Siemens SINUMERIK 840DE User Manual

Configuring the ncu sinumerik 840d series
Hide thumbs Also See for SINUMERIK 840DE:
DATASHEET
SIEMENS
6FC5247-0AA00-0AA1
OTHER SYMBOLS:
6FC52470AA000AA1, 6FC52470AA00 0AA1, 6FC52470AA00-0AA1, 6FC5247 0AA000AA1, 6FC5247 0AA00 0AA1,
6FC5247 0AA00-0AA1, 6FC5247-0AA000AA1, 6FC5247-0AA00 0AA1, 6FC5247-0AA00-0AA1
RGB ELEKTRONIKA AGACIAK CIACIEK
SPÓŁKA JAWNA
Jana Dlugosza 2-6 Street
51-162 Wrocław
Poland
+48 71 325 15 05
www.rgbautomatyka.pl
www.rgbelektronika.pl
www.rgbelektronika.pl
www.rgbautomatyka.pl
Table of Contents
loading

Summary of Contents for Siemens SINUMERIK 840DE

  • Page 1 DATASHEET SIEMENS 6FC5247-0AA00-0AA1 OTHER SYMBOLS: 6FC52470AA000AA1, 6FC52470AA00 0AA1, 6FC52470AA00-0AA1, 6FC5247 0AA000AA1, 6FC5247 0AA00 0AA1, 6FC5247 0AA00-0AA1, 6FC5247-0AA000AA1, 6FC5247-0AA00 0AA1, 6FC5247-0AA00-0AA1 RGB ELEKTRONIKA AGACIAK CIACIEK SPÓŁKA JAWNA Jana Dlugosza 2-6 Street 51-162 Wrocław www.rgbelektronika.pl Poland [email protected] +48 71 325 15 05 www.rgbautomatyka.pl...
  • Page 2 YOUR PARTNER IN MAINTENANCE Repair this product with RGB ELEKTRONIKA ORDER A DIAGNOSIS LINEAR ENCODERS SYSTEMS INDUSTRIAL COMPUTERS ENCODERS CONTROLS SERVO AMPLIFIERS MOTORS MACHINES OUR SERVICES POWER SUPPLIERS OPERATOR SERVO PANELS DRIVERS At our premises in Wrocław, we have a fully equipped servicing facility. Here we perform all the repair works and test each later sold unit.
  • Page 3 Description of the NCU Configuring the NCU I/O Modules Manual Terminal Block DMP Compact Modules Maintenance and Service Abbreviations Valid for Index Control SINUMERIK 840D SINUMERIK 840DE (export version) SINUMERIK 840D powerline SINUMERIK 840DE powerline Drive SIMODRIVE 611 digital 03/2006 Edition...
  • Page 4 6FC5297-7AC10-0BP1 Trademarks All product names mentioned may be trademarks or product designations of Siemens AG or their suppliers, whose use by third parties for their own purposes may infringe the rights of the trademark owners. Other functions not described in this documentation might be executable in the control.
  • Page 5 Europe and Africa time zone A&D Technical Support Tel.: +49 (0) 180 / 5050 222 Fax: +49 (0) 180 / 5050-223 Internet: http://www.siemens.com/automation/support-request E-mail: mailto:[email protected] © Siemens AG, 2006. All rights reserved SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 6 In the Internet: http://www.ad.siemens.com/csinfo under the product/order no. 15257461 At the relevant branch office of the A&D MC group of Siemens AG. Safety information This manual contains information which you should observe in order to ensure your own personal safety, as well to avoid material damage. Notices which are relevant to your own personal safety are highlighted by a safety alert symbol;...
  • Page 7 Siemens. To ensure trouble-free and safe operation of the product, it must be transported, stored and installed as intended and maintained and operated with care.
  • Page 8 Danger Repairs to devices that have been supplied by our company must only be carried out by SIEMENS Customer Service or by repair centers authorized by SIEMENS. When replacing parts or components, only use those parts that are included in the spare parts list.
  • Page 9 (e.g. touch the unpainted metal parts of the control housing). Additional notes Important This notice indicates important facts that must be taken into consideration. Note This note contains additional important information. © Siemens AG, 2006. All rights reserved SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 10 03.06 Preface Notes © Siemens AG, 2006. All rights reserved viii SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 11: Table Of Contents

    ..7-86 DMP compact module 1A analog 6FC5111-0CA05-0AA0 ..7-88 © Siemens AG, 2006. All rights reserved SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 12 ............. . . Index-95 © Siemens AG, 2006. All rights reserved SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 13: System Overview

    The NCU is installed in a housing called the NCU box. This housing also con- tains a power supply and a fan subassembly. © Siemens AG, 2006. All rights reserved 1-11 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 14: 1.1 System Configuration

    Handheld unit Handheld terminal handheld unit Type B-MPI HT 6 *) MPI cable or MPI PG cable Fig. 1-2 SINUMERIK 840D system overview © Siemens AG, 2006. All rights reserved 1-12 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 15 In a multi-tier configuration, all the infeed supply units must be connected simultaneously. For cable, see Reference: Catalog NC 60, MOTION-CONNECT cables and connections © Siemens AG, 2006. All rights reserved 1-13 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 16 Components of the OP 012-PCU 50 configuration All the components, except for the printer, mouse and monitor are described in: Reference: /BH/, Operating Components Manual © Siemens AG, 2006. All rights reserved 1-14 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 17 31 out of 31 axes, max. 2 channels max. 2 channels max. 2 channels *) max. 10 channels *) for SW 7.2 or higher: max. 4 channels © Siemens AG, 2006. All rights reserved 1-15 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 18: Labels And Stickers

    Labels and stickers In case of technical queries or service, please quote all data on the rating plate to the local SIEMENS office responsible for your equipment. One of the following labels is attached to the components and modules: PCBs with screen Example: Component number: 570 573.9001.00...
  • Page 19: Non-Siemens Keyboards

    Otherwise, there may be problems with the PC keyboard. If you encounter problems, contact the relevant regional office. © Siemens AG, 2006. All rights reserved 1-17 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 20 03.06 1 System Overview 1.3 Non-Siemens keyboards Notes © Siemens AG, 2006. All rights reserved 1-18 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 21: Connection Conditions

    EC Machinery Directive 98/37/EC. Assistance and The connection conditions must be carefully maintained for the complete sys- support tem. Please contact your local Siemens office or representative for any assis- tance. © Siemens AG, 2006. All rights reserved 2-19...
  • Page 22 10 Events per hour 3 ms Transient voltage interruptions Idle time 10 s Recovery time 10 Events per hour © Siemens AG, 2006. All rights reserved 2-20 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 23: Safe Isolation To En 61800-5-1

    If necessary, these interfaces can be isolated safely using a supplementary adapter (insulation voltage 230 V AC). Although these adapters are not included in the Siemens scope of delivery, you can buy these parts from your local dealer, who will be happy to advise you.
  • Page 24 230 V AC each. 11. 5 V DC power supply with basic insulation, fed from a safely-isolated 24 V DC supply. © Siemens AG, 2006. All rights reserved 2-22 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 25: Grounding Concept

    The ground and module ground M should be connected at the power supply terminal of the IM 361. Further, for the EFP, “SHIELD” and “M24” must be con- nected in connector X1. © Siemens AG, 2006. All rights reserved 2-23 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 26: Ri Suppression Measures

    Exception: Standard shielded cables grounded on only one side can be used for devices from other manufacturers (printers, programming devices, etc.). © Siemens AG, 2006. All rights reserved 2-24 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 27 – Equipotential bonding conductor and PE conductor (routed together) Important For further notes on interference suppression measures and the connection of shielded cables, please refer to References: /EMC/ EMC Configuring Guidelines © Siemens AG, 2006. All rights reserved 2-25 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 28: Climatic And Mechanical Environmental Conditions

    Duration of nominal shock 6 ms Number of nominal shocks 18 shocks Shock form Half-sine g 9.81 m/s 2 (acceleration due to gravity) © Siemens AG, 2006. All rights reserved 2-26 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 29: Operating Conditions

    Derating At altitudes of 1000 to 4000 m above SL, the upper limit temperature is to be lowered by 3.5 °C/500 m. © Siemens AG, 2006. All rights reserved 2-27 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 30 Particular attention should be paid to cabling. Please contact your sales representative for assistance and support. If compliance with limit class B (residential areas) is required, please contact your local Siemens office or sales representative. © Siemens AG, 2006. All rights reserved 2-28...
  • Page 31: Mpi/Opi Network Rules

    When disconnecting an MPI node, first deactivate the connection and then remove the connector. 6. A maximum of two of the HHU and HT 6 components can be connected for each bus segment. © Siemens AG, 2006. All rights reserved 2-29 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 32 Max. total cable length is 200 m. Terminating resistor Fig. 2-3 MPI connector Reference: Catalog IK PI – Industrial Communication for Automation and Drives © Siemens AG, 2006. All rights reserved 2-30 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 33: Structure And Installation

    1. NCU box (sheet metal housing with a combined battery/fan slide-in module) for housing the NCU module. 2. NCU module (Numeric Control Unit) NCU box NCU module Fig. 3-1 Components of the SINUMERIK 840D © Siemens AG, 2006. All rights reserved 3-31 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 34: Installation Of The Sinumerik 840D

    Position of the NCU in the overall configuration Danger A hazardous voltage will be present for a further 5 minutes after the system has been shut down. © Siemens AG, 2006. All rights reserved 3-32 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 35 End-to-end DC link busbars Memory card Battery/fan slide-in module PE conductor connection Fig. 3-3 Installation of the NCU module in the NCU box © Siemens AG, 2006. All rights reserved 3-33 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 36 49.6 24.8 Space for exhaust air Space for supply air 24.8 Fig. 3-4 NCU cassette for Sinumerik 840D, dimensional drawing and installation instructions © Siemens AG, 2006. All rights reserved 3-34 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 37 For installation, it is recommended that the front plate at the link module be re- link module moved and then reattached after the installation. © Siemens AG, 2006. All rights reserved 3-35 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 38 03.06 3 Structure and Installation 3.2 Installation of the SINUMERIK 840D Notes © Siemens AG, 2006. All rights reserved 3-36 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 39: Description Of The Ncu

    *) With technological cycles and measuring cycles, max. 1.5 MB available for users. With ShopMill/ShopTurn 1.2 MB available to users in the basic configuration and no other CNC user memory options are possible. © Siemens AG, 2006. All rights reserved 4-37...
  • Page 40: 4.1 Components

    Features of the NCU modules: Standard PCMCIA card High-speed NC inputs and rapid NC outputs Measuring pulse inputs Handwheel inputs Voltage and temperature monitoring © Siemens AG, 2006. All rights reserved 4-38 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 41 References: /IAD/ Commissioning Manual 840D Caution Plugging the PCMCIA card in and out while energized will cause data to be lost! © Siemens AG, 2006. All rights reserved 4-39 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 42 NCU 573.3/4/5 in a group. Order No.: 6FC5212-0AA01-1AA0 96.5 +0.4 –1.4 16.8 37.4 Fig. 4-1 Link submodule Link cable Standard Profibus cable © Siemens AG, 2006. All rights reserved 4-40 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 43: Mounting

    Cable distributor Battery/fan slide-in module Power supply unit Sheet metal housing Fig. 4-2 Example: complete NCU box without a fan box with NCU 561.3 © Siemens AG, 2006. All rights reserved 4-41 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 44: Ncu Box With A Fan Box

    Example: complete NCU box with fan box and NCU 573.3 (Pentium III) Monitoring the An alarm is issued if a fan fails. fans © Siemens AG, 2006. All rights reserved 4-42 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 45 For replacing the fan box 1. Apply pressure to the locking spring on the front section of the fan box and 2. Slide the fan box downward. © Siemens AG, 2006. All rights reserved 4-43 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 46 Completely switch off the system. Check that it is safely isolated from the supply and safeguard against unauthorized switch-on. © Siemens AG, 2006. All rights reserved 4-44 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 47: Ncu Module Interfaces

    SIMODRIVE 611D interface X130A (611D module and NCU terminal block) Device bus connection X172 PCMCIA slot X173 Displays for faults, status, start-up Operating elements for start-up, general reset, reset © Siemens AG, 2006. All rights reserved 4-45 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 48 RESET button (S1) NCK start-up switch PLC start-up switch SIMODRIVE 611D interface Reserved Device bus interface PCMCIA slot (X173) Fig. 4-4 Front plate type 1 © Siemens AG, 2006. All rights reserved 4-46 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 49 RESET button (S1) NCK start-up switch PLC start-up switch SIMODRIVE 611D interface Device bus interface PCMCIA slot (X173) Fig. 4-5 Front plate type 2 © Siemens AG, 2006. All rights reserved 4-47 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 50 NMI button (S2) NCK start-up switch PLC start-up switch SIMODRIVE 611D interface Reserved Device bus interface PCMCIA slot (X173) Fig. 4-6 Front plate type 3 © Siemens AG, 2006. All rights reserved 4-48 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 51 M24ext *) P24ext *) RS_PROFIBUSDP XRS_PROFIBUSDP RTSAS_PROFIBUSDP RTSPG_PROFIBUSDP DGND *) 24 V only present if 24 V is fed to X121 (cable distributor). © Siemens AG, 2006. All rights reserved 4-49 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 52 Not assigned Not assigned Signal names Receive Data Transmit Data Request to Send Clear to Send Ground Signal type Output Input Voltage Output © Siemens AG, 2006. All rights reserved 4-50 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 53 Differential RS485 data – LINK Differential RS485 data – XRS_CLKCY; RS_CLKCY CLKCY DGND Signal Ground, isolated +5 V, isolated Signal type Bidirectional Output Voltage Output Input © Siemens AG, 2006. All rights reserved 4-51 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 54 Max. switching current per output: 500 mA (coincidence factor 100%). For an inductive load, an external protective circuit is required for unloading the inductivity © Siemens AG, 2006. All rights reserved 4-52 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 55 X130A SIMODRIVE 611D interface Connector name: X130A Connector type: 2x36-pole Micro Ribbon Maximum cable length: 10 m Special features: Non-isolated (no safe isolation) © Siemens AG, 2006. All rights reserved 4-53 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 56 Drive and NC operationally ready Signal type Open Collector Voltage Input X173 PCMCIA slot Connector name: X173 Connector type: 68-pole PCMCIA card connector, male © Siemens AG, 2006. All rights reserved 4-54 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 57 (e.g. bus short-circuit, no token circulation) 7-segment Software-assisted output of test and diagnostics messages On the SIMATIC CPU 315-2DP, the LED is called “BUSF”. © Siemens AG, 2006. All rights reserved 4-55 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 58: Cable Distributor (Distributor Box)

    Figure showing the position of the interfaces of the cable distributor (see below). © Siemens AG, 2006. All rights reserved 4-56 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 59 Sub-D female connector S1 to S6: Closed Open 1) Not for Order No. 6FX 2006-1BA00 Fig. 4-8 Position of the interfaces of the cable distributor © Siemens AG, 2006. All rights reserved 4-57 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 60 Note When assembling the cable distributor, make absolutely sure that the supplied insulating washer is installed correctly and the coding pins are installed. © Siemens AG, 2006. All rights reserved 4-58 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 61 MPG 0/1 0V supply voltage handwheel 0/1.0 V MPG 0/1 A/XA differential handwheel input 0/1, A/XA MPG 0/1 B/XB differential handwheel input 0/1, B/XB © Siemens AG, 2006. All rights reserved 4-59 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 62: Technical Data

    Degree of contamination Cooling Open circuit ventilation Mechanical ambient conditions Transport 2M2 according to EN 60721–3–2 (in transport packaging) Bearings 1M2 according to EN 60721–3–1 © Siemens AG, 2006. All rights reserved 4-60 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 63 *) NCU with NCU box, without handwheel and I/O Note The NCU is supplied with power via the device bus (HF1/2) from the SIMODRIVE infeed module (see Table 4-10). © Siemens AG, 2006. All rights reserved 4-61 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 64 03.06 4 Description of the NCU 4.5 Technical data Notes © Siemens AG, 2006. All rights reserved 4-62 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 65: I/O Modules

    Ribbon cable Terminal strip converter Ï Ï Ï Ï X402 32 O Fig. 5-1 Overview of connections, single I/O modules on the SINUMERIK 840D © Siemens AG, 2006. All rights reserved 5-63 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 66 . The connection must be as short as possible. When the PE and interference conductors are in common, the PE conductor rules in EN 61800–5–1 must be followed. © Siemens AG, 2006. All rights reserved 5-64 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 67: 5.1 Single I/O Module

    Coincidence factor Total of all nominal currents within each group of 0.5 A Degree of protection IP20 or IPXXB Weight 1.7 kg © Siemens AG, 2006. All rights reserved 5-65 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 68 P24 Power Signal names P24 Power +24 V electronics load power supply external Electronics load power supply ground external Signal type Voltage Input © Siemens AG, 2006. All rights reserved 5-66 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 69 OUT2 0 OUT2 1 OUT2 2 OUT2 3 OUT2 4 OUT2 5 OUT2 6 OUT2 7 OUT3 0 OUT3 1 OUT3 2 OUT3 3 © Siemens AG, 2006. All rights reserved 5-67 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 70 INP3 2 INP3 3 INP3 4 INP3 5 INP3 6 INP3 7 Signal names INPi[j] Input j of input byte i Signal type Input © Siemens AG, 2006. All rights reserved 5-68 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 71 From the PLC’s viewpoint, the 840D single I/O is equivalent to a S7-300 I/O chain with the following configuration: P-bus interface IM-R 2 x 32-bit input module 1 x 32-bit output module © Siemens AG, 2006. All rights reserved 5-69 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 72 Chain 1 X111 I/O bus Chain 2 Chain 3 SINUMERIK 840D with integrated Fig. 5-3 SINUMERIK 840D with 3 I/O chains (max. configuration) © Siemens AG, 2006. All rights reserved 5-70 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 73: Terminal Block

    In order to ensure optimum heat dissipation of the DMP compact module, the terminal block should be secured horizontally, so that the modules can be sus- pended vertically. © Siemens AG, 2006. All rights reserved 6-71 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 74 When the PE and interference conductors are in common, the PE conductor conductor rules in EN 61800–5–1 must be followed. PE conductor connection, see Fig. 6-1. © Siemens AG, 2006. All rights reserved 6-72 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 75 DMP outputs have to be reset via the PLC program when the load supply voltage is switched off. The outputs are set again after the voltage has been switched on again. © Siemens AG, 2006. All rights reserved 6-73 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 76 Pins 1 and 2 or 3 and 4 are bridged in a group on the module. Signal names P24 ext +24 V power supply external M24 ext Power supply ground external Signal type Voltage Input © Siemens AG, 2006. All rights reserved 6-74 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 77 40 mm Weight Approx. 0.5 kg Ambient conditions Degree of protection IP20 or IPXXB Power consumption (24 V) During operation 150 – 500 mA © Siemens AG, 2006. All rights reserved 6-75 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 78 03.06 6 Terminal Block 6.1 NCU terminal block 6FC5211-0AA00-0AA0 Notes © Siemens AG, 2006. All rights reserved 6-76 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 79: Dmp Compact Modules

    0 1 2 3 4 5 6 7 G P Inputs IN 0 ... IN 7 LOW byte Fig. 7-1 Front view and side view of a DMP compact module 16E © Siemens AG, 2006. All rights reserved 7-77 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 80 = type 1 ms Delay time for tp = type 1 ms Length for cables Maximum 30 m Weight About 125 g © Siemens AG, 2006. All rights reserved 7-78 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 81: Dmp Compact Module 16 A 6Fc5111-0Ca02-0Aa1

    20.4 V to 28.8 V – Ripple 3.6 Vpp Signal level of the outputs (typically) – For signal “0” Open – For signal “1” –250 mV load © Siemens AG, 2006. All rights reserved 7-79 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 82 All 16 outputs can be loaded simultaneously with 0.25 A for example. Important If inductive loads are used, switching voltage peaks must be limited by external free-wheeling diodes or RC connections. © Siemens AG, 2006. All rights reserved 7-80 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 83: Dmp Compact Module 8 A 6Fc5111-0Ca03-0Aa1

    8 LEDs as a status display for the logical states of the outputs. As of product version B, the LEDs go out when the load voltage fails. LEDs lit: Output on © Siemens AG, 2006. All rights reserved 7-81 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 84 All 8 outputs can be loaded simultaneously with 1 A for exam- ple. Important If inductive loads are used, switching voltage peaks must be limited by external free-wheeling diodes or RC connections. © Siemens AG, 2006. All rights reserved 7-82 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 85: Dmp Compact Module 1I Analog 6Fc5 111-0Ca04-0Aa0

    Setting of the measurement range 1–2 closed: +10 V 1–3 closed: +500 mV Setting the line frequency closed: for 50 Hz systems open: for 60 Hz systems © Siemens AG, 2006. All rights reserved 7-83 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 86 (" 20 V; "1 V) "0.2% Basic error limits "0.5% Operational limits (0 C to 60 Length of cables (shielded) max. 30 m Weight about 150 g © Siemens AG, 2006. All rights reserved 7-84 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 87 OR= Overflow bit, input voltage is greater than 20 V or 1 V (double input range) PF = Power supply failure of the analog part © Siemens AG, 2006. All rights reserved 7-85 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 88: Dmp Compact Module 1E Nc Analog 6Fc5211-0Aa10-0Aa0

    4.88 mV for one bit. The duration for a converter cycle (from triggering of conversion to the time at which the result can be read out) is max. 75 µs. © Siemens AG, 2006. All rights reserved 7-86...
  • Page 89 Total error over temperature range 0 to 55 C including zero error Length of cables (shielded) Max. 30 m Weight Approx. 160 g © Siemens AG, 2006. All rights reserved 7-87 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 90: Dmp Compact Module 1A Analog 6Fc5111-0Ca05-0Aa0

    As of product version B: 330 µs Display elements 1 LED as a status display for the power supply. LED lit: internal power supply OK © Siemens AG, 2006. All rights reserved 7-88 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 91 Signifi- cance cance SG 2 SG 2 always always +9.9988 V +1.22 mV Digital value –1.22 mV –10 V © Siemens AG, 2006. All rights reserved 7-89 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 92 7 DMP Compact Modules 03.06 7.6 DMP compact module 1A analog Notes © Siemens AG, 2006. All rights reserved 7-90 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 93: Maintenance And Service

    The batteries must not be recharged because this could cause leakage and/or explosion. Non-compliance can cause injury to people or damage to property. © Siemens AG, 2006. All rights reserved 8-91 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 94 3. Install the new slide-in module. (within 15 minutes) 4. Switch the controller on again, the battery alarm should now be off. © Siemens AG, 2006. All rights reserved 8-92 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 95 Industry Standard Architecture Light Emitting Diode Handheld Terminal Machine Control Panel MLFB (Order no.) Machine-Readable Product Designation (order no.) Multi Point Interface: Multi-point serial interface © Siemens AG, 2006. All rights reserved A-93 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 96 Random Access Memory: Program memory that can be read and written to SRAM Static RAM: Static memory (battery-backed) End User Interface Video Graphics Adapter © Siemens AG, 2006. All rights reserved A-94 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 97: Index

    DMP compact modules, 6-73, 7-77 NCU switch positions, meaning, 4-55 Driver module, 4-39 NCU terminal block, 6-71 Dust, that can adversely affect function, 2-28 © Siemens AG, 2006. All rights reserved Index-95 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 98 Secondary electrical conditions, 2-19 X122, 4-53 Shielded signal cables, 2-24 X130A, 4-53 SIMATIC interface, X111, 4-50 X172, 4-54 SIMODRIVE 611D interface, X130A, 4-53 X173, 4-54 © Siemens AG, 2006. All rights reserved Index-96 SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition...
  • Page 99 Suggestions SIEMENS AG Corrections A&D MC MS For Publication/Manual: Postfach 3180 91050 ERLANGEN, GERMANY SINUMERIK 840D Configuring the NCU Tel.: +49 (0) 180 5050 – 222 [Hotline] Fax: +49 (0) 9131 98 – 63315 [Documentation] Manufacturer/Service Documentation mailto:[email protected] Manual From Order No.: 6FC5297-7AC10-0BP1...
  • Page 100 Documentation Overview SINUMERIK 840D/840Di/810D (03/2006) General Documentation Safety SINUMERIK SINUMERIK Integrated 840D 840Di 810D Brochure Catalog NC 60 *) Safety Integrated Application Manual User Documentation SINUMERIK SINUMERIK SINUMERIK SINUMERIK SINUMERIK SINUMERIK 840D 840D sl 840D sl 840Di 840D sl 840D sl 840Di 840D 840D...

This manual is also suitable for:

Sinumerik 840dSinumerik 840d powerlineSimodrive 611 digital

Table of Contents