Page 1
For more information — Compressed air supply unit The Aztec ADS430 EZCLEAN compressed air supply Publications for the associated Aztec AWT440 unit is a rugged, reliable cubicle that delivers transmitter and Aztec ADS430 probe are available compressed air to an ABB compressed air adaptor for free download from: nozzle (part no.
4.2.1 24 V DC supply (compressor unit to Aztec AWT440 transmitter) ......10 4.2.2 Mains voltage supply (230 or 115 V AC) ..10 5 Configuration ............11 Sensor Setup ............. 12 2 OI/ADS430/EZCLN–EN Rev. B | Aztec ADS430 EZCLEAN | Compressed air supply unit...
This symbol indicates operator tips, particularly useful information or important information about the product or its further uses. The signal word 'IMPORTANT (NOTE)' does not indicate a dangerous or harmful situation. Aztec ADS430 EZCLEAN | Compressed air supply unit | OI/ADS430/EZCLN–EN Rev. B...
ABB has taken the decision to adopt the recommendations in the Directive as the target for all Recycle separately from general waste under the future product design and component purchasing. WEEE directive. OI/ADS430/EZCLN–EN Rev. B | Aztec ADS430 EZCLEAN | Compressed air supply unit...
Air intake (including dust filter) Fuse (2 A anti-surge) Instrument label Low voltage digital I/O connector Door locks Cable gland entry (low voltage digital I/O) Table 2.1 Aztec ADS430EZCLEAN – component descriptions Aztec ADS430 EZCLEAN | Compressed air supply unit | OI/ADS430/EZCLN–EN Rev. B...
3. Mount the compressor unit to the wall. Dimensions in mm (in.) (13.0) (15.0) (16.5) (10.3) (15.5) (7.7) (17.3) (8.1)* *Add 280 (11.0) when door open Fig. 3.1 Wall-mounting OI/ADS430/EZCLN–EN Rev. B | Aztec ADS430 EZCLEAN | Compressed air supply unit...
Arrangements above shown for example only. **485 (19.1) with door open Fig. 3.2 Handrail-mounting Aztec ADS430 EZCLEAN | Compressed air supply unit | OI/ADS430/EZCLN–EN Rev. B...
Fig. 4.1 Connecting 6 mm OD nylon tubing to the compressed air unit 2. Proceed to: — Section 4.1.2 to connect 6 mm OD nylon tubing to Fig. 4.3 Connecting 6 mm OD nylon tubing to the ABB flowcell – typical ABB compressed air adaptor (ADS430170) arrangement —...
24 V DC relay To positive (+) connection on compressed air unit 24 V DC relay Fig. 4.4 24 V DC connections – compressed air unit to Aztec AWT440 transmitter OI/ADS430/EZCLN–EN Rev. B | Aztec ADS430 EZCLEAN | Compressed air supply unit...
Sensor Setup level and return to Menu the Operator Page. Sensor Setup The configured clean commences at the interval set after this configuration is saved and repeats until re-configured or stopped. Exit Select Aztec ADS430 EZCLEAN | Compressed air supply unit | OI/ADS430/EZCLN–EN Rev. B...
(OI/ADS430-EN) for parameter descriptions. Salinity Units Pressure Units * Displayed only if Clean Interval is NOT set to Off ** Displayed only if Clean Type is set to Pulsed OI/ADS430/EZCLN–EN Rev. B | Aztec ADS430 EZCLEAN | Compressed air supply unit...
If the unit operates in a dusty environment, additional periodic cleaning may be required – use only a clean, dry cloth. Aztec ADS430 EZCLEAN | Compressed air supply unit | OI/ADS430/EZCLN–EN Rev. B...
**From digital I/O in transmitter or an external supply via the transmitter relay Acknowledgements RDO is a registered copyright of In-Situ Inc. INS HG PSIG Fig. 8.1 Pump unit – pneumatic pressure / flow rate Aztec ADS430 EZCLEAN | Compressed air supply unit | OI/ADS430/EZCLN–EN Rev. B...
Page 16
We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.