Thank you for choosing this Mitsubishi inverter base unit.
This Installation Guideline provides handling information and precautions for use of this product. Incorrect
handling might cause an unexpected fault. Before using this product, always read this Installation Guideline
carefully to use this product correctly.
In addition, carefully read the Instruction Manual (Startup) enclosed with the separate control circuit board. Do not
use this product until you have a full knowledge of the product, safety information, and instructions.
CONTENTS
1. Introduction ........................................................ 2
2. Outline ................................................................ 2
3. Product Check .................................................... 3
800
4. Setting Up ........................................................... 8
Table of Contents
loading

Summary of Contents for Mitsubishi Electric 800 Series

  • Page 1: Table Of Contents

    INVERTER FR-AF800 INSTALLATION GUIDELINE FR-AF820-01540 to 04750 FR-AF840-00770 to 06830 FR-AF842-07700 to 12120 FR-AF860-00680 to 04420 FR-AF862-05450 to 08500 Thank you for choosing this Mitsubishi inverter base unit. This Installation Guideline provides handling information and precautions for use of this product. Incorrect handling might cause an unexpected fault.
  • Page 2: Please Forward This Installation Guideline To The End User

    Introduction Thank you for choosing this Mitsubishi Inverter base unit. This Installation Guideline explains how to set up an inverter base unit and a separately sold control circuit board. Read this Installation Guideline carefully to use this product correctly. Please forward this Installation Guideline to the end user. Outline The FR-AF800 is a base unit of the inverter.
  • Page 3: Product Check

    Product Check Base unit Symbol Voltage class Symbol Structure, functionality Symbol Description 200 V class Standard model 00770 to 12120 Inverter SLD rated current (A) 400 V class Separated converter type 600 V class F R - AF 8 2 0 - 00770 - 60 Circuit board Symbol coating...
  • Page 4: Control Circuit Board

    Control circuit board accessory Compatible base unit Symbol Description Symbol Voltage class FR-CA80 FR-CF80 Control unit for CA80 01540 to 03160 01540 to 04750 FR-A800 00770 to 01800 00770 to 12120 Control unit for CF80 00680, 01080 00680 to 08500 FR-F800 03800, 04750 02160 to 12120...
  • Page 5 control circuit board 1 Control circuit terminal block 1 Sticker .....1 FR-CA80-[]-[]-60 FR-CF80-[]-[]-60 FR-CA80-[]-E[]-60 FR-CF80-[]-E[]-60 Cable ...... 1 Mounting screw (M3 × 6mm) Earth plate.....1  ......2(3  Earth cable ... 1 Instruction Manual .....1 CD......1     For the FR-CA80-[]-E[]-[] and the FR-CF80-[]-E[]-[], three mounting screws are supplied.
  • Page 6  Combination of the inverter and the Instruction Manual The Instruction Manual and CD related to the inverter model in combination with the base unit and the control circuit board are shown below. Product Check...
  • Page 7 POINT POINT • If a combination of the base unit and control circuit board is not correct, an inverter fault (E.PE2) occurs, disabling the inverter operation. Product Check...
  • Page 8: Setting Up

    Setting Up Removal of a base unit front cover (lower side) When the mounting screws are removed, the front cover (lower side) can be removed. With the front cover (lower side) removed, wiring of the main circuit terminals can be performed.
  • Page 9 Installing a control circuit board on a base unit Install the control circuit board to the base unit. Remove a sponge for protecting the connector pin of the control circuit terminals. Base unit Control circuit board Install the control circuit board according to the following steps. Insert carefully not to bend the connector pin.
  • Page 10 Fix it with Fix it with Fix it with the screws. the screws. the screws. Fix it to the base unit with the supplied mounting screws. Slide in the control terminal block unit from the bottom and connect it with the control circuit board.
  • Page 11 Insert the cable side connector until these hooks become level. Connect the cable to the connector of the control circuit board and the connector on the upper right of the base unit. Route the cable through this hook. For the FR-CA80/CF80-[]-E[] control circuit board, install the earth plate. Fasten Fasten Fasten...
  • Page 12 Reinstallation of a base unit front covers Fasten Fasten Fasten Fasten Fasten Fasten Insert the upper hooks of the front cover (upper side) into the sockets of the inverter. Securely install the front cover (upper side) to the inverter by fixing the hooks on the sides of the cover into place.
  • Page 13: Sticker

    Applying a logo sticker Apply a sticker provided with the control circuit board on the base unit as shown below. FR-CA80 -[]-[]-60 , FR-CF80 -[]-[]-60 FR-CA80-[]-E[]-60, FR-CF80-[]-E[]-60 Completed When set-up is completed, it can be used as the FR-A800 or FR-F800. Instruction Manual Refer to the provided with the control circuit board for details of...
  • Page 14: Operation Check For The Safety Stop Function

    Operation check for the safety stop function After completing the work for "4. Setting up", be sure to perform the self-diagnostic test of the safety stop function and operation check. If the operation check is not performed, the safety stop function may not operate properly.
  • Page 15 Matrix of safety related signals Input Output Operation panel indication Input Internal safety terminal terminal   power circuit status So(SO) E.SAF   Not displayed Not displayed ー ー ー Normal Not displayed Not displayed  Normal Displayed Displayed ...
  • Page 16 WARRANTY When using this product, make sure to understand the warranty described below. 1. Warranty period and coverage We will repair any failure or defect (hereinafter referred to as "failure") in our FA equipment (hereinafter referred to as the "Product") arisen during warranty period at no charge due to causes for which we are responsible through the distributor from which you purchased the Product or our service provider.
  • Page 17 3. Service in overseas Our regional FA Center in overseas countries will accept the repair work of the Product; however, the terms and conditions of the repair work may differ depending on each FA Center. Please ask your local FA center for details.
  • Page 18 Restricted Use of Hazardous Substances in Electronic and Electrical Products The mark of restricted use of hazardous substances in electronic and electrical products is applied to the product as follows based on the “Management Methods for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products”...
  • Page 19 REVISIONS *The manual number is given on the bottom left of the back cover. Print Date Revision Manual Number Oct. 2016 IB(NA)-0600687ENG-A First edition...
  • Page 20 HEADQUARTERS EUROPEAN EUROPEAN EUROPEAN REPRESENTATIVES REPRESENTATIVES REPRESENTATIVES MITSUBISHI ELECTRIC EUROPE EUROPE B.V. GEVA AUSTRIA MITSUBISHI ELECTRIC IRELAND Beijer Electronics AB SWEDEN German Branch Wiener Straße 89 EUROPE B.V.-Irish Branch Box 426 Mitsubishi-Electric-Platz 1, A-2500 Baden Westgate Business Park S-20123 Malmö...

Table of Contents