Samsung Healthy Living BM-501S Owner's Manual

Samsung Healthy Living BM-501S Owner's Manual

Manual inflate blood pressure monitor
Table of Contents
Available languages

Available languages

Owner's Manual
BM-501S
for model:
Manual Inflate
Blood Pressure Monitor
Made in Taiwan
105 Challenger Road, 6th Floor
Ridgefield Park, NJ 07660
• Manually Controlled Inflation
www. SAMSUNGHealthyLiving.com
• Large Three Row Digital Display
• Memory Stores 48 Measurements
• Time and Date Indications
• Pulse Display

Chapters

Table of Contents
loading

Summary of Contents for Samsung Healthy Living BM-501S

  • Page 1 Owner’s Manual BM-501S for model: Manual Inflate Blood Pressure Monitor Made in Taiwan 105 Challenger Road, 6th Floor Ridgefield Park, NJ 07660 • Manually Controlled Inflation www. SAMSUNGHealthyLiving.com • Large Three Row Digital Display • Memory Stores 48 Measurements • Time and Date Indications...
  • Page 2 Important Warnings/Medical Disclaimer Before using your blood pressure monitor, you should read and understand all instructions and follow all warn- ings. Information in this manual is provided for informational purposes only. This manual and product are not meant to be a substitute for the advice provided by your own physician or other medical professional.
  • Page 3: Table Of Contents

    Troubleshooting ________________________________22-23 Two Year Limited Warranty ________________________24-25 Specifications____________________________________26 Blood Pressure Diary_____________________________27-30 Copyright © 2005 Samsung America, Inc. All rights reserved. In This Manual Healthy Living This blood pressure monitor is the first step to living a healthier life. But monitoring your blood pressure at home is just the begin- ning, it’s also important to:...
  • Page 4: Healthy Living

    Healthy Living BE HAPPY! - A positive attitude is a big part of a healthy body. Try not to get too stressed out over things. Daily relaxation techniques such as gentle yoga or even quiet time by yourself can do a lot of good for the mind and body.
  • Page 5 Commonly Asked Questions About Blood Pressure When the heart contracts it sends blood out into the body. This pressure is referred to as systolic. The pressure that is created as the heart pulls blood back through is called diastolic. Blood pressure is recorded as systolic over diastolic, as shown here.
  • Page 6: Intended Use

    Commonly Asked Questions About Blood Pressure “the silent killer.” Don’t let it sneak up on you! Start monitoring your blood pressure every day with your new Healthy Living monitor. Why Is It Important To Control My Blood Pressure? Left uncontrolled, hypertension can place an incredible amount of stress on your heart and arteries, both of which become forced to work harder to keep blood flowing in a healthy manner throughout the body.
  • Page 7: Main Unit And Accessories

    Main Unit and Accessories Main Unit Cuff Inflation bulb Accessories 4 AA Alkaline Batteries Main Unit and Accessories Systolic Large Three Row Display display A large LCD with three rows displaying time, date, and your blood Diastolic pressure - systolic over diastolic - makes measuring your blood display pressure easy to read.
  • Page 8: Accuracy

    Accuracy Healthy Living monitors have been clinically tested against a scientific device called a sphygmomanometer, considered the gold standard in blood pressure measurement. All Healthy Living monitors have performed equivalent to measurements taken with this scientific device and are within the accuracy limits prescribed by the American National Standard for Electronic or Automated Sphygmomanometers.
  • Page 9: Selecting Time And Date

    Selecting Time and Date Healthy Living monitor will keep track of the time, month, and day unless the batteries have run down or are removed from the monitor. To set the month simply press the "MODE" button. The month will begin to flash. Press the "SET" button until the correct month appears on the display, then press the "MODE"...
  • Page 10: Applying The Cuff

    Important Reminders While Taking a Measurement ✓ Sit still and quietly while measuring. Talking or moving may elevate measurements. ✓ For consistency, it’s a good idea to measure your blood pres- sure using the same arm and at about the same time each day.
  • Page 11: Taking A Blood Pressure Measurement

    Taking a Blood Pressure Measurement Once the cuff is properly applied and you are seated with your • feet flat on the floor you are ready to take a measurement. Press "START/STOP" button. When the " • symbol flashes on the LCD screen, depress the knob to release the trapped air in the cuff before squeezing the inflation bulb to manually inflate the monitor until heart pulse appears on...
  • Page 12: Forty-Eight Measurement Memory

    Do not inflate the monitor’s cuff if it is not wrapped around your arm. ✓ Always remove the cuff tube from the monitor with care. ✓ For your safety, do not wrap the cuff around any other body part other than your arm. Taking Care of Your Blood Pressure Monitor...
  • Page 13: Troubleshooting

    Troubleshooting Error/Symbol What Does It Mean? Monitor may have been inflated without the cuff around the arm OR Cuff may not be posi- tioned correctly on the arm. You may have moved while the cuff was inflat- ing, it is now attempting to reinflate.
  • Page 14: Two Year Limited Warranty

    Two Year Limited Warranty Samsung America, Inc. will, at its option, repair or replace your monitor, includ- ing the cuff, with the same or comparable model free of charge (except you must pay for shipping charges set forth below) for a period of (2) two years from the date of original purchase in the event of a defect in materials or workman- ship occurring during normal use.
  • Page 15: Specifications

    Specifications Model BM-501S Monitor Type Manual Inflate Measurement Method Oscillometric Display Liquid crystal digital display Measurement Range Pressure: 0-260 mm Hg Pulse: 40-199 beats/Minute Accuracy Pressure: within ± 3mm Hg Pulse: within ± 5% Memory Stores up to 48 measurements...
  • Page 16 Blood Pressure Diary Date Time Systolic/Diastolic Blood Pressure Diary Pulse Blood Pressure Diary Date Time Systolic/Diastolic Pulse Blood Pressure Diary...
  • Page 17 Blood Pressure Diary Date Time Systolic/Diastolic Blood Pressure Diary Pulse Antes de ultilizar su medidor de presión arterial, debe leer y comprender todas las instrucciones y atender a todos los avisos. La información contenida en este manual y producto no sirve como sustituto a los consejos ofrecidos por su médico de cabecera o por otros profesionales médicos.
  • Page 18 Solución de Problemas___________________________22-23 Garantía Limitada de Dos Años _____________________24-25 Especificaciones _________________________________26 Diario de Presión Arterial_________________________27-30 Copyright © 2005 Samsung America, Inc. All rights reserved. En este Manual Healthy Living Este medidor de presión arterial es el primer paso a una vida Sana.
  • Page 19: Healthy Living

    Healthy Living Consulte siempre con su médico antes de realizar cambios en su dieta. Recuerde que, como siempre se ha dicho, ¡Uno es lo que come! SEA POSITIVO. Una mente sana está íntimamente ligada a un cuerpo sano. Las técnicas de relajación diaria como la meditación y el yoga pueden ser lo que necesite para aliviar el estrés diario.
  • Page 20: Preguntas Más Frecuentes Sobre La Presión Arterial

    Preguntas más Frecuentes Sobre la Presión Arterial Cuando el corazón se contrae, expulsa la sangre hacia el cuerpo. Esta presión se denomina sistólica. La presión creada cuando el corazón recibe la sangre se denomina distólica. La presión arterial se graba como sistólica y distólica tal y como se muestra en la figura ¿Qué...
  • Page 21: Proposito Del Uso

    Preguntas más Frecuentes Sobre la Presión Arterial silenciosamente a ústed! Comience a controlar la presión arte- rial a diario con su nuevo medidor Healthy Living . ¿Por qué es importante controlar la presión arterial? Si no se controla, la hipertención puede provocar una incredi- ble cantidad de estrés en su corazón y arterias, los cuales se ven forzados a trabajar más para que la sangre fluya de man- era normal por todo el cuerpo.
  • Page 22: Unidad Principal Y Accesorias

    Unidad Principal y Accesorios Unidad principal Banda ergometrica Balbula de inflación Accesorios 4 Baterias Alcalinas tipo AA Unidad Principal y Accesorios Medición Visualización Grande de tres filas sistólica Encontrará una visualidad mas grande en su monitor que le Medición permite ver el día, la hora y sus medidas de presión sistólicas distólica sobre las distólicas de manera muy facil.
  • Page 23: Precisión

    Precisión Los medidores Healthy Living han sido clínicamente probados con un dispositivo científico llamado esfigmometro, considerado como el estándar de oro para la medición de la presión arterial. Todos los medidores Healthy Living han dado resultados equiv- alentes a los tomados con este dispositivo científico y se encuentran dentro de los límites establecidos por El Estándar Nacional Americano para Esfigomómetros Electrónicos o Automatizados.
  • Page 24: Selección De La Fecha Y Hora

    Selección de la Fecha y la Hora Su medidor Healthy Living mantendra la hora, més y día a menos que se acaben las baterias o las quite. Para estable- cer la hora, pulse el botón "MODE". El més comenzará a parpadear.
  • Page 25: Colocación De La Banda Ergométrica

    Consejos Importantes Durante la medición ✓ Sientese callado y quietamente al tomarse la presión. El hablar o moverse puede elevar las medidas de su presión. ✓ Para mejores resultados, es recommendable tomarse la presión siempre en el mismo brazo y a la misma hora todos los días.
  • Page 26: Medición De La Presión Arterial

    Medición de la Presión Arterial • Presione el botón "START/STOP". El " balbula de presion aparecera en la pantalla LCD, presione la bálbula para sacar el aíre acomulado en la banda y vuelva a inflar la bálbula manual mente hasta que el pulso del corazon aparezca en la pantalla.
  • Page 27: Cuidados De Su Medidor De Presión Arterial

    Cuarenta y Ocho Mediciones en la Memoria Cuando se toma la presion arterial, automáticamente se guar- da en la posicion numero uno de la memoria de su monitor. A medida que se va tomando la presion, el monitor empujara la medida anterior un espacio hacia atras.
  • Page 28: Solución De Problemas

    Solución de Problemas Error/Símbolo ¿Qué significa? El medidor se pudo haber inflado sin estar abrochado en la muñeca o Puede que la banda no este bien colocada en la muñeca. Puede que se haya movi- do mientras la banda se estaba inflando y ahora intenta volver a inflarse.
  • Page 29: Garantía Limitada De Dos Años

    Garantía Limitada de Dos Años Samsung América Inc, a su propio criterio, reparará o sustituirá su medidor, incluyendo la banda, (por el mismo modelo u otro comparable) sin gasto alguno de su parte (excepto cargos de envío) durante el periodo de tiempo de (2) dos años desde la fecha original de compra.
  • Page 30: Especificaciones

    Especificaciones Modelo BM-501S Tipo de medidor Manual Inflación Metodo de medición Oscilométrico Pantalla Pantalla digital de cristal líquido Alcance de medición Presión: 0-260mmHg Pulso: 40-199 pulsaciones/minutos Precisión Presión: entre 3mm Hg Pulso: entre 5% Memoria Guarda hasta 48 mediciones Apago automático Cerca de 1 minuto tras completar la medición.
  • Page 31 Diario de Presión Arterial Fecha Hora Sistólica/Distólica Diario de Presión Arterial Pulso Diario de Presión Arterial Fecha Hora Sistólica/Distólica Pulso Diario de Presión Arterial...
  • Page 32 Diario de Presión Arterial Fecha Hora Sistólica/Distólica Pulso Diario de Presión Arterial...

Table of Contents