General Information
The 5877GDPK includes the 5877 Relay Receiver and a SSA1 Z-Wave
provides an audible and visible warning that the garage door opener is being remotely activated.
If the system has been equipped for garage door control, installation of both the 5877 and SSA1 is required for
remote unattended garage door control. The installation of a 5822T Tilt Sensor or Door/Window Transmitter
(i.e.; 5816), allows the system to provide the status of up to three Garage Doors (one transmitter per door). The
System can be armed when the garage door is open, and once the garage door has been closed, the zone will be
monitored as part of the security system. It can also be programmed for monitoring only without providing
burglary protection. The panel also features the option to automatically close the Garage Door(s) if it has been
left open for more than a specified (programmable) period time or at a specified time.
Notes: 1. The system must be equipped with the L5100-ZWave Home Automation module.
2. The 5877GDPK is not compatible with:
- Chamberlin/Lift Master MyQ technology (Including but not limited to; Models 8550, 8360 and 8500).
- One piece or swinging garage doors.
3. Garage door control must have working entrapment protection (automatic reversing mechanisms and electronic photo eye
sensors that detect obstructions).
4. Both the 5877 Relay Receiver and the SSA1 Siren Strobe must be installed.
Enrolling the 5877 Relay Receiver and including the SSA1 Siren/Strobe module
Note: Ensure that the 5877 Relay Receiver is in close proximity to the LYNX
Touch while it is being enrolled. After the device has been enrolled it
can be mounted in its permanent position but should be tested to make
sure that it receives the Open/Close signals from the LYNX Touch.
1.
At the Dashboard screen select the "Automation" icon.
2.
At the second page of the Automation Screen, select the Garage door
setup icon.
3.
Select the Garage door to be enrolled, from the displayed list.
4.
Select "Assign device". The control advances to the Garage Door
operation screen.
5. Enter the 7-digit serial number associated with the 5877 Relay Receiver
then select "Done".
6. At the 5877 Relay Receiver, depress the Program button.
7. To confirm enrollment, at the LYNX Touch select the "Learn" button and
listen for a click at the relay.
8. At the Garage Door operation screen, select "Include Siren" to include the
SSA1 siren/strobe module.
9.
The panel displays "Entering Inclusion Mode. Please wait..." followed by
"Ready to Include device. Press the function button on device". Within one
minute press the siren's Function button.
10. If the module has been successfully enrolled, the panel displays "Device
Found! Please Wait" and then the device information is displayed.
Note: Repeat steps 2 through 10 to enroll up to two additional Garage Doors.
11. Select the " " button to return to the Automation screen.
Excluding the SSA1 Siren/Strobe module
1.
At the Dashboard screen select the "Automation" icon.
2.
At the second page of the Automation Screen, select the Garage door
setup icon.
3.
Select the desired Garage door, from the displayed list.
4.
At the Garage Door operation screen, select Exclude Siren **" to exclude
the SSA1 siren/strobe module.
5.
The panel displays "Entering Exclusion Mode. Please wait..." followed by
"Ready to Exclude device". Press the function button on device". Within
one minute press the siren's Function button.
6.
If the module has been successfully excluded, the panel displays the
device information.
Note: If the SSA1 is shared with additional garage doors it will be excluded
from each of those doors.
7. Select the " " button to return to the Automation screen.
Garage Door Feature Operation
1.
At the Dashboard screen select the "Automation" icon.
2.
At the Automation Screen, select the Garages icon.
3.
Select the Garage door that you wish to control/program from the
displayed list. The control advances to the Garage Door operation screen.
4. Refer to the procedures below for additional operation/programming
information.
ACTION
ACTION
ACTION
TM
Wireless Siren & Strobe Alarm. It
NOTES
• If System Status is desired, a House ID must
be enrolled in the LYNX Touch. Refer to the
System Type Programming Section of the
LYNX Touch Installation and Setup Guide P/N
800-10614V1 (or higher) or to the LYNX Touch
Programming Guide P/N 800-13468 (or higher)
OR 800-11060V1 (or higher) (Canada).
• The 5877 Relay Receiver should be enrolled in
the LYNX Touch before it is permanently
mounted.
• The SSA1 Wireless Siren and Strobe module
should be "included" in the LYNX Touch before
it is permanently mounted.
• The SSA1 Wireless Siren and Strobe module
must be "included" for each garage door that is
controlled
by
the
separately.
• A single SSA1 Wireless Siren and Strobe
module can be "included" for up to three garage
doors controlled by the LYNX Touch L5100 or
separate modules can be "included" for each
(up to 3) garage doors/5877 Relay Receivers.
• In order to display the garage door status, you
must also enroll a 5816 sensor or a 5822T Tilt
Sensor. Refer to the Zone Programming
Section of the LYNX Touch Installation and
Setup Guide P/N 800-10614V1 (or higher) or to
the LYNX Touch Programming Guide P/N 800-
13468 (or higher) OR 800-11060V1 (or higher)
(Canada).
The 5816 or 5822T is enrolled on Zones 46, 47
or 48, which are reserved for the Garage Door
operation. The 5816 is enrolled as loop 2 and
5822T as Loop 3.
NOTES
• If a single SSA1 Siren/Strobe Module that has
been included on multiple garage doors is
excluded, it will be excluded from ALL garage
doors that it had previously been included with.
NOTES
• The Garage Zone and Response Type must be
assigned in order to view garage door status.
5877
relay
receiver
loading

Summary of Contents for Honeywell L5100

  • Page 1 The panel also features the option to automatically close the Garage Door(s) if it has been left open for more than a specified (programmable) period time or at a specified time. Notes: 1. The system must be equipped with the L5100-ZWave Home Automation module. 2. The 5877GDPK is not compatible with: - Chamberlin/Lift Master MyQ technology (Including but not limited to;...