requirements on page • ...
  • Page 12: Protecting Hardware

    PS4210 Installation Guide 2  Rack Mounting the Array •  For the ReadyRails™ II rail kits, the distance between the outside surfaces of the front and  rear rack posts (the mounting surfaces) can range from 595 mm to 914 mm (23.4” to 36.0”)  for square-hole racks, 581 mm to 907 mm (22.9” to 35.7”) for round-hole racks, and 595 mm  to 929 mm (23.4” to 36.6”) for threaded-hole racks. •  The rack is secured to the floor for added stability. •  Load a rack with arrays from the bottom to the top.  •  There is at least 4.1 cm (1.6 inches) between the rack door and the front of the array to  accommodate the array front bezel.  •  The rack (with installed arrays) meets the safety requirements of UL 60950-1 and IEC  60950-1, available at                     ulstandardsinfonet.ul.com/scopes/scopes.asp?fn=60950-1.html. •  Mount the array in a horizontal orientation or you will void your array warranty and support  contract. Environmental Requirements The rack location must meet the following environmental requirements: •  The power source can supply a voltage range of 100V to 240V AC. • ...
  • Page 13 PS4210 Installation Guide 2  Rack Mounting the Array 3.  Connect the band to ground. You can either plug the banana connector into a matching  grounded receptacle, or attach it to the matching alligator clip and connect the clip to a  grounded device. Examples of an appropriate ground would be an ESD mat or the metal  frame of a grounded piece of equipment.  Shipping Box Contents and Required Hardware Make sure you have all the items supplied in the shipping box, described in Table 1. You must   provide additional hardware that is specific to your environment and not included in the shipping  box. See Table 2. Table 1: Shipping Box Contents Component Description •  Two Type 19 control modules •  Two power supply and cooling modules PS Series Array                                                 • ...
  • Page 14: Steps For Mounting An Array In A Rack

    PS4210 Installation Guide 2  Rack Mounting the Array Optional Hardware You can optionally use an uninterruptible power supply system (UPS) to provide a highly  available source of power to an array. Each UPS (not included) should be on a different circuit  and must provide the correct type of voltage for an adequate amount of time.  Steps for Mounting an Array in a Rack To mount an array in a rack, follow these steps: 1.  Determine where to place the mounting rails in the rack. 2.  Attach the mounting rails to the rack. 3.  Slide the chassis into the rack.  4.  Attach the chassis to the front of the mounting rails. 5.  Install the bezel.  These steps are described in detail in the following sections.  Determine Where to Place the Mounting Rails in the Rack Make sure there is enough space in the rack for the chassis. In a standard rack, a 2U chassis ...
  • Page 15 PS4210 Installation Guide 2  Rack Mounting the Array Figure 2: Installing the Array Into the Rack Figure 3 shows the front view of the 3.5-inch drive array. Figure 3: 3.5-Inch Drive Array - Front View (Without Bezel) Figure 4 shows the front view of the 2.5-inch drive array.  Figure 4: 2.5-Inch Drive Array - Front View (Without Bezel) With assistance, lift the array, keeping the array level, and slide it onto the mounting rails until  the array engages.  Attach the Array to the Mounting Rails Make sure the array captive fasteners on the front of the array line up with the threaded holes on ...
  • Page 16 PS4210 Installation Guide 2  Rack Mounting the Array Installing the Bezel The steps for installing the bezel are the same for all   a rray models:               1.  Hook the right end of the bezel onto the right side of the chassis. 2.  Swing the left end of the bezel toward the left side of the chassis. 3.  Press the bezel into place until the release latch closes. 4.  Using the key provided, lock the bezel and store the key in a safe place as shown in Figure  Figure 5: Installing the Bezel...
  • Page 17: Connecting The Array Cables

    Turn on power to the array. See Turning On the Array on page The following sections describe these steps in detail. After completing the steps, see Software Configuration on page Network Requirements and Recommendations The  minimum network configuration for a PS Series array consists of a connection between  Ethernet 0 on each control module and a computer connected to a network switch. To increase  performance and availability, configure multiple network interfaces on an array and connect  them to multiple switches. Network recommendations are described in Table 3. In addition, all the usual rules for proper  network configuration apply to PS Series arrays. For more information about network  requirements, see the Dell EqualLogic Configuration Guide on the Dell TechCenter website at                 en.community.dell.com/techcenter/storage/w/wiki/2639.equallogic-configuration-guide.aspx. General network configuration is beyond the scope of this manual. Table 3: Network Recommendations Recommendation Description Connect arrays and computers to a switched network and ensure that all  network connections between computers and arrays are 10GbE.  Use optical cables with optical SFP+ plug-in modules, or copper cables with  Switched 10GbE ...
  • Page 18: Minimum And Recommended Cable Configurations

    (available on some switches) that let the port immediately transition into STP  Use of spanning-tree  forwarding state upon link up. This functionality can reduce network  protocol interruptions that occur when devices restart, and   s hould   b e enabled only on  switch ports that connect end nodes.  You can use STP for a single-cable connection between switches and   t runking  for multicable connections between switches. To use DCB (Data Center Bridging), configure switches to use VLANs to  VLANs separate iSCSI SAN traffic from other network traffic. You must have VLANs enabled. Refer to the Dell EqualLogic Group Manager Administrator's Manual, and the Dell EqualLogic Group Manager CLI Reference Guide for more information about DCB. Minimum and Recommended Cable Configurations For a dual control module array, the recommended configuration is to connect network cables to  Ethernet 0 on both control modules, and connect each control module to a network switch.  For high performance and availability, distribute the connections across multiple network  switches.  The switches must be connected with interswitch links that have sufficient bandwidth to handle  the iSCSI traffic, or by stacking capability. Dell recommends using stacking configurations  wherever possible.
  • Page 19: Connect And Secure The Power Cables

    PS4210 Installation Guide 3  Connecting the Array Cables Figure 6: Recommended Network Configurations Connect and Secure the Power Cables Obtain the power cables that were shipped with the array. If the array was not shipped with  power cables, contact your PS Series support provider or reseller for power cable information. 1.  Make sure that the power switch is in the OFF (O) position before connecting the power  cables.  2.  Connect the power cables to the power supplies as shown in . 3.  Secure the power cables to the system: a. Secure the power cables firmly to the bracket next to the system power receptacle  using the provided hook-and-loop strap. b. Make sure the strap is tightly bound to the bracket anchor point (remove any slack). c. Bias the power cable toward the strap and wrap the strap tightly around the cable  against the shoulder of the power cable connector. 4.  Attach the power cables to a power source:...
  • Page 20: Connect The Array To The Network

    Do not turn on power to the array yet.  Figure 7: Connecting the AC Power Cables Connect the Array to the Network The PS4210 array model includes two Type 19 control modules. Each Type 19 control module  includes two 10Gbase-T ports and two 10Gbe SFP+   p orts. Of each pair, one is labeled Ethernet  0 and the other is labeled Ethernet 1. The control modules also include one 10Mb/100Mb port labeled Management. The management  port cannot carry iSCSI traffic. Use the management port only if you configure a management  network. See the Dell EqualLogic Group Manager Administrator's Manual for more information. Obtain the appropriate number of  copper or optical 10GbE network cables.  Note: Optical cables transmit data through pulses of light. It is very important to route all optical  cables with no more than a 4-inch bend radius at any point between the array and the switch. One functioning network connection is required for array operation. Multiple network  connections are recommended for performance and high availability. See Minimum and Recommended Cable Configurations on page 10 for additional information.
  • Page 21: Set Up A Serial Connection To The Array

    PS4210 Installation Guide 3  Connecting the Array Cables 1.  Find the power switch, located either below the power plug. See Figure 8. 2.  Press the power switch to the ON position. The power indicators will light. Batteries will start to charge and some hardware components will start to synchronize. LEDs  will indicate these normal activities. The battery backup unit installed in each controller is  shipped in a partially discharged state.  The first time the system is powered on, a boot delay of up to 30 minutes might be experienced  while the battery is charged to full capacity. The location of the   L EDs is shown in the following illustration. Table 4 provides LED  descriptions. Figure 8: AC Power Supply Switch and LEDs Table 4: Power Supply LED Descriptions Callout Description Power Supply status. This LED is lit (green) when the switch is on and the power  supply is providing power to the array. Error. This LED is lit (amber) if the power supply has a problem. Input Power. This LED is lit (green) as long as main power is connected to the power ...
  • Page 22 PS4210 Installation Guide 3  Connecting the Array Cables See Figure 9 (not to scale). The serial connection must have the following characteristics: •  9600 baud  •  One STOP bit •  No parity •  8 data bits •  No flow control Note: Keep the serial cable. You need the serial cable to manage the group, or a specific array,  if there is no network access. Figure 9: Connecting a Serial Cable to the Array...
  • Page 23 PS4210 Installation Guide 3  Connecting the Array Cables Serial Cable Pinout Information Figure 10 shows the pin locations on the DB9 connectors on the serial cable shipped with the  array, and Table 5 lists the pinout information for the cable. Figure 10: Serial Cable DB9 Connector - Pin Locations Table 5: DB9 to DB9 Pinout Information DB9-1 DB9-2 Function Function Receive Data Transmit Data Transmit Data Receive Data Data Terminal Ready Data Set Ready + Carrier Detect System Ground System Ground Data Set Ready + Carrier Detect...
  • Page 24 PS4210 Installation Guide 3  Connecting the Array Cables...
  • Page 25: Software Configuration

    After completing the software configuration, you can allocate storage and start using the iSCSI  SAN array. See Storage Allocation on page Choose a Configuration Method There are two methods for configuring the software. Choose one method: •  Use the Remote Setup wizard, either for Windows or Linux. For instructions about using the  Remote Setup wizard, see the Dell EqualLogic Host Integration Tools for Microsoft Installation and User’s Guide or the Dell EqualLogic Host Integration Tool for Linux Installation and User's Guide. •  Use the   utility. The   utility is an interactive, command line utility that prompts  setup setup for information about the array and group configuration. ...
  • Page 26: Start The Software Configuration

    PS4210 Installation Guide 4  Software Configuration Prompt Description Default gateway  Network address for the device used to connect subnets and forward  (optional) network traffic beyond the local network. A default gateway is needed only  if you want the array network interface to communicate outside the local  network (for example, to allow access to volumes from computers outside  the local network). The default gateway must be on the same subnet as the array network  interface. RAID policy RAID level and spare drive configuration for the array. The actual number  of RAID sets and spare drives depends on the number of drives in the array. •  RAID 6 – Distributed dual-parity sets.  •  RAID 10 – Striping on top of multiple RAID 1 (mirrored) sets.  •  RAID 50 – Striping on top of multiple RAID 5 (distributed-parity) sets.  Each RAID 5 set uses one drive's worth of space for parity.  •  RAID 5 – Distributed-parity sets. RAID 5—[Not Recommended] One  RAID 5 set, with one spare disk. RAID 5 is similar to RAID 50, with  more capacity (two additional disks) but lower availability and  performance. Note: To configure RAID 50 with drives larger than 3TB, or RAID 5  with drives of any size, you must use the Group Manager CLI. Table 7: Group Configuration Information Prompt Description Unique name that identifies the group (54 or fewer letters, numbers, or ...
  • Page 27 For help, enter a question mark (?) at a prompt. Welcome to Group Manager Copyright 2014 Dell Inc. It appears that the storage array has not been configured. Would you like to configure the array now? (y/n) [n] y...
  • Page 28 PS4210 Installation Guide 4  Software Configuration Searching to see if the group exists. This may take a few minutes. The group does not exist or currently cannot be reached. Make sure you have entered the correct group IP address and group name. Do you want to create a new group (yes | no) [yes]? yes Group Configuration group1...
  • Page 29: Set The Member Raid Policy

    PS4210 Installation Guide 4  Software Configuration Set the Member RAID Policy The storage space in a new group member (array) is not available until you configure a RAID  policy on the member.  A RAID policy consists of a RAID level and a spare disk configuration. When you select a  RAID policy, the member’s disks are automatically configured with the selected RAID level and  the appropriate number of spare disks.  If you used the Remote Setup wizard to create a group, the RAID policy for the first member is  set according to your RAID policy selection when configuring the software, and the storage is  ready to use. See Storage Allocation on page If you used the   utility to create or expand a group, or added the array to an existing group  setup with the Remote Setup wizard, you must set the RAID policy for the group member. Use either the Group Manager command line interface (CLI) or the graphical user interface  (GUI) to set the RAID policy. Using the CLI to Set the RAID Policy To use the Group Manager CLI to set the RAID policy for a new group member: 1.  Log in to the group, if you are not already logged in. (After the   utility completes, you  setup will still be logged in to the group.) Use one of the following methods to connect to the group: – ...
  • Page 30 PS4210 Installation Guide 4  Software Configuration 3.  Click   in the warning dialog box to open the Configure Member – General Settings dialog  box. 4.  Select the pool and click  . If prompted, confirm you want to assign the member to the  Next pool.  5.  Select the RAID policy on the Configure Member – RAID Configuration dialog box. 6.  (Optional) Select  .  Wait until the member storage initialization completes 7.  Click  Next 8.  Click   in the Configure Member – Summary dialog box. Finish Note: After initial RAID configuration, it takes a few minutes for   G roup Manager to display the  total usable capacity.   G roup Manager might show a smaller amount until the process is  complete.
  • Page 31: Storage Allocation

    Volume name  name, which is automatically generated for the volume. Access to a volume is  always through the target name. The reported size of the volume as seen by iSCSI initiators. The minimum volume  Volume size size is 15MB. Volume sizes are rounded up to the next multiple of 15MB. Optionally, you can set aside space for volume snapshots or configure a volume with thin  provisioning. However, thin provisioning is not appropriate for all storage environments. See the  Dell EqualLogic Group Manager Administrator's Guide for information about advanced volume  functionality.  Using the CLI to Create a Volume 1.  Log in to the group.  Use one of these methods to connect to the group: •  Serial connection to a member. See Set Up a Serial Connection to the Array on page •  Telnet or ssh connection to the group IP address. At the login prompt, enter the ...
  • Page 32 PS4210 Installation Guide 5  Storage Allocation •    ipaddress ip_address You can create a maximum of 16 access control records for a volume. The following example creates a 50GB volume and one access control record. Only a computer  with the specified initiator name will be able to access the volume. group1> volume create staff1 50GB group1> volume select staff1 access create initiator iqn.1991- 05.com.microsoft:WIN2008Server.company.com Using the GUI to Create a Volume To provide storage space to end users, you create standard volumes that users can then access  from host computers. Before you create a standard volume, you need to understand: •  Volume attributes and groupwide default settings of the group apply to a volume.  •  Volume security and access controls. In particular: – ...
  • Page 33 PS4210 Installation Guide 5  Storage Allocation Field Description Shortcut Key Alt+F If the group has volume folders, check this checkbox and  Create select a folder from the drop-down list to create the volume  volume in this folder. Folders help you organize large collections of  volumes into logical groups. Volumes can also be moved  folder into   f olders after they are created.  None If the group has multiple storage pools, select the storage  Storage pool you want to create the volume in. Click the radio  pool assign- button next to the pool's name to select it.   U nless otherwise  ment specified, the default storage pool is used.  Step 2: Space Field Description Shortcut Key A numeric value that specifies the size of the new volume.  Select appropriate units (MB, GB, or TB) from the drop-down ...
  • Page 34 PS4210 Installation Guide 5  Storage Allocation Field Description Shortcut Key Estimated This table estimates how the currently proposed volume size  changes in and snapshot settings affect the existing space in the  None storage pool designated storage pool. default Step 3: Configure iSCSI Access Field Description Shortcut Key Allows you to set the access controls for the volume. Select  What kind the radio button for the type of access you want: •  Alt+P of access •  Alt+L Table 9 type do you • ...
  • Page 35: Connect A Computer To A Volume

    PS4210 Installation Guide 5  Storage Allocation Field Description Shortcut Key Click New to define a new access policy or policy group. None From either the Available list or the Selected list, select an  None Edit access policy or policy group and click Edit to change it.  Step 4: Sector Size Field Description Shortcut Key You can create volumes that use   e ither 512-byte or 4KB  sectors. The sector size of a volume has no dependency on the  sector size of the physical drives in the array.   T he default  volume setting of 512 bytes is almost always optimal, even if  the physical drives use 4KB sectors. 512 bytes: Alt+5 If you create a volume that uses 4KB sectors,   f irst verify that  Sector Size 4KB: Alt+4 your operating system supports 4KB sectors. Refer to the ...
  • Page 36 PS4210 Installation Guide 5  Storage Allocation 1.  Install and configure an iSCSI initiator on the computer. Hardware and software initiators  are available from different vendors. Configure your initiator using the instructions provided  by the vendor. Note: Dell recommends that you visit the Technical Support website to obtain important  information about using initiators to access PS Series group volumes. 2.  Make sure that the computer matches one of the volume’s access control records. To display  the records for a volume: –  Using the CLI, enter the following command: volume select volume_name access show –  Using the GUI, expand   in the far-left panel, select the volume name, and click  Volumes the   tab. Access If necessary, use the CLI or the GUI to create an access control record that the computer  will match.  3.  To display the iSCSI target name for the volume: –  Using the CLI, enter the following command:  volume select volume_name show – ...
  • Page 37: Where To Go After Setting Up A Group

    After setting up a group, you can customize the group in order to more effectively manage your  storage environment. You can also begin to use the full set of product features. The following  documentation and additional products are included in the purchase of your array and are  available at any time. •  The Hardware Owner's Manual provides basic storage array information, maintenance  information, and troubleshooting information for your PS Series storage array hardware. •  The Dell EqualLogic Group Manager Administrator's Guide provides details about  configuring and using the PS Series firmware that is installed on each array. It includes  information about storage concepts and how to use the Group Manager GUI to manage a  group. •  The Dell EqualLogic Group Manger CLI Reference Guide describes how to use the Group  Manager CLI to manage a group and individual arrays. •  The Manual Transfer Utility supports off-network replication of volume data. •  In a VMware® environment, you can use the Dell EqualLogic Virtual Storage Manager  (VSM) for VMware to manage snapshots and replicas on the PS Series group that can  restore individual virtual machines or the whole VMware environment. •  You can use the Dell EqualLogic Storage Replication Adapter for VMware Site Recovery  Manager® (SRM), which allows SRM to understand and recognize PS Series replicas for  full SRM integration. •  The Dell EqualLogic Multipathing Extension Module (MEM) provides enhancements to the ...
  • Page 38 PS4210 Installation Guide 6  Where to Go After Setting Up a Group Task Description such as firmware upgrades. Accounts can be configured to be authenticated through the PS Series  group, RADIUS, or by using LDAP or Active Directory authentication. To be informed of significant events in a timely manner, set up email  Set up event notification or syslog notification. To monitor traps from the group, you can use SNMP. In addition, you  Configure SNMP need to configure SNMP to use the Manual Transfer Utility and other  third-party monitoring tools.  To automate iSCSI target discovery, you can configure the group to use  Configure iSNS an iSNS server. You can use CHAP to restrict computer access to volumes. Both  Configure CHAP accounts initiator and target CHAP authentication are supported. Group time is based on the clock on the first member, which is set at  Modify the date, time, or  the factory. The default time zone is EST. You can also configure the  time zone or configure NTP group to use an NTP server. Although a one-member group is fully functional, adding more arrays  Add a member to the group expands capacity, increases network bandwidth, and improves overall  group performance, with no disruption to data availability. With multi-member groups, you can create multiple pools and assign  Create pools members and volumes to the pools for a tiered storage solution.
  • Page 39: Other Information You Might Need

    7 Other Information You Might Need See the safety and regulatory information that shipped with your system. Warranty information  might be included within this document or as a separate document.  •  The rack documentation included with your rack solution describes how to install your  system into a rack. •  The Hardware Owner's Manual provides information about system features and describes  how to troubleshoot the system and install or replace system components. This document is  available online at eqlsupport.dell.com. NOM Information (Mexico Only) The   i nformation in this section is provided on the device described in this document in  compliance with the requirements of the official Mexican standards (NOM):   AC Power Supply NOM Information for Mexico Dell México S.A. de C.V. Paseo de la Reforma 2620 - 11° Piso Importer Col. Lomas Altas 11950 México, D.F. Supply voltage: 100–240 VAC Model number: E03J Frequency: 50/60 Hz Current consumption: 8.6A Supply voltage: 100–240 VAC...
  • Page 40 PS4210 Installation Guide 7  Other Information You Might Need Power Supplies Under typical line conditions and over the entire system ambient  operating range, the inrush current might reach 55A per power supply for  10 ms or less.   Physical Height 2U: 8.68 cm (3.41 inches) 8.68 cm (3.41 inches) Width 44.63 cm (17.57 inches) Depth PS4210 E (3.5-inch drives): 57.5 cm (22.6 inches) PS4210 X, XV (2.5-inch drives) 54.1 cm (21.3 inches) Weight  PS4210X, XV (2.5-inch drives), S, XS: 24.1 kg (53 lb) (fully loaded array) PS4210E (3.5-inch drives): 44.45 kg (98 lb)   Available Hard Drive Power (Per Slot) Supported hard  For 2.5-inch drives: drive power •  Up to 1.2 A at +5V  consumption ...
  • Page 41 PS4210 Installation Guide 7  Other Information You Might Need Environmental level •  Active mode: 7.4 bels, A-Weighted sound power level, LwA-UL as  Acoustics measured per ISO 7779 and declared per ISO 9296...
  • Page 42 PS4210 Installation Guide 7  Other Information You Might Need...
  • Page 43: Index

    Index Gigabit Ethernet recommendation group access control records accessing volumes from a computer  28 creating  24 advanced tasks  29 access controls creating  17 setting up with CLI  23 customizing after setup  29 accounts expanding  17 configuring after setup  29 IP address  18 array logging in to CLI  21 choosing where to mount  6 logging in to GUI  21 initializing  17 name  18 mounting in rack  6 network address  17 setting RAID policy  21 RAID policy  21 software configuration  17 hardware requirements  5 battery supplied  5 charging time  13 Host Integration Tools bezel description  20 installing  8 initiator (iSCSI)
  • Page 44 Index: netmask – volumes netmask safety precautions member setting  17 installation  3 network serial cable array IP address  17 characteristics  15 configuring multiple interfaces  29 connecting  13 group IP address  18 pin locations  15 improving performance  9 pinout information  15 setup utility recommendations  9 requirements  9 configuring the software  19 network cables description  17 network interfaces requirements  17 shipping box contents configuring  17 NTP server snapshots configuring  30 reserving space  23 SNMP configuring  30 software configuration methods  17...
  • Page 45 Index: warranty – warranty naming  23 reported size  23 snapshot space  23 target name for  28 thin provisioning settings  23 warranty...
  • Page 48 Gill Sans MT 9pt Printed in www.dell.com | support.dell.com 4.250” Sample BarCode.pdf...

Table of Contents