e-terrapowercom
Revision:
Document Date:
v2 Modem Installation Manual
1.8
June 14
, 2018
th
Table of Contents
loading

Summary of Contents for GE e-terrapowercom

  • Page 1 Modem Installation Manual Revision: Document Date: June 14 , 2018...
  • Page 2 “ESCA” and “HABITAT” are registered trademarks of Grid Solutions, a GE and Alstom joint venture. “e-terra” is a trademark and/or service mark of E-Terra, LLC, licensed for use by GE. Other product and company names in these materials may be trademarks or registered trademarks of other companies, and are the property of their respective owners.
  • Page 3: Table Of Contents

    Contents 1. Technical Specifications ..................6 2. Safety Precautions ....................8 2.1 Symbols ........................8 2.2 General Safety ......................8 2.3 Electrical Safety ......................8 3. Preparation Procedure ..................9 4. Hardware Description ..................10 4.1 Device Overview ..................... 10 4.2 Dimensions ......................
  • Page 4 Who Should Use This Document This document is suitable for field engineers with basic knowledge of Broadband Power Line Communications systems. For More Information For network design and software configuration, please refer to the e-terrapowercom Operation Manual. Proprietary – See Copyright Page...
  • Page 5 ANNEX - Filter configuration may-15 Heat related safety revision feb-15 GE format + annex revision (F1 & F3 inversion + serial port) feb-15 1 & 2 position inversion for filter switch may-18 ANNEX (p28) - Correction on Serial port jumper configuration...
  • Page 6: Technical Specifications

    IEC 60721-3-3: 3K5 / 3M4 Maximum range: -20°C to +65 °C Humidity: 5% to 95% non-condensing Altitude < 2000 m Pollution degree 2 IEC 61000-6-2:2005 IEC 61000-6-4:2006 IEC 61000-6-5:2001 ANSI C37.90.1/2/3 General Safety EN 60950 Proprietary – See Copyright Page e-terrapowercom v2 Installation Manual...
  • Page 7 -30 dBm / Hz (Long Range mode) -37 dBm / Hz (10 MHz mode) -40 dBm / Hz (20 MHz mode) -42 dBm / Hz (30 MHz mode) Ethernet SELV input/output Serial SELV input/output Proprietary – See Copyright Page e-terrapowercom v2 Installation Manual...
  • Page 8: Safety Precautions

    All cables must be installed and properly fixed at a safe distance from any energized parts of the electrical environment WARNING: All recommendations included in this section shall be strictly followed. Any consequence of misuse or mishandling of the device will be user’s legal responsibility Proprietary – See Copyright Page e-terrapowercom v2 Installation Manual...
  • Page 9: Preparation Procedure

    Connectors (modem side) AC input IEC320-C7 connector DC input Plug, 2 pins, 5mm pitch Ethernet RJ-45 BPL signal Plug, 3 pins, 5 mm pitch Serial Plug, 6 pins, 3,5 mm pitch Proprietary – See Copyright Page e-terrapowercom v2 Installation Manual...
  • Page 10: Hardware Description

    4. Hardware Description 4.1 Device Overview Front view Top View Bottom view Proprietary – See Copyright Page e-terrapowercom v2 Installation Manual...
  • Page 11 Exploded view with connectors, except RJ45 and AC Proprietary – See Copyright Page e-terrapowercom v2 Installation Manual...
  • Page 12: Dimensions

    The device must be installed in indoor environments or protected cubicles. The location must be protected against water, high temperatures and shocks. Please refer to supported environmental conditions in §1. The device can be mounted on a standard DIN rail (EN50022) using the back-side’s clip. Proprietary – See Copyright Page e-terrapowercom v2 Installation Manual...
  • Page 13: Mounting Procedure

    WARNING: to avoid any risk of electrical shock, the modem shall be disconnected to any power source during mounting procedure. Place the device over the DIN rail with the upper lip of the clip laying on the rail. Push the modem until the clip is locked Proprietary – See Copyright Page e-terrapowercom v2 Installation Manual...
  • Page 14: Removal Procedure

    WARNING: to avoid any risk of electrical shock, the modem shall be disconnected to any power source during removal procedure. Pull the latch down to release the modem from the rail Flip the bottom side of the modem and pull it away from the DIN rail Proprietary – See Copyright Page e-terrapowercom v2 Installation Manual...
  • Page 15: Interfaces

    The device shall be connected to an IEC standard appliance inlet protected by a 30 mA differential circuit breaker. The IEC standard plug for AC supply is located on the bottom side of the modem. Proprietary – See Copyright Page e-terrapowercom v2 Installation Manual...
  • Page 16: Dc Power Supply

    The device can be powered using a DC source in the voltage range specified in §1. The two pins connector is located on the bottom side of the modem It is recommended to secure the DC supply by screwing the connector flanges Proprietary – See Copyright Page e-terrapowercom v2 Installation Manual...
  • Page 17: Bpl Signal Interface

    Warning: positions 1 and 2 have been inverted on earlier production batches (those without the danger sign on BPL port). In this document, please refer to the picture above and consider position 1 as front position and position 2 as rear. Proprietary – See Copyright Page e-terrapowercom v2 Installation Manual...
  • Page 18: Splitter / Combiner

    Using simultaneously BPL 1 & 2 can result in higher impedance mismatch between the modem and the coupling systems. When impedances shown by coupling systems at BPL 1 & 2 are unbalanced, the signal transmission is also unbalanced. Proprietary – See Copyright Page e-terrapowercom v2 Installation Manual...
  • Page 19: Bpl Ports

    BPL signal is routed to PIN ‘+’ and ‘-‘ of the front side connectors. When using a shielded twisted pair, connect the shield to GND. It is recommanded to secure connector’s position using its screw flanges. Proprietary – See Copyright Page e-terrapowercom v2 Installation Manual...
  • Page 20: Ethernet Ports

    4 Ethernet ports are available on the front panel. All ports are connected to the same Ethernet bridge. Every RJ45 support auto-sensing and auto-negotiation feature for the following modes: 10 Mb Half Duplex 10 Mb Full Duplex 100 Mb Half Duplex 100 Mb Full Duplex Proprietary – See Copyright Page e-terrapowercom v2 Installation Manual...
  • Page 21: Serial Port

    A serial port is located on the top panel. Depending on product code, a device may support RS232 or RS485 protocol. The corresponding PINOUT for each case is given in the following table: RS-232 RS-485 3.3V Proprietary – See Copyright Page e-terrapowercom v2 Installation Manual...
  • Page 22: Connection To Mv Couplers

    6. Connection to MV Couplers In a usual installation, one coupler is attached to the e-terrapowercom BPL modem, using the proper connector and a shielded twisted pair. The coupler can be capacitive or inductive (please refer to the Coupler’s manual) The maximum recommended length for the twisted pair is 10 meters.
  • Page 23 For single coupling, use any of the the BPL ports and set the splitter switch to position 1. For double coupling, use both connectors and set splitter switch to position 2. Proprietary – See Copyright Page e-terrapowercom v2 Installation Manual...
  • Page 24: Leds Status

    Transmitting data on RS232/485 BPL Sync Not configured, no signal available Blinking Not configured, signal detected ON (REP) Configured, synchronized ON (HE) Configured, active Power status Power status OK Blinking, OFF Power failure Proprietary – See Copyright Page e-terrapowercom v2 Installation Manual...
  • Page 25: Maintenance & Troubleshooting

    Check the configuration of the modem and its neighbors is valid, especially regarding authentication. WARNING: if the problem persists, do not try to repair the modem yourself. Send it to a local GE representative for laboratory inspection. Proprietary – See Copyright Page...
  • Page 26: Annex - Filter And Serial Configuration

    Selectable filter feature requires a pre-configuration of the mother board. Pre-configuration procedure Open the box by removing all screws depicted below Remove the cover Proprietary – See Copyright Page e-terrapowercom v2 Installation Manual...
  • Page 27 Locate filter bank jumpers JP100 and JP101 on both side of the filter component. J100 J101 Place the jumpers according to the required filter combination (refer to table below and §5.3.2) Proprietary – See Copyright Page e-terrapowercom v2 Installation Manual...
  • Page 28 Top: RS232 Middle: RS485 Bottom: Off (as shown on picture) Put the board back on its original position on the chassis. Mount the cover and attach it using the original screws. Proprietary – See Copyright Page e-terrapowercom v2 Installation Manual...
  • Page 29 Warning: positions 1 and 2 have been inverted on earlier production batches. In this document, please refer to the picture given in §5.2.1 and consider position 1 as front position and position 2 as rear. Proprietary – See Copyright Page e-terrapowercom v2 Installation Manual...
  • Page 30 J2 + J4 + J9 + J10 Position 2  F1 Position 1  F1 J1 + J6 + J10 Position 2  F2 Position 1  F4 J8 + J11 + J10 Position 2  F3 Proprietary – See Copyright Page e-terrapowercom v2 Installation Manual...