Siemens CCMX1315-LP Configuration Manual

1/3” 1.3 megapixel ccd colour ip camera

Quick Links

CCMx1315-LP
1/3" 1.3 Megapixel
CCD Colour IP Camera
Configuration Manual
Building Technologies
Fire Safety & Security Products
Table of Contents
loading

Summary of Contents for Siemens CCMX1315-LP

  • Page 1 CCMx1315-LP 1/3” 1.3 Megapixel CCD Colour IP Camera Configuration Manual Building Technologies Fire Safety & Security Products...
  • Page 2 Trademarks CCMx1315-LP is a trademark of Fire & Security Products GmbH & Co. oHG. Microsoft is a registered trademark and Windows a trademark of Microsoft Corporation. All other products or company names referred to explicitly in this manual are mentioned only for purposes of identification or description and may be trademarks or registered trademarks of their respective owners.
  • Page 3: Table Of Contents

    7.3.1 7.3.2 7.3.3 7.3.4 7.4.1 7.4.2 7.4.3 7.4.4 7.4.5 Siemens Building Technologies Fire Safety & Security Products Safety ...6 Target readers...6 General safety precautions ...6 Transport...6 Installation ...6 Cleaning ...7 Meaning of the signal words ...7 Meaning of the hazard symbols ...7 EU directives ...8...
  • Page 4 7.9.2 7.9.3 7.10 7.10.1 7.10.2 7.10.3 7.10.4 7.10.5 7.10.6 7.11 7.12 Siemens Building Technologies Fire Safety & Security Products Record...37 FTP recording ...37 SD recording ...40 Emailing recording ...42 NAS recording ...44 Audio ...46 Date/Time...47 Access protection...48 Administrator ...49 User list ...49 Firewall ...50...
  • Page 5 Siemens Building Technologies Fire Safety & Security Products 01.2009...
  • Page 6: Safety

    Radio interference with other devices in the environment When handling modules that are susceptible to electrostatic discharge, please observe the ESD guidelines. Siemens Building Technologies Fire Safety & Security Products Qualification Activity...
  • Page 7: Cleaning

    IMPORTANT Meaning of the hazard symbols The nature of the hazard is indicated by icons. Tips and information Siemens Building Technologies Fire Safety & Security Products Type of risk Imminent danger of death or severe bodily injury Possible danger of death or severe bodily harm There is a risk of minor to medium injuries or damage to property.
  • Page 8: Eu Directives

    EU directives EU directives The product complies with the requirements of the following EU directives. The EU declaration of conformity is available from: Siemens Building Technologies Fire & Security Products GmbH & Co. oHG 76181 Karlsruhe Germany European Directive 2004/108/EC “Electromagnetic Compatibility”...
  • Page 9: Specifications

    Alarm connector Power connector RS485 Mechanism Dimensions (LxWxH) Weight Siemens Building Technologies Fire Safety & Security Products Description 1/3” progressive ExviewHAD CCD, 1.3 Megapixels 1280 (H) x 960 (V) Motion JPEG/ MPEG4 SXGA: 1280 x 960 at 12.5 fps max.
  • Page 10: Ordering Data

    Utilities CD Installation instruction (English, German, French, Spanish, Italian) SD card (2 GB) Hexagonal wrench Torx wrench T6 Lens connector Siemens Building Technologies Fire Safety & Security Products Part no. Designation S54561-C80-A1 1/3” 1.3 MP Colour IP Camera 12 V DC / 24 V AC, 50 Hz or PoE S54561-C80-A2 1/3”...
  • Page 11: Camera Part And Connector Definition

    RJ45 Ethernet connector Audio input (φ3.5mm) Audio out (φ3.5mm) SW for default SW for reset Power indicator DC12V/AC24V power terminal Siemens Building Technologies Fire Safety & Security Products Camera part definition Digital I/O terminal IP/TV selection SD card slot SD card protection 1/4”...
  • Page 12: Connector Pin Definition

    5.2.5 IP/TV switch 5.2.6 Default/reset buttons DEFAULT RESET Siemens Building Technologies Fire Safety & Security Products 1. External alarm input-2 2. Becoming BW/CL enforced input when the Digital Input Mode is set to BW Mode in the Configuration- Alarm page...
  • Page 13: Installing The Camera

    Do not drop the power adapter or subject it to strong impact. Do not use the power adapter in hot and humid places. Siemens Building Technologies Fire Safety & Security Products Be sure to use only a suitable power adapter. Using a wrong power adapter may cause the camera to malfunction, heat up, or catch fire.
  • Page 14: Concept Of The Network Camera

    Camera search application "IpFinder" Install this application from the CD-ROM supplied as an accessory. (Double-click "ipfinder_Setup.exe" in the CD-ROM and install the application in accordance with the instructions on the screen) Siemens Building Technologies Fire Safety & Security Products Ethernet SIEMENS...
  • Page 15: Connecting The Camera And Personal Computer Via Network

    It is also recommended to set the computer's IP address from the router's DHCP server. For more information, read your computer's user's guide. Siemens Building Technologies Fire Safety & Security Products Entering an IP address manually (factory default) Obtaining an IP address automatically from the DHCP server Installing the camera 01.2009...
  • Page 16 It takes about 10 seconds to activate the camera. If a port number other than "80" is set, designate the port number by suffixing it after ":" as in http://192.168.0.10:88. Siemens Building Technologies Fire Safety & Security Products Connect LAN cable and turn the power on.
  • Page 17: Using The Camera Search Application "Ipfinder

    Using "IpFinder (Web-Cam IP Manager Version 3.0)" to search for a camera NOTE Set the personal computer to "Administrator authorization" when using "IpFinder." Siemens Building Technologies Fire Safety & Security Products Insert the CD in the CD-ROM drive of the personal computer.
  • Page 18: Using The Camera Search Application "Web Cam Ip Manager

    SSDP multicast messages sent by the Web-Cam IP Manager to the network segment where the device is located. SSDP (Simple Service Discovery Protocol / network protocol) Siemens Building Technologies Fire Safety & Security Products Start the Web-Cam IP Manager by loading IP Manager.exe. This application is found on the CD included with delivery.
  • Page 19: Log-In Screen

    Enable cookies Set "Browser setting when proxy server is used" when a proxy server is used. Change "security" in Internet options as follows: Siemens Building Technologies Fire Safety & Security Products Open the Internet Explorer. Enter the default IP address: 192.168.0.10.
  • Page 20 ● Using the network cameras via a proxy server sometimes takes a long time till images are displayed after log-in or reduces the frame rate of delivered images. Siemens Building Technologies Fire Safety & Security Products Click "Level customize".
  • Page 21 Play Language PTZ operating panel Image stream 1 & stream 2 Siemens Building Technologies Fire Safety & Security Products Choose "Pop-up Blocker" on the tool menu. Choose "Always Allow Pop-ups from This Site...". this function enables OSD setting including title name, date and time...
  • Page 22: Configuration

    – – Frame Rate: seven frame rates – 1, 2, 3, 5, 10, 12, 25 – are available for selection. Siemens Building Technologies Fire Safety & Security Products Low compression: This setting produces highest image quality. The file size increases.
  • Page 23 RTSP Port Number – specify the port number you would like to use for RTSP protocol, default is 554 VIDEO Port Number - specify the port number you would like to use for video streaming, default is 5000 Siemens Building Technologies Fire Safety & Security Products Configuration 01.2009...
  • Page 24 For example: rtsp://192.168.0.194:554/livestream. Regarding default value of RTSP port, it’s based on which stream you select. VCL media player Siemens Building Technologies Fire Safety & Security Products Select Open then click the Network tab. Click RTSP then fill in web address rtsp://:/livestream...
  • Page 25 Using Quicktime For example: rtsp://192.168.0.194:554/livestream. Regarding default value of RTSP port, it’s based on which stream you select. Quicktime livestream Siemens Building Technologies Fire Safety & Security Products Select Open URL . Fill in rtsp://:/livestream Click OK. Configuration 01.2009...
  • Page 26: Network Settings

    Stream1-Stream2, cropping1-5: UPnP AUDIO output Siemens Building Technologies Fire Safety & Security Products Input your camera name here. The default name is “nwcam05”. The IP address is automatically obtained when you select ON; otherwise, select OFF to manually set up the network setting.
  • Page 27: Ddns Settings

    Max. Simultaneous Connections box. Click Save to save your setting. NOTE The purpose is to download or delete the directories/files in SD memory card. Siemens Building Technologies Fire Safety & Security Products OFF: The network camera will stream images at the maximum frame rate allowed by the network.
  • Page 28: Image Parameters

    Basic items such as the size and quality of delivered images of the camera can be set here. The settings will not be reflected unless the Save button is clicked. Siemens Building Technologies Fire Safety & Security Products Configure auto black-and-white function. Auto B/W is the function to gain sensitivity by turning to B/W automatically at dark environment.
  • Page 29 Sharpness Gamma White Balance Iris Adjustment Siemens Building Technologies Fire Safety & Security Products Four types of specific application conditions such as Indoor, outdoor, tunnel and casino can be selected for a quick and easy setup. 19 steps of offset level from -9 to +9 are available to adjust the internal reference brightness level.
  • Page 30: Camera-Mask Zone Settings

    Picture Picture Flip Picture Mirror 7.3.2 Camera-mask zone settings Siemens Building Technologies Fire Safety & Security Products 3. Lower 2/3 (Area designation) Back Light Compensation Set image to be upside or down. Select ON or OFF to activate or deactivate the flip function.
  • Page 31: Camera Cropping Settings

    The mask function is not supported when the cropping function is on. 7.3.3 Camera cropping settings Siemens Building Technologies Fire Safety & Security Products Tick the "ENABLE" checkbox and fill in the name, then click “Set Cropping Area” to start cropping setting.
  • Page 32 Up to 5 cropping areas can be set on the screen. The MPEG4 function is not supported when the cropping function is on. Siemens Building Technologies Fire Safety & Security Products Select a type of cropping from VGA, QVGA, 4CIF, 2CIF, CIF, QCIF, and Free Size at the bottom of the screen.
  • Page 33: Camera Osd Settings

    Two alarm digital input terminals AL1, AL2 are located on the rear panel. Before using the alarm function certain parameters need to be defined. Siemens Building Technologies Fire Safety & Security Products Configuration 01.2009...
  • Page 34: External Digital Input 1

    – enforced BW – is added, which will switch the camera to monochrome mode if a trigger signal is received. Siemens Building Technologies Fire Safety & Security Products The following functions will be enabled if “ Alarm Input” is set to “ON”...
  • Page 35: Motion Detection Settings

    Pre-recorded voice files with extension .wav that have been uploaded to SD memory card in advance can be selected as voice alarm message. Max. 4 kinds of audio source can be selected. Siemens Building Technologies Fire Safety & Security Products Set to ON: open motion detection function.
  • Page 36: Alarm Output

    SD card from your PC. There are 4 audio events available for upload. You can select in the appropriate menu which audio event is to be played with which event (Motion or Alarm input 1). Siemens Building Technologies Fire Safety & Security Products B/W: when the camera changes to monochrome Event: Once alarm input1 or alarm input 2 or motion is triggered, the alarm out will be triggered immediately as well.
  • Page 37: Record

    Monday to Sunday. Recording by Alarm Configure "Alarm input setting" first. Then select the recording format: – Siemens Building Technologies Fire Safety & Security Products Record Source: choose JPEG or MPEG4 format Configuration 01.2009...
  • Page 38 FTP server name: Input a server name or address. Login ID: Limited to users who have authority to access the server. Password: Input the registered password associated with the login ID. Siemens Building Technologies Fire Safety & Security Products Recording Frame Set the number of images to be recorded immediately after an alarm occurs.
  • Page 39 Accumulation Cycle: Set a time interval in seconds for images to be stored. (Time interval: 1, 2, 5, 10, 15, 30, 60 or 120 seconds) Overwrite: Overwrite when SD card reaches the maximum capacity and start with oldest stored images. Siemens Building Technologies Fire Safety & Security Products Configuration 01.2009...
  • Page 40: Sd Recording

    Scheduled Recording Determine the recording condition: STOP, all day, schedule 1 or schedule 2 from the recording schedule table for all days from Monday to Sunday. Siemens Building Technologies Fire Safety & Security Products Configure the individual settings as described below.
  • Page 41 Setting the overwrite mode to ON deletes files, beginning with old files. If important data is to be saved, set the Overwrite mode to OFF. Siemens Building Technologies Fire Safety & Security Products Record source: choose JPEG or MPEG4 format Recording frame Set the number of images to be recorded immediately after an alarm occurs.
  • Page 42: Emailing Recording

    Recording Schedule – select intended recording days on the recording schedule table. Recording cycle – Set a time interval for schedule recording – 30, 60, 120, 240, 600, 1200, 1800, 3600s can be selected. Siemens Building Technologies Fire Safety & Security Products 01.2009...
  • Page 43 Setup E-mail condition to Motion. All the other settings are similar to alarm. Mail to Address List You can send e-mails to multiple users when schedule, alarm in, or motion detection occurred. Siemens Building Technologies Fire Safety & Security Products Configuration 01.2009...
  • Page 44: Nas Recording

    Configuration 7.5.4 NAS recording This is a method to store data on a network-based storage device. Siemens Building Technologies Fire Safety & Security Products Choose record condition: Select the condition for NAS recording: recording by Schedule, Alarm or Motion to trigger the recording session.
  • Page 45 All the other settings are same as recording by alarm as above. NOTE Make sure all NAS devices are ready on the network before activating this function. Siemens Building Technologies Fire Safety & Security Products Record source: choose JPEG or MPEG4 format Recording frame Set the number of images to be recorded immediately after an alarm occurs.
  • Page 46: Audio

    – – NOTE Please use an external audio amplifier or loudspeaker with integrated amplifier for increased volume. Siemens Building Technologies Fire Safety & Security Products HIGH: Increased audio input level. LOW: Reduced audio input level. HIGH: Increased audio output level.
  • Page 47: Date/Time

    – Daylight Select ON to active Daylight-saving function if you are in Daylight-saving time zone (effective for NTP mode only). Siemens Building Technologies Fire Safety & Security Products Manual: Input the date and time to set up system time. NTP: You can also enable Network Time Protocol (NTP) by NTP server.
  • Page 48: Access Protection

    Configuration Access protection Siemens Building Technologies Fire Safety & Security Products 01.2009...
  • Page 49: Administrator

    Advanced user can see the live picture and do basic operation like PTZ control, and Preset setting from buttons on bottom of screen. User can see the live picture only, no authorization to do any operation. Siemens Building Technologies Fire Safety & Security Products Configuration...
  • Page 50: Firewall

    Denied: all the IP addresses enabled in the list shall be rejected by the firewall. 7.9.2 Forbidden Ports All the ports listed and enabled will be forbidden to pass the firewall. Siemens Building Technologies Fire Safety & Security Products 01.2009...
  • Page 51: Forbidden Protocol

    Never disconnect power and LAN cable during the firmware update process. Rebooting the camera after firmware update may take approx. 15 minutes. SIGNALWORT Siemens Building Technologies Fire Safety & Security Products The power supply to the camera must not be interrupted during the SW update.
  • Page 52: 7.10.3 Configuration

    Network camera reboot – Click the Reboot button and a the confirmation message "This will reboot the camera. Are you sure?" will be displayed. Click "OK" to reboot the network camera. Siemens Building Technologies Fire Safety & Security Products 01.2009...
  • Page 53: 7.10.4 Backfocus

    If a temperature notification interval has been set an e-mail notice will be delivered continuously. If the notification interval is set to "0", the e- mail notice will be delivered only once. Siemens Building Technologies Fire Safety & Security Products Configuration...
  • Page 54: Log

    You can click the icons on the bottom to see and process the logs, such as: “display all logs”, “display system logs”, “display user logs”…. 7.12 Notice This dialog shows all licenses information for the camera. Information Siemens Building Technologies Fire Safety & Security Products 01.2009...
  • Page 55: Utility Program Application

    It can make an alarm out event. After you finish audio record, please perform alarm audio setting. Perform audio recording in the following sequence Siemens Building Technologies Fire Safety & Security Products included in the delivery.
  • Page 56: Firmware Update Setup

    Firmware update setup This application is found on the network cameras synchronously. Perform firmware update in the following sequence Siemens Building Technologies Fire Safety & Security Products included in the delivery. You can update multi- Execute firmware update setup first.
  • Page 57: Maintenance

    Maintenance Defective modules should be sent to the nearest Siemens office to be forwarded to the service centre. Disposal All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities.
  • Page 58: Keyword Index

    E-mail Server (SMTP) 42 Emailing recording 42 Ethernet 9 EU directives 8 EV Adjustment 29 Event Log 54 Siemens Building Technologies Fire Safety & Security Products Factory Default 52 Firewall 50 Firmware update setup 56 Forbidden Ports 50 Forbidden Protocol 51...
  • Page 59 Resolution 22 RJ45 Ethernet connector 11 RTSP Port Number 23 Safety information 6 Safety precautions 6 SD Card slot 11 Siemens Building Technologies Fire Safety & Security Products SD recording 40 Secondary DNS 26 Sharpness 29 Shutter Speed 29 Signal words 7...
  • Page 60 Issued by Siemens Building Technologies Fire & Security Products GmbH & Co. oHG D-76181 Karlsruhe www.buildingtechnologies.siemens.com/ Document no. A6V10236123 Edition 15.01.2009 © 2009 Copyright by Siemens Building Technologies Data and design subject to change without notice. Supply subject to availability.

Table of Contents