Siemens SIMATIC ITP1000 Operating Instructions Manual

Siemens SIMATIC ITP1000 Operating Instructions Manual

Industrial tablet pc
Hide thumbs Also See for SIMATIC ITP1000:
Table of Contents
SIMATIC
Industrial Tablet PC
SIMATIC ITP1000
Operating Instructions
05/2017
A5E37340160-AB
___________________
Preface
___________________
Overview
___________________
Safety notes
___________________
Commissioning the device
___________________
Devise functions and
operating the device
___________________
Device maintenance and
repair
___________________
Technical specifications
___________________
Technical Support
___________________
Labels and symbols
___________________
Abbreviations
1
2
3
4
5
6
A
B
C
Table of Contents
loading

Summary of Contents for Siemens SIMATIC ITP1000

  • Page 1 ___________________ Preface ___________________ Overview ___________________ SIMATIC Safety notes ___________________ Commissioning the device Industrial Tablet PC SIMATIC ITP1000 ___________________ Devise functions and operating the device ___________________ Device maintenance and repair Operating Instructions ___________________ Technical specifications ___________________ Technical Support ___________________ Labels and symbols...
  • Page 2: Legal Information

    Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    For supplementary instructions on how to handle the software, please refer to the corresponding manuals. Conventions The term "device" is sometimes used to refer to the SIMATIC ITP1000 product in this documentation. History Currently released versions of this operating manual:...
  • Page 4 Preface SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 5: Table Of Contents

    General information on commissioning .................. 31 Power supply .......................... 32 3.3.1 Notes on battery operation ..................... 32 3.3.2 Connecting the power supply ....................35 Switching on the unit ....................... 38 Operating modes ........................39 Connecting peripheral devices ....................40 SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 6 Setting up the language selection using the Multilanguage User Interface (MUI) ....65 5.4.7.1 Setting up the language selection in Windows 7 ..............65 5.4.7.2 Setting up the language selection in Windows 10 ..............67 Backing up data ........................68 Recycling and disposal ......................68 SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 7 General problems ......................... 102 A.2.2 Problems with WLAN ......................103 Labels and symbols ..........................105 Overview ..........................105 Safety ............................ 105 Operator controls ........................105 Certificates, approvals and markings ..................106 Interfaces ..........................107 SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 8 Table of contents Abbreviations ............................109 Abbreviations ........................109 Index ..............................111 SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 9: Overview

    Overview Product description 1.1.1 Overview SIMATIC ITP1000 is a high-performance Tablet PC and specially customized to the requirements of industrial applications. ● High-level performance and high graphics performance ● High functionality ● Extremely robust ● Compact design SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 10: Application Areas

    ● Externally accessible ports such as LAN, serial port, USB type A and type C, MiniDisplay port ● Touch screen with multitouch function ● Continuous running duty up to +45 °C ● Height of fall tested according to MIL810 SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 11: Features

    User program • Card reader • WLAN/Bluetooth • Camera Full HD, for documentation purposes Storage media SSD, ≥ 256 GB • M.2, SATA • For information on capacity, refer to the ordering documents • SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 12 Anti-theft protection Kensington lock Software Operating system: Installed: Windows 7 Ultimate 64-bit, 6 languages • German, English, French, Spanish, Italian, Chinese Windows 10 2016 LTSB, 6 languages • German, English, French, Spanish, Italian, Chinese SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 13: Design Of The Device

    You will find information on the functions of the individual components in the following sections: ● On/off button (Page 17) ● Buttons (Page 17) ● Status displays (Page 18) ● Use RFID reader (Page 47) SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 14: Back

    Top view ① Card reader for: SD card (including SD UHS-II) • Multi Media Card (MMC) • ② Ethernet ③ 2 x USB 3.0 Type A ④ Mini DisplayPort ⑤ RS-232 ⑥ Ventilation slots SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 15: Bottom View

    Barcode reader ② Interface for docking station 1.2.1.5 Left view ① Universal audio jack (UAJ) Connection for audio devices ② USB 3.0 Type C ③ Socket for connection to the power supply: DC-In 19 V SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 16: Right View

    Overview 1.2 Design of the device 1.2.1.6 Right view ① Opening for Kensington lock SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 17: Operator Controls

    ● freely configurable with the SIMATIC IPC Configuration Center ● SIMATIC IPC Configuration Center is pre-installed in delivery condition. ● For more information, refer to SIMATIC IPC Configuration Center in section "Configuring the device (Page 45)". SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 18: Status Displays

    The wireless LED relates both to WLAN and to Bluetooth. You may customize both functions in the corresponding application during installation of the software. Symbol Meaning Colors Meaning of colors WLAN/Bluetooth ORANGE Radio connection switched on Radio connection switched off SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 19: Layout Of The Docking Station

    Device in docking station Front view ① 2 x latching, magnetic ② 2 x Docking Detect buttons ③ 4 x supporting foot ④ 2 x sliding surface for centering the device ⑤ Cover for docking connector SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 20 1.3 Layout of the docking station Top view ① Docking connector Connections to the docking station ① Ethernet ② 2 x USB 2.0 Type A ③ Display Port ④ Socket for connection to the power supply: DC-In 19 V SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 21: Accessories

    4. Navigate to your device in the product catalog (tree structure on the left): "Automation Engineering > PC-based automation > Industry PC > Tablet PC > ..." 5. In the tree structure on the left, click: SIMATIC ITP1000. 6. Select the "Accessories" tab in the display area.
  • Page 22 Overview 1.4 Accessories SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 23: Safety Notes

    Do not look directly in the light beam of the camera LED when using the camera. Keep a distance of at least 20 cm between your eyes and the camera LED. Figure 2-1 Warning notice on the rear of the device. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 24 Contact your technical support team or where you purchased your PC to find out which system expansion devices may safely be installed. NOTICE Warranty If you install or exchange system expansions and damage your device, the warranty becomes void. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 25 ● Always pull the mains connector and disconnect the battery before you install or remove modules which are sensitive to ESD. ● Handle modules fitted with ESDs by their edges only. ● Do not touch any wiring posts or conductors on modules containing ESDs. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 26: Safety Note On Barcode Reader And Rfid Reader

    In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks.
  • Page 27: Safety Guidelines For Transport

    If you are transporting the device in extreme weather conditions with large fluctuations in temperature, care must be taken to ensure that no moisture forms on or in the device (condensation). If condensation develops, wait at least 12 hours before switching on the device. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 28: Notes About Usage

    Note Requirements for base on which device is operated Avoid any damage to the device from scratching or overheating. Only place the device on a flat, even, clean and hard base. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 29: Commissioning The Device

    ● Check the delivery and your specially ordered accessories against the packaging list to ensure nothing is missing. ● If you determine any transport damage or defects when unpacking the device, notify your local sales outlet. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 30: Noting The Device Identification Data

    Only for devices that are delivered with operating system. The COA label is only found on devices that are delivered with installed operating system. It is located on the underside of the device. Example: SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 31: General Information On Commissioning

    Make sufficient allowances for the device to warm up to room temperature before you put it into use. If condensation develops, wait at least 12 hours before switching on the device. Requirements for commissioning ● The power supply is connected or the battery is fully charged. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 32: Power Supply

    NOTICE Risk of fire - Hazardous to people and the environment The improper disposal of batteries may cause fire. Observe the local regulations for the disposal of recyclable materials. Dispose of batteries properly. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 33 LED battery in the battery operation lights up red as a warning. End your work and save your data. There are now only a few minutes battery running time left. Please note that for a complete disconnection from the mains the mains connector must be removed. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 34 A loss of capacity over time is technology-dependent and, as with all manufacturers of comparable devices, it is excluded from the warranty. In the case of a significant drop of efficiency we recommend that you replace the battery. Use only Siemens original spare parts.
  • Page 35: Connecting The Power Supply

    No mobile operation of the device when the power supply is connected When connected to the power supply, only operate the device on a table or in the docking station, refer to section "Left view (Page 15)". SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 36 Danger of damage to the device or destruction of the battery Only use the supplied battery or an original spare part. You can find more information on the original replacement parts of the device in section: "Accessories (Page 21)". SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 37 At least 18 AWG (0.82 mm conductor cross-section and 15 A/250 V connector. The cable set must conform to the safety regulations of the country in which the devices are installed, and bear the prescribed markings in each case. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 38: Switching On The Unit

    The product key can be found on the COA label, see section "Noting the device identification data (Page 30)". Result From now on, after you switch on the PC, the user interface of the operating system is automatically opened when the startup routine is completed. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 39: Operating Modes

    You will recognize these operating states, as all status-LEDs of the device are switched off when power supply is removed. This way you can ensure the device is not switched on and the battery is not unintentionally discharged during transportation. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 40: Connecting Peripheral Devices

    (connecting the cable shielding to the protective conductor). WARNING Inter-building networks Only the LAN interface on the docking station is permitted for inter-building networks. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 41 – OMTP: Standard for audio devices from Nokia, etc. – CTIA: Standard for audio devices from Apple® Note Connection of microphone and headphones with two 3.5mm jacks An adapter is needed to simultaneously connect a microphone and headphones to a 3.5-mm-jack. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 42 Commissioning the device 3.6 Connecting peripheral devices SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 43: Devise Functions And Operating The Device

    "Battery" LED. Remove device from docking station ● Tilt the device slightly forward to release it from the magnetic latching. ● Then remove the device by pulling it upwards. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 44: Charging The Device

    Charging the device with external power supply unit ● Connect the external power supply unit to the device. ● Operate the device during the charging operation only on a table and not in mobile mode. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 45: Configuring The Device

    Using barcode reader You can find information on the position of the barcode reader in the section "Front (Page 13)". The barcode reader is freely configurable. Technical support is available from SIEMENS Customized Automation (hhttp://w3.siemens.com/mcms/human-machine-interface/en/customized- products/Pages/Default.aspx). Scanning barcode 1. Press and hold down the function key to activate the barcode reader. Refer to the Configuration of the function keys (Page 17).
  • Page 46 Devise functions and operating the device 4.1 Notes on operation Resetting the barcode reader to delivery state Deactivate parameter scan Activate parameter scan Activate 2 out of 5 interleaved SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 47: Use Rfid Reader

    Use RFID reader Information about the position of the RFID reader can be found in the section "Front (Page 13)". The RFID reader is freely configurable. Technical support is available from SIEMENS Customized Automation (hhttp://w3.siemens.com/mcms/human-machine-interface/en/customized- products/Pages/Default.aspx). Recording RFID tag 1. Press the key to activate the RFID reader Refer to the Configuration of the function keys (Page 17).
  • Page 48: Using Camera

    The integrated Ethernet interfaces (10/100/1000 Mbps) can be used for communication and data exchange with programmable controllers. WLAN You can link the device to an Industrial Wireless LAN network using the integrated WLAN interface. Information on Industrial Wireless LAN can be found in SIEMENS Industrial Wireless Communication (http://www.automation.siemens.com/mcms/automation/en/industrial- communications/iwlan-industrial-wireless-communication) Further information...
  • Page 49: Intel Active Management Technology

    Press when the BIOS appears briefly during startup and select the BIOS start page MEBx. Note Password protection for the AMT PC AMT enables virtually unrestricted access to the AMT PC. Protect access to the AMT PC by means of password. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 50: Trusted Platform Module (Tpm)

    Note Improper usage poses the risk of data loss. Always keep the keys and passwords in a secure place. Encrypted data cannot be retrieved. The Siemens warranty does not cover a hardware reset after loss of the password. SIMATIC ITP1000...
  • Page 51: Wlan And Bluetooth

    WLAN. These can be a local network (e.g. company networks) or a global network (e.g. Internet). More detailed information on configuring and operating the WLAN can be found in the online help of the WLAN network adapter. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 52: Safety Notices For Wlan And Bluetooth Operation

    Siemens. The user alone is responsible for remedying faults that have been caused by such an unauthorized change, or for the use or the replacement of the device.
  • Page 53: Device Maintenance And Repair

    2. Spray the cleaning solution onto a cleaning cloth. Do not spray directly onto the device. 3. Clean the device. When cleaning the display wipe from the screen edge inwards. 4. Unlock the touch screen by pressing the Locking key again. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 54: Replacement Interval

    An original replacement part, refer to section "Accessories (Page 21)". Procedure 1. Turn the device over so that it is lying on a flat surface. ① 2. Remove the two screws on the underside of the device and store these safely. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 55 6. Insert the new battery with the battery cover, as shown, at an angle from above ④ then lower it ① 7. Close the battery cover and fasten it with the two remaining screws SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 56: Ssd Kit

    With the SATA to USB 3.0 adapter (order no. 6ES7790-1AA01-0AA0), you can easily create an image of your system for backup purposes, or as the basis for system-specific installations. See also Accessories (Page 21) SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 57: Change Ssd

    5.3 Installing and removing hardware 5.3.3 Change SSD Note The SSD module should only be exchanged by the SIEMENS Repair Service. You can find information on this on the Internet at: SIEMENS Repair Service (https://support.industry.siemens.com/cs/ww/en/sc/2154). 5.3.4 Replacing the backup battery The device has a backup battery.
  • Page 58: Reinstalling The Software

    6. Open the folder with the driver data by clicking on the link next to "Driver path". 7. Start the setup program in this folder. Note For a new installation of Windows operating systems, the chipset driver must be installed before all other drivers, if required. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 59: Reinstalling The Operating System

    If you have ordered a device with operating system, the Restore function is included on the USB stick. Documentation and drivers The supplied USB stick contains the directory "DocuAndDrivers". You can find the documentation, hardware drivers and updates here: In Windows, these contains are available via a menu. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 60: Restoring The Delivery State

    The BIOS selection menu appears when the initialization has been completed. 4. To boot from the USB stick, select the "Boot Manager" in the BIOS selection menu, refer to section "Opening the BIOS selection menu (Page 84)". SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 61: Updating The Operating System

    English (US), see section "Setting up the language selection using the Multilanguage User Interface (MUI) (Page 65)". other operating systems Contact the corresponding manufacturer. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 62: Installing Windows 7

    During the installation of Windows, all data, user settings and all authorizations or license keys on drive C: are deleted. • Back up all data. • Check the data and time in the BIOS Setup menu "Main" and correct the displayed date and time if required. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 63 1. Connect the USB stick with the controller driver to the device. 2. Start the "Install Windows" installation program as described above. 3. Select "Load Drivers" in the Windows installation window. 4. Select the respective driver on the USB stick. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 64: Setting Up Partitions In Windows

    Information on how the data medium is partitioned in its factory state is available in the tables below. 2. Select the partition on which you want to install the operating system. 3. Click "Next". Installation is started. The Windows operating system is installed on the data medium. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 65: Setting Up The Language Selection Using The Multilanguage User Interface (Mui)

    1. Choose: "Start > Control Panel > Clock, Language, and Region > Region and Language" 2. You can make the required changes in the "Administrative" tab. You copy the settings by clicking the respective button. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 66 "Languagepacks" folder. 1. Choose: "Start > Control Panel > Clock, Language, and Region > Region and Language" 2. Select the "Keyboards and Languages" tab. 3. Click the "Install/uninstall languages" button and make the required changes. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 67: Setting Up The Language Selection In Windows 10

    2. Enter the following command in the command line: Dism /online /Add-Package /PackagePath:#Path to the language pack# For " ", enter the path to the language pack you want to install. #Path to language pack# Example: Dism /online /Add-Package /PackagePath:E:\Languagepacks\ja-jp\lp.cab SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 68: Backing Up Data

    (images). The SIMATIC IPC Image & Partition Creator can be ordered using the Siemens online ordering system (https://mall.industry.siemens.com). For more information about SIMATIC IPC Image & Partition Creator, refer to its product documentation.
  • Page 69: Technical Specifications

    Technical specifications Certificates and approvals ISO 9001 certificate The Siemens quality assurance system for all product creation processes (development, production and sales) meets ISO 9001 requirements. This has been certified by DQS (the German society for the certification of quality management systems).
  • Page 70: Directives And Declarations

    Connecting peripherals Noise immunity requirements to EN 61000-6-2 are met if connected peripherals are suitable for industrial applications. Peripheral devices must only be connected using shielded cables. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 71: Esd Guidelines

    The electrostatic discharge current may lead to latent failure of a module, that is, this damage may not be significant immediately, but in operation may cause malfunction. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 72 In this way, the discharged energy can not affect the sensitive devices. Discharge your body before you start taking any measurements on a module. Do so by touching grounded metallic parts. Always use grounded measuring instruments. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 73: Technical Specifications

    IP 40 (with closed covers) according to IEC 60529 Safety Protection class Safety class II according to IEC 61140 Safety specifications IEC 60950-1/EN 60950-1 • UL 60950-1 Second Edition • CAN/CSA-C22.2 No. 60950-1-07 Second Edition • SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 74 –20 °C to + 60 °C at max. 20 °C/h (no condensation) Relative humidity tested to IEC 60068-2-78, IEC 60068-2-30, IEC 60068-2-14 During operation 5% to 85% at 30°C/h (no condensation) Storage/transport 5% to 95% at 25°C/h (no condensation) SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 75 • documents Graphic Graphic controller Intel® HD graphics 530 Graphic controller memory part of the graphic memory is dynamically shared in the system memory Resolutions/frequencies/colors according to the setting options of the graphics driver SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 76: Lcd Display

    1 x USB 3.0 Type C (left): Max. 1.5 A • 2 x USB 3.0 Type A (top): Max. 0.9 A • Ethernet 1 x Gigabit Ethernet (RJ45) DC-In DC power supply input, jack plug Headphones, microphone, headset UAJ connection for 3.5mm jack SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 77 Card reader Interface for: SD card (including SD UHS-II) • Multi Media Cards • Status displays on the device ● Rechargeable battery ● Operation ● Mass storage ● User program ● Card reader ● WLAN/Bluetooth SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 78: External Interfaces

    Meaning Input/output VBUS + 5 V (fused) USB 3.0 Type A Output Data line Input/output Data line Input/output Ground – Data line Input Data line Input Ground – Data line Output Data line Output SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 79: Usb 3.0 Type C

    Configuration channel Input/output Data cable (USB 2.0) Input/output Data cable (USB 2.0) Input/output Not used VBUS + 5 V (fused) Output RX1- Data cable (USB 3.0) Input RX1+ Data cable (USB 3.0) Input Ground SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 80: Rs232 (Com1)

    Meaning Input / output Data carrier detect Input Received data Input Transmit data Output Data terminal ready Output Ground Ready for operation Input Request to send Output Clear to send Input Incoming call Input SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 81: Mini Displayport

    Output Ground ML_Lane3- DP data 3- Output CONFIG1 CAD Cable Adapter Detect Input CONFIG2 Ground (pull-down) AUX_CH+ Auxiliary channel+ Bi-directional Ground AUX_CH- Auxiliary channel- Bi-directional Hot Plug Detect Input Ground DP_PWR +3.3V (fused) Output SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 82: Rj45 Ethernet

    The pins of a 3.5 mm jack are assigned as follows depending on the audio device: Ring 1 Ring 2 Sleeve Headphone out (stereo) Line out (stereo) Line in (stereo) Microphone in (mono) Headset (OMTP) Headset (CTIA) SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 83: System Resources

    Setup parameters may not be included, depending on your order. The interface of your BIOS Setup can deviate from the figures in this document. You can find a detailed description of the BIOS on the Support website under Entry ID: 92189178 (http://support.automation.siemens.com/WW/view/en/92189178). SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 84: Keyboard Inputs For The Bios

    1. Reset the device (warm or cold restart). Depending on the device version, the default settings can differ from the figures shown. The following message appears briefly on the display at the end of the self-test: Press ESC for boot options SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 85 BIOS or the operating system. Start BIOS Setup via Setup Configuration Utility BIOS Update Update BIOS from USB flash drive MEBx Intel Management Engine AMT configuration Available as of Windows 8 or later SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 86: Structure Of The Bios Setup Menu

    Determine boot options, e.g., boot order Exit Save and exit (see Exit menu) The menus always have the same structure. The figure below shows an example for the "Main" menu. Device-specific information is shown blurred. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 87 Short help texts on the currently selected setup parame- ters are displayed in the center right-hand area. ⑤ Key assignment The key assignment for navigation in the BIOS Setup is found in the footer. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 88: Exit Menu

    Requirement: The parameters are saved prior to this with "Save Custom Defaults". Save Custom Defaults The currently configured Setup parameters are saved as a custom profile (see also "Load Custom Defaults"). Discard Changes All changes are discarded. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 89: Default Bios Setup Entries

    Defaults Custom entries System Time hh:mm:sss System Date MM/TT/JJJJ Advanced System parameters Defaults Custom entries HPET- HPET Support Enabled Advanced > Boot Configuration System parameters Defaults Custom entries NumLock POST Errors All without keyboard SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 90 Intel AMT Setup Prompt Enabled MEBx Selection Screen Disabled Un-Configure ME Disabled Intel AMT Configuration Screens Enabled USB Configure Disabled Intel AMT Password Write Enabled USB Configure Disabled PET Progress Enabled Intel AMT SPI Protected Disabled SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 91 Active Processor Cores Hyper-Threading Enabled Enabled Power > Power & Performance > CPU - Power Management Control System parameters Defaults Custom entries Intel (R) SpeedStep (tm) Enabled Intel (R) Speed Shift Technology Disabled SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 92 Enabled Timeout Boot > Boot Device Priority System parameters Defaults Custom entries Normal Boot Menue Normal Boot > Boot Type Order System parameters Defaults Custom entries Hard Disk Drive Micron_M600_MTFDDAV128MBF (example) SIEMENS USB-FD 4 SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 93: Bios Update

    BIOS update Check regularly if updates are available for download to your device. You can find additional information on the Internet at the following address: After Sales Information System (http://www.siemens.com/asis). Noting down and restoring BIOS Setup settings NOTICE Irretrievable loss of data All BIOS Setup settings are deleted after the BIOS update.
  • Page 94 There may be several reboots after a BIOS update. These reboots are initiated by the Management Engine (ME). The reboots are required by the ME to adapt itself to the changes of the BIOS update. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 95: Alarm, Error And System Messages

    Check the CMOS clock. Keyboard error Function keys are defective PLD configuration failed Programming of the PLC on the motherboard has failed. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 96: Active Management Technology (Amt)

    SIMATIC IPC with Intel® AMT from it. The following figure shows remote maintenance of SIMATIC IPCs with Intel® AMT, e.g. for troubleshooting a corrupt operating system or incorrect BIOS settings: SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 97: Overview Of Amt

    6. Only for the devices IPC547D, IPC547E and IPC547G: Select the "Normal" setting for "MEBx Mode". 7. Exit the BIOS Setup with key (Save and Exit). Only for the devices IPC547D, IPC547E and IPC547G: Exit the BIOS Setup with key. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 98 6. Switch to the "Intel(R) ME General Settings" submenu and enable access via the network with "Activate Network Access". 7. Confirm the dialogs that appear with "Y". Drivers are automatically installed once with the Windows system start in the subsequent restart. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 99: Reset Intel® Amt To Default Settings With Un-Configure

    1. You can obtain the address of the AMT server in the command line in Windows using "ipconfig" and in UNIX using "ifconfig". If the AMT server and operating system do not use the same network address, ask your network administrator for the address you have been assigned. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 100: Forcing User Consent

    2. Select the value "KVM" for "User Consent". To allow a user with administrator privileges to avoid this code query, follow these steps: 1. Select "Intel(R) AMT Configuration > User Consent" in the MEBx. 2. Select "Opt-in Configurable from Remote IT". SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 101: Technical Support

    You can find additional information and support for the products described on the Internet at the following addresses: ● Technical support (https://support.industry.siemens.com) ● Support request form (http://www.siemens.com/automation/support-request) ● After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) ● SIMATIC Documentation Collection (http://www.siemens.com/simatic-tech-doku-portal) ● Your local representative (http://www.automation.siemens.com/mcms/aspa- db/en/Pages/default.aspx)
  • Page 102: Troubleshooting

    An ISO image mounted with Booting from USB is disa- Enable booting from USB in the BIOS Setup, see section Intel® AMT does not boot bled in the BIOS "Default BIOS Setup entries (Page 89)", "Boot" section. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 103: Problems With Wlan

    For the best performance, a line-of-sight connection of the network components is preferred. – A high load on the network, perhaps from too many simultaneous access attempts from different nodes, can lead to lower data rates or communication problems. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 104 Technical Support A.2 Troubleshooting SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 105: Labels And Symbols

    Opening for Kensington lock opening Attention ESD (Electrostatic sensitive Warning of hot surface device) Operator controls Symbol Meaning Symbol Meaning On/off switch, without electrical isola- Eject CD/DVD tion On/off switch, without electrical isola- tion SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 106: Certificates, Approvals And Markings

    CE markings for European countries Marking of Federal Communications Commission for the USA EFUP (Environment Friendly Use Approved for Korea Period) marking for China Test mark of the Underwriters La- Disposal information, observe the boratories local regulations. SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 107: Interfaces

    DVI-D interface Line In LAN interface, not approved for con- Line Out necting WAN or telephone Serial port Microphone input USB port Universal Audio Jack USB 2.0 high-speed port Headphone output USB 3.0 super-speed port SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 108 Labels and symbols B.5 Interfaces SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 109: C.1 Abbreviations

    Computer network that is limited to a local area. Liquid Crystal Display Liquid crystal display LEDs Light Emitting Diode Light emitting diode MLFB Machine-readable product designation Order number Multi Media Card Memory card of the format 32 mm x 24.5 mm SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 110 Intel technology with which a virtually closed environment can be made available. VT-D Virtualization Technology for Directed I/O Enables the direct assignment of a device (e.g. network adapter) to a virtual device. WLAN Wireless LAN Wireless local area network SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 111: Index

    COA label, 30 Connection at device, 14 COM1 Connection to docking station, 20 Pin assignment of the interface, 80 Pin assignment of the interface, 82 COM1 port, 76 Technical specifications of interface, 76, 77 SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 112 Function, 17 UAJ, in assignment of the audio jack, 82 Pos., 13 USB 3.0 Type A, 14, 20 Switch off the device., 39 USB 3.0 Type A, pin assignment, 78 Online ordering system, 48 SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 113 For the USA and Canada, 37 Repair service, 57, 57 Switch off screen, (Operating mode) Repairs, 24 System LEDs, (Status displays) Restore function, 59 System partition, 60 RFID reader System resources, 83 Pos., 13 using, 47 SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...
  • Page 114 Pin assignment of the interface, 78 USB Type C Pin assignment of the interface, 79 Using rechargeable batteries, 54 Ventilation slots, 14, 14 Weight, 73 Windows Installing, 62 Partitions, (Partitions) Wireless LAN, 48, 51 Regulations, 69 WLAN Standard, 76 SIMATIC ITP1000 Operating Instructions, 05/2017, A5E37340160-AB...

Table of Contents