Samsung SSA-P400 User Manual

Access control panel
Hide thumbs Also See for SSA-P400:
Access Control Panel

user manual

imagine
Thank you for purchasing this Samsung product.
To receive more complete service,
please visit our website.
www.samsungsecurity.com
the possibilities
SSA-P400
SSA-P400T
SSA-P401
SSA-P401T
Table of Contents
loading

Summary of Contents for Samsung SSA-P400

  • Page 1: User Manual

    Access Control Panel user manual imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please visit our website. www.samsungsecurity.com SSA-P400 SSA-P400T SSA-P401 SSA-P401T...
  • Page 2: Safety Information

    If this product fails to operate normally, contact the nearest service center. Never disassemble or modify this product in any way. (SAMSUNG is not liable for problems caused by unauthorized modifi cations or attempted repair.) . When cleaning, do not spray water directly onto parts of the product. Doing so may cause fi re or electric shock.
  • Page 3: Important Safety Instructions

    Keep out of direct sunlight and heat radiation sources. It may cause fi re. Install it in a place with good ventilation. Avoid aiming the controller directly towards extremely bright objects such as sun. Apparatus shall not be exposed to dripping or splashing and no objects fi lled with liquids, such as vases, shall be placed on the apparatus.
  • Page 4: Table Of Contents

    contents PRODUCT INTRODUCTION INSTALLATION AND EXTERNAL CONNECTION INITIALIZATION TROUBLESHOOTING PRODUCT SPECIFICATIONS contents Features What’s included Cable Selection Connecting the termination resistor and diode Earth-grounding the communication cables Power, Reader, and I/O Connection Communication Line Connection System Initialization Board ID Setting Troubleshooting Product Specifi...
  • Page 5: Features

    Installed and managed inside the security zone for preventing the risk of damage, SSA-P400 (P401) can implement a high level security access control system with multiple control options, best fi t for access control and time &...
  • Page 6: Holiday Setup

    product introduction Input Port Format Setup 15 input ports are provided by default. For these ports, you can specify if the format of the incoming signal is blocked (NO) or connected (NC) in normal operation. This setting will make all ports operate same regardless of the output status of the input device.
  • Page 7: What's Included

    WHAT’S INCLUDED Check if the following items are included in the product package. Main Unit Quick Guide Diode (x12) CD Manual (UF4004, 1N4001~4007) English7...
  • Page 8 product introduction Main Board Board ID Setup The address number specifi ed by the address setup switch should match that of the Switch host computer as it is used for communications with the host computer. I/O Board Connection Communication ports to connect to the I/O board, which include Input #8 through Input Port #15 and Output #8 through Output #15.
  • Page 9 RJ-45 Connect the LAN cable for TCP/IP communications. RS-232 One RS-232 communication port is provided. Used to exclusively connect to a PC in a Communication local area. Port RS-422 One RS-422 communication port is provided. Communication You can establish up to 32 multi-drop communications. Port Power Connection DC +12V is used for the power source.
  • Page 10 product introduction I/O Board Fixing Hole Power LED Indicator Main Board Connection Port Output (Relay #5) Port Output (Relay #6) Port Output (Relay #7) Port Output (Relay #8) Port product introduction Used to fi x the main board to the I/O board using screws. The red indicator turns on in the normal power supply condition.
  • Page 11 INPUT #8 Input port #8. Input port #9. INPUT #9 INPUT #10 Input port #10. INPUT #11 Input port #11. INPUT #12 Input port #12. INPUT #13 Input port #13. INPUT #14 Input port #14. INPUT #15 Input port #15. Output (Relay #9) Port Output port #9 (FORM-C).
  • Page 12: Cable Selection

    product introduction CABLE SELECTION RS-232 HOST P.C. RS-422 RF Reader Exit Button/Sensor Input Item Power (DC12V) DC Power Device Reader (power and data) External reader Device Door Contact Sensor Exit Button Sensor Input Input Device Door Lock Alarm Device Lock (Alarm) Device RS-232 Cable Converter...
  • Page 13: Connecting The Termination Resistor And Diode

    If you do not connect a bypass diode to the relay, the voltage surge will cause damage to the electric circuit of the controller. To reduce this surge, it is recommended to connect a bypass diode to the relay. SSA-P400(401) RS-485 RS-485...
  • Page 14: Earth-Grounding The Communication Cables

    installation and external connection EARTH-GROUNDING THE COMMUNICATION CABLES We recommend you to use a proper grounding system for the communication cables. The best grounding method is to earth-ground the shield wire of the communication cable. However, the earth-grounding of the communication cable is not easy at all, and it also causes an increased installation cost. There are three grounding points available for installation: 1.
  • Page 15: Power Connection

    Door Number Two Door Control Three Door Control Four Door Control • Refer to the list of compatible readers. - SSA-P400(T) : 26Bit Wiegand Reader - SSA-P401(T) : 34Bit Wiegand Reader DC +12V External Reader Internal Reader Reader #1 Reader #2...
  • Page 16 installation and external connection Input Connection Door Open Sensor Exit Button Door Open Sensor Exit Button - Exit Button Connection (Input #1, Input #3) Connect one line of the Exit button to an input port (Door 1: Input #1, Door 2: Input #3) of the Exit button. Connect the other line of the Exit button to GND (-).
  • Page 17 Output Connection DC +12V - If the door lock is in POWER FAIL SAFE mode: (Door 1: Relay #1, Door 2: Relay #3) Connect the COM line of the Door Lock relay to DC +12V. Connect the plus (+) line of the Door Lock to the Normal Close (NC) line of the Door Lock relay. Connect the minus (-) line of the Door Lock to GND (-).
  • Page 18: Communication Line Connection

    installation and external connection COMMUNICATION LINE CONNECTION RS-232 Communication Port Connection A 9-pin connector for serial communication is required to make connection to the PC. Connect the 9 pin connector for RS-232 communications as follows: HOST PC RS-232 9-Pin Female Connector Connect RS-232 TX to pin #2 of the 9-pin connector.
  • Page 19 RS-422 Communication Port Connection (Standalone) The RS-422/RS-232 converter is required to establish RS-422 communications. Connect the 9-pin connector of the RS-422/RS-232 converter as follows: RS-422/232 Converter RS-232C Power T+ T- R+ R- Connect RS-422 TX(-) to the RX(-) port of the converter. Connect RS-422 TX(+) to the RX(+) port of the converter.
  • Page 20 installation and external connection RS-422 Communication Port Connection (Multiple Units) The RS-422/RS-232 converter is required to establish RS-422 communications. RS-422/232 Converter Power T+ T- R+ R- - Follow the guidelines below to make connection between devices. Connect TX(-) of one device to TX(-) of other one. Connect TX(+) of one device to TX(+) of other one.
  • Page 21 TCP/IP Communication Port Connection 1) TCP/IP Communication Confi guration TCP / IP 2) TCP/IP Connection Connect the LAN cable to the TCP/IP RJ-45 jack as shown. (applicable only to SSA-P400T / SSA-P401T) Connect the RJ45 jack of the unit to the RJ45 plug, the LAN cable of the network system. Set a unique communication address (COMM ADDR) for each unit Install and launch the application (SAMS).
  • Page 22: System Initialization

    initialization SYSTEM INITIALIZATION Initializing the system using the Initialize switch Apply the power and initialize the system by using the initialization switch. Locate the Initialize switch ( switches simultaneously. • Pressing both of the switches at the same time for about 2 seconds will sound initialization ready beep.
  • Page 23: Board Id Setting

    BOARD ID SETTING Each device in the multi-serial communication connection is assigned a unique number to identify each other. The initial value of the switch is “0”, and all of the 8 switches are defaulted to OFF. Each switch has a unique value, and the board ID is the sum of the values of the switches. •...
  • Page 24: Troubleshooting

    TROUBLESHOOTING If the product does not work properly, please check the followings before contacting us. If the trouble persists, please contact the SAMSUNG Customer Service near you. Problem Can I specify RF only or RF+P/W mode differently according to the...
  • Page 25 - Check the communication settings of the PC application. Parity Bit : NONE, Data Bit: 8bit, Stop Bit: 1bit 2) Check the connection status of RS-232 and RS-422. RS-232 RS-422 (Independent Communication) SSA-P400 SSA-P400 TX Port RX(-) RX Port RX(+)
  • Page 26: Product Specifi Cations

    PRODUCT SPECIFICATIONS Item SSA-P400 Users 1,000 ~ 20,000 / 30,000 / 40,000 / 50,000 Users (Default :20,000) Event Buffer 20,000 ~ 29,500 / 3,000 / 8,000 / 14,000 (Default : 29,500) DC 12V, MAX. Power / Current...
  • Page 27 Correct Disposal of This Product (Waste Electrical & Electronic Equipment) (Applicable in the European Union and other European countries with separate collection systems) This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset, USB cable) should not be disposed of with other household waste at the end of their working life.

This manual is also suitable for:

Ssa-p401Ssa-p400tSsa-p401t

Table of Contents