Communication; Variable Status - Siemens S7-1200 System Manual

Hide thumbs Also See for S7-1200:
Table of Contents
Web server
11.5 Standard Web pages
11.5.8

Communication

The communication page displays the parameters of the connected CPU, including the MAC
address, the IP address, and IP settings of the CPU.
Viewing the Communication page requires the "query diagnostics" privilege.
11.5.9

Variable Status

The Variable Status page allows you to view any of the I/O or memory data in your CPU.
You can enter a direct address (such as I0.0), a PLC tag name, or a tag from a specific data
block. For data block tags, you enclose the data block name in double quotation marks. For
each monitor value you can select a display format for the data. You can continue entering
and specifying values until you have as many as you want within the limitations for the page.
The monitor values show up automatically and refresh by default, unless you click the "Off"
icon in the upper right area of the page. When refresh is disabled, you can click "On" to re-
enable automatic refresh.
Viewing the Variable Status page requires the "read variable status" privilege.
If you login as a user with the "write variable status" privilege, you can also modify data
values. Enter any values that you wish to set in the appropriate "Modify Value" field. Click the
"Go" button beside a value to write that value to the CPU. You can also enter multiple values
and click "Modify All Values" to write all of the values to the CPU. The buttons and column
labels for modifying only appear if you have the "write variable status" privilege.