Table 8- 97
RET_VAL (W#16#....)
0000
8090
8091
8092
80A1
8.4.3.2

CAN_TINT (Cancel time of day interrupt)

Table 8- 98
CAN_TINT (Cancel date and time of day interrupt)
LAD / FBD
Table 8- 99
Data types for the parameters
Parameter and type
OB_NR
IN
RET_VAL
OUT
Table 8- 100 Condition codes
RET_VAL (W#16#....)
0000
8090
80A0
8.4.3.3

ACT_TINT (Activate time of day interrupt)

Table 8- 101 ACT_TINT (Activate date and time of day interrupt)
LAD / FBD
S7-1200 Programmable controller
System Manual, 03/2014, A5E02486680-AG
Condition code
Description
No error
Invalid OB_NR parameter
Invalid SDT start time parameter:
(for example, a start time within the skipped hour at the start of
daylight savings time)
Invalid PERIOD parameter
The start time is in the past.
(This error code only occurs with PERIOD = W #16#0000.)
SCL
ret_val:=CAN_TINT(_int_in);
Data type
Description
OB_TOD (INT)
OB number (accepts symbolic name)
Int
Execution condition code
Description
No error
Invalid OB_NR parameter
No start date / time set for that interrupt OB
SCL
ret_val:=ACT_TINT(_int_in_);
Extended instructions
8.4 Interrupts
Description
Cancels the start date and time
of day interrupt event for the
specified interrupt OB.
Description
Activates the start date and
time of day interrupt event for
the specified interrupt OB.